SLM-3650 Satellite Modem
Revision 3
Options
MN/SLM3650.IOM
A–5
A.1.2.3 Entering
Access
Codes from the Front Panel
Step
Procedure
1
Press CLEAR to return to Main menu.
2
Use the [
←
] [
→
] keys to go to the Function Select: Utility menu.
3 Press
<ENTER>.
4
Go to Utility: Modem Type menu.
5 Press
<ENTER>.
6
Go to Configuration Code-Modem menu.
7 Press
<ENTER>.
8
Menu should display as follows:
1) AAAAAAAAAA
2) AAAAAAAAAA
9
To enter the code, press <ENTER> and use the [
↑
] [
↓
] keys to select an alpha numeric character.
Use [
→
] to move to the next character or to move to the next line. Repeat this procedure until all 20
characters of the code have been entered.
10
After completing entry of the 20-character code, press <ENTER>. The unit should display Modem
Initialization and will reboot to the factory default settings with the new option available.
11
If a wrong or invalid code is entered, the unit will display Wrong Code Entered! and no changes will
occur. Retry the code, verify that the code is correct, or request assistance from Comtech EF Data
Customer Support.
A.1.2.4
Entering Access Codes from the Remote Control Port
Step
Procedure
1
Establish remote communication with the unit. Display will show REMOTE MODE
(if applicable).
2
Enter the following commands as needed to enable the option related to each board:
3
The modem should re-initialize and boot up to the factory default settings.
Note: If the unit is an SDR-54/54A, the power should be cycled to re-initialize the unit and enable the
option(s).
Main Board:
<x/CCMD_code
Overhead board:
<x/CCOD_code
Mux/Demux Board:
<x/CCMX_code
TX-Reed-Solomon:
<x/CCTR_code
RX-Reed-Solomon:
<x/CCRR_code
x = address
code = 20 digit configuration code