Appendix
C
Server Error Messages
The following POST error message is new to the Compaq ProLiant ML330
Generation 2 server:
Table C-1
POST Error Message
Error Code
Audible
Beeps
Probable Source of
Problem
Action
A processor thermal
event occurred prior
to this power up,
Processor
X
None
Processor
X
(1 or 2)
has reached an
excessive temperature
and has stopped
operation
Verify the following information:
■
The heatsink is properly installed.
■
Server fans are properly installed
and working.
■
Ambient temperature is within an
acceptable range.
See Appendix F, “Specifications,” for
operational temperature requirements.
For a complete listing of error messages, refer to the
Compaq Servers
Troubleshooting Guide.