3.4.10.4
Function Select: Receive Interface: Faults
BUFFER UNDERFLOW
Buffer underflow alarm. Indicates that a buffer underflow has occurred.
BUFFER OVERFLOW
Buffer overflow alarm. Indicates that a buffer overflow has occurred.
RX DATA/AIS
Data or AIS. When data fault is selected in the
Function Select:
Configuration Interface
menu (Figure 3-6), the fault indicates a data stable
condition. This indicates the data coming from the satellite is all 1s or 0s (i.e.,
data is not transitioning). When AIS is selected, the Alarm indicates the data is
all 1s from the satellite. When None is selected in the Configuration Interface
menu, the RX Data/AIS Fault/Alarm is not activated.
Note:
AIS is an alarm, not a switching fault.
FRAME BER
Frame BER fault. Indicates that the frame BER exceeds 1-3.
BACKWARD ALARM
Backward alarms.
BUFFER CLK PLL
Buffer clock phase-locked loop fault. Indicates the buffer clock PLL is not
locked.
BUFFER CLK ACT
Activity detector alarm of the selected interface receive clock. The interface
will fall back to the satellite clock when this fault is active.
DEMUX LOCK
DEMUX lock fault. Indicates that the DEMUX is not locked.
RX 2047 LOCK
RX 2047 lock alarm. Indicates the RX 2047 data pattern is not locked.
Note:
This alarm is only active if RX 2047 is ON.
BUFFER FULL
Buffer full alarm. Indicates the buffer is less than 10% or greater than 90% full.
RX INSERT
Insert interface hardware fault. Typically indicates the insert interface PLL is
not locked. This fault is only available when D&I is selected for modem type.
RX AUDIO 1 CLIP
IDR RX audio for channel 1 is clipped.
RX AUDIO 2 CLIP
IDR RX audio for channel 2 is clipped.
CONFIGURATION Configuration
alarm