SLM-3650 Satellite Modem
Revision 3
Options
MN/SLM3650.IOM
A–9
Table A-2. D&I Specifications (Continued)
Parameter
Specification
Buffer Depth
T1, T1_ESF, E1_CCS,
1, 2, 4, 8, 16, or 32 ms
E1_IBS, E1_31_TS
E1_CAS
7.5, 15, or 30 ms
T1_IBS
6, 12, 18, 24, or 30 ms
Depth Status
Monitored accurate to 1%
Buffer Centering
Automatic (start of service), manual
Overflows/Underflows
Logged as stored fault
Engineering Service Channel
ESC Data Interface Type
EIA-232
ESC Data Rate
(Maximum Asynchronous)
1/2000 of satellite data rate, maximum (over sampled)
ESC Data Circuits Supported
SD, RD, DSR
Faults and Alarms
Backward Alarms Supported
1 (looped per IESS-309)
Backward Alarm Output
Sums into secondary alarm
Modulator Fault
Open collector, 15V maximum, 20 mA maximum, used by protection
switch, if in system
Demodulator Fault
Open collector, 15V maximum, 20 mA maximum, used by protection
switch, if in system
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com