SLM-3650 Satellite Modem
Revision 3
Installation
MN/SLM3650.IOM
2-7
2.3.2
Fault Connector and Pinouts (J7)
The fault connector provides Form C contact closures for fault reporting. The three Form C
summary fault contacts are Modulator, Demodulator, and Common Equipment.
The fault interface connection is a 9-pin female D connector (J7) located on the rear panel
of the modem. Screw locks are provided for mechanical security on the mating connector.
Refer to Table 2-3 for pinout information.
Table 2-3. Fault Connector and Pinouts (J7)
Pin #
Signal Function
Name
1
Common equipment is not faulted
NO
2
COM
3
Common equipment is faulted
NC
4
Modulator is not faulted
NO
5
COM
6
Modulator is faulted
NC
7
Demodulator is not faulted
NO
8
COM
9
Demodulator is faulted
NC
Note:
A connection between the common (COM) and normally open (NO)
contacts indicates no fault.
Refer to Chapter 5 for a discussion of monitored faults. To obtain a system summary
fault, connect all the Form C contacts in parallel.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com