SLM-3650 Satellite Modem
Revision 3
Installation
MN/SLM3650.IOM
2-11
Notes:
1. IDR configuration connector pinouts:
a. Backward alarm relay contacts are named for normal no fault conditions
(BWOx-C connected to BWOx-NC if no fault).
b. Backward alarm inputs should be grounded or pulled logic low to clear
the alarm.
c. Signals MF, DF, and DMA are open-collector, high-impedance (if
faulted). MF and DF are used by a backup protection switch if the
modem is used in a redundant system.
d. Relay contacts DF-C and DF-NO are named for faulted condition (DF-
C connected to DF-NO, unless demodulator [Demod] fault).
2. D&I/ASYNC interface connector pinouts:
a. With regard to alarm relay contacts, COMM is connected to NO when
there is no fault. COMM is connected to NC in a faulted condition.
b. Signals MF, DF, and DMA are open-collector, high-impedance (if
faulted). MF and DF are used by a backup protection switch if the
modem is used in a redundant system.
3. The 50-pin connector requires a breakout panel for the external connections
between the modem and terrestrial equipment.