SLM-3650 Satellite Modem
Revision 3
Options
MN/SLM3650.IOM
A–34
A.1.4.5.4
Configuration #4 (Local EIA-485 [4-Wire] to Remote EIA-232)
Table A-8. Local EIA-485 (4-Wire) to Remote EIA-232
#4. Local End Modem Settings for EIA-485 (4-Wire)
Utility: Interface Menu
ASYNC TX and RX Type
EIA-485 (4-wire)
Configuration: Interface Menu
ASYNC TX and RX Baud Rate
110 to 38400
(See A.1.4.3.10)
ASYNC TX and RX Length
7 bits
ASYNC TX and RX Parity
Even
ASYNC TX Stop
2 bits
#4. Remote End Modem Settings for EIA-232
Utility: Interface Menu
ASYNC TX and RX Type
EIA-232
Configuration: Interface Menu
ASYNC TX and RX Baud Rate
150 to 38400
(See A.1.4.3.10)
ASYNC TX and RX Length
7 bits
ASYNC TX and RX Parity
Even
ASYNC TX Stop
2 bits
Utility: System Menu
Remote Baud Rate
Equal to ASYNC TX and RX baud rate
Parity Even
Address
1 to 255
The local end cable connects the 25-pin female ASYNC connector (on either the
breakout panel or the Y cable) to the EIA-485 (4-wire) remote terminal (WYSE or laptop
computer). The pinout of the local cable is listed in the following table.
#4. Local End EIA-485 (4-Wire) Twisted Pair
9-Pin
Female Connector
25-Pin
Male Connector
TX+ 4 14
TX+
TX- 5 2 TX-
RX+ 8 16
RX+
RX- 9 3 RX-
The remote end cable connects the 25-pin female ASYNC connector (on either the
breakout panel or the Y cable) to the 9-pin female connector, J6, at the rear of the
modem. The pinout of the remote cable is listed in the following table.
#4. Remote End EIA-232
9-Pin
Male Connector
25-Pin
Male Connector
RX 2 2
RX
TX 3 3
TX
GND 5 7
GND
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com