SLM-3650 Satellite Modem
Revision 3
Operation
MN/SLM3650.IOM
3–27
3.4.4
Function Select: Configuration: Local AUPC
Conditional:
This menu is displayed when the Local Modem AUPC = ON located under
the
Function Select: Utility: Modem Type
menu. Refer to Figure 3-7.
AUPC ENABLE
Programs the AUPC ON or OFF.
Upon entry, the current status is displayed. Press [
↑
] or [
↓
] to make the selection. Press [ENTER]
to execute the change.
NOMINAL POWER
Programs the nominal power value of the AUPC. The nominal power value can range from -5 to -30
dBm, in 0.5 dBm steps.
Upon entry, the current nominal power value is displayed. Press [
↑
] or [
↓
] to increment or
decrement the digit at the flashing cursor. Press [ENTER] to execute the change.
MINIMUM POWER
Programs the minimum power level of the AUPC. The minimum power level can range from -5 to -
30 dBm, in 0.5 dBm steps.
Upon entry, the current minimum power level is displayed. Press [
↑
] or [
↓
] to increment or
decrement the digit at the flashing cursor. Press [ENTER] to execute the change.
MAXIMUM POWER
Programs the maximum power level of the AUPC. The maximum power level can range from -5 to -
30 dBm, in 0.5 dBm steps.
Upon entry, the current maximum power level is displayed. Press [
↑
] or [
↓
] to increment or
decrement the digit at the flashing cursor. Press [ENTER] to execute the change.
TARGET NOISE
Programs the Eb/N0 target set point. The Eb/N0 target set point ranges from 3.2 to 16.0 dB, in 0.1
dB steps.
Upon entry, the current Eb/N0 target set point is displayed. Press [
↑
] or [
↓
] to increment or
decrement the digit at the flashing cursor. Press [ENTER] to execute the change.
TRACKING RATE
Programs the maximum tracking rate of the AUPC.
Maximum tracking rate can range from 0.5 to 6.0 dBm/minute, in 0.5 dBm/minute steps.
Upon entry, the current maximum tracking rate is displayed. Press [
↑
] or [
↓
] to increment or
decrement the digit at the flashing cursor. Press [ENTER] to execute the change.
LOCAL CL ACTION
Programs the local carrier loss for HOLD, NOMINAL, or MAXIMUM.
Upon entry, the current status of the local carrier loss is displayed. Press [
↑
] or [
↓
] to make the
selection. Press [ENTER] to execute the change.
REMOTE CL ACTION
Programs the remote carrier loss for HOLD, NOMINAL, or MAXIMUM.
Upon entry, the current status of the remote carrier loss is displayed. Press [
↑
] or [
↓
] to make the
selection. Press [ENTER] to execute the change.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com