SLM-3650 Satellite Modem
Revision 3
Maintenance
MN/SLM3650.IOM
5–2
5.1.1 Interface
Checkout
Use the following procedure and the test setup in Figure 5-1 to inspect the interface.
Figure 5-1. Fault Isolation Test Setup
1. Connect a BER test set to the appropriate modem data connector as shown in
Figure 5-2. Refer to Chapter 2 for external modem connections.
2. Set up the modem for baseband loopback operation by using the Configuration
Interface front panel menu (Chapter 3). The modem will run error free. Refer to
Chapter 3 for a block diagram of the baseband loopback operation.
3. Change the modem from baseband loopback to interface loopback operation by
using the Configuration Interface front panel menu (Chapter 3). The modem will
run error free. Refer to Chapter 3 for a block diagram of the interface loopback
operation.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com