SLM-3650 Satellite Modem
Revision 3
Installation
MN/SLM3650.IOM
2-19
2.3.5
Alarms Connector and Pinouts (J10)
The alarms connector provides Form C contact closures for alarm reporting. The two
Form C summary fault contacts are Modulator and Demodulator.
The alarms connection is a 9-pin female D connector (J10) located on the rear panel of the
modem. Screw locks are provided for mechanical security on the mating connector. Refer to
Table 2-11 for pinout information.
Table 2-11. Alarms Connector and Pinouts (J10)
Pin #
Signal Function
Name
1
Alarm 1 is faulted
NO
2
COM
3
Alarm 1 is not faulted
NC
4
Alarm 2 is faulted
NO
5
COM
6
Alarm 2 is not faulted
NC
7
Alarm 3 is faulted
NO
8
COM
9
Alarm 3 is not faulted
NC
•
Alarm 1 = Not used
•
Alarm 2 = TX
•
Alarm 3 = RX
Refer to Chapter 5 for a discussion of monitored alarms. To obtain a system summary