SLM-3650 Satellite Modem
Revision 3
Operation
MN/SLM3650.IOM
3–24
ASYNC RX BAUD
Programs the ASYNC overhead receive baud rate for 110 to 38400 bit/s.
Upon entry, the current status of the ASYNC RX baud rate is displayed. Press [
↑
] or [
↓
] key
to select one baud rate. Press [ENTER] to execute the change.
Conditional:
The menu is only available when the
Function Select: Utility: Modem Type
=
ASYNC and requires that the Overhead Card is installed.
ASYNC TX LENGTH
Programs the ASYNC overhead transmit word length for 5, 6, 7, or 8 bits.
Upon entry, the current status of the ASYNC TX word length is displayed. Press [
↑
] or [
↓
] to
make the selection. Press [ENTER] to execute the change.
Conditional:
The menu is only available when the
Function Select: Utility: Modem Type
=
ASYNC and requires that the Overhead Card is installed.
ASYNC RX LENGTH
Programs the ASYNC overhead receive word length for 5, 6, 7, or 8 bits.
Upon entry, the current status of the ASYNC RX word length is displayed. Press [
↑
] or [
↓
] to
make the selection. Press [ENTER] to execute the change.
Conditional:
The menu is only available when the
Function Select: Utility: Modem Type
=
ASYNC and requires that the Overhead Card is installed.
ASYNC TX STOP
Programs the ASYNC overhead transmit stop bits for 1 or 2.
Upon entry, the current status of the ASYNC TX stop bits is displayed. Press [
↑
] or [
↓
] to
make the selection. Press [ENTER] to execute the change.
Conditional:
The menu is only available when the
Function Select: Utility: Modem Type
=
ASYNC and requires that the Overhead Card is installed.
ASYNC RX STOP
Programs the ASYNC overhead receive stop bits for 1 or 2.
Upon entry, the current status of the ASYNC RX stop bits make the selection. Press [ENTER]
to execute the change.
Conditional:
The menu is only available when the
Function Select: Utility: Modem Type
=
ASYNC and requires that the Overhead Card is installed.