CompAir UK Ltd.
5280D Compressor Publication 98407.1440
Page 11
1440.doc
5. OPERATION
PRECAUTIONS (Cont.)
•
If there is any indication that the compressor is
overheating it must be shut-down. (A high air or
gas temperature switch is fitted as standard to
guard against operating with excessive
temperature). Beware of burns from hot oil and
water when working on a unit recently shut-down.
•
Do not operate the unit when guards provided for
protection for all rotating and reciprocating parts
have been removed for essential maintenance.
Secure guards following any servicing or repair.
•
Local noise regulations must be observed. Ear
defenders are suggested by Noise at Work
Regulations 1989 when the level is greater than
85 dB A at one meter. Be aware high noise levels
can interfere with communication.
6.
MAINTENANCE & REPAIR
PRECAUTIONS
•
Maintenance repair and modifications must be
carried out by competent persons under qualified
supervisor.
•
The compressor will have a preserving oil applied
to interior surfaces (Oil lubricated models). Oil
free models will have desiccant bags in valve
covers and distance pieces.
•
Handling components such as seals, gaskets and
diaphragms should not present a personnel
hazard. Preservation oils again should not
present a personnel hazard if handled under
normal handling practices.
•
Whilst compressors are asbestos free, treat all
damaged gaskets as asbestos - when the
Asbestos at work regulations apply.
•
Viton 'O' seals under normal operating conditions
are safe.
•
However, should there be a fire within the
compressor or these seals are likely to exceed a
temperature of 300°C the material will
decompose.
•
Degraded Viton gives off Hydrogen Fluoride
fumes and if in contact with the skin an acid
formed causes severe burns.
•
If Viton seals appear charred or gummy
do not
touch with unprotected hands: use neoprene or
PVC gloves.
•
Wash the area with lime water and avoid
breathing any fumes. If contamination of the skin
occurs was with lime water and seek medical
advice.
Pre-Maintenance Operation
•
1. Isolate the compressor from the main electrical
supply. Lock the isolator in the OFF position and
remove fuses.
•
2. Attach a label
" WORK IN PROGRESS - DO
NOT APPLY VOLTAGE"
.
•
3. Close the isolating valve between the
compression unit and user's pipework. Close the
isolating valve in the cooling water inlet pipe.
Attach a label
"WORK IN
PROGRESS - DO NOT
OPEN".
•
4. Check that all pressurised gas trapped in the
system is released to atmosphere or safely to gas
storage. Check that all pressure gauges register
zero.
•
5. Ensure that the cooling water system has been
drained.
•
6. Check that the drain valve on the delivery
manifold is clear and gas pressure has been
released.
•
7. Check that all interstage drains are open to
ensure any gas trapped between stages has
been released.
•
Stand clear of all valve covers when removing the
securing screws.
•
When removing valve covers for valve
replacement, ensure a minimum of two threads
are left engaged on the valve cover securing
screws. Lever the valve cover until the 'O' seal is
disengaged from the port in the cylinder head.
Remove the securing screws and take out valve
cover.
•
Use only lubricating oils and greases
approved by CompAir UK Ltd to avoid
potential hazards especially the risk of
explosion or fire and the possibility of
decomposition or generation of hazardous
gases.
•
Always clean oil spills from the
surrounding floor
before and after maintenance work.
Содержание 5280D.1.IAC
Страница 3: ...DATE REMARKS DATE REMARKS logsheet5280 d...
Страница 9: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 6 1440 doc...
Страница 29: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 26 1440 doc...
Страница 33: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 30 1440 doc...
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 36 1440 doc...
Страница 44: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 38 1440 doc CRANKCASE 1...
Страница 46: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 40 1440 doc CRANKCASE 2...
Страница 48: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 42 1440 doc CRANKCASE 3...
Страница 50: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 44 1440 doc CYLINDER 1st STAGE...
Страница 52: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 46 1440 doc SUCTION VALVE COVER...
Страница 54: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 48 1440 doc DELIVERY VALVE COVER 1st STAGE...
Страница 58: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 52 1440 doc CRANKSHAFT CONNECTING ROD...
Страница 60: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 54 1440 doc CROSSHEAD 1st STAGE...
Страница 62: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 56 1440 doc PISTON 1st STAGE...
Страница 64: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 58 1440 doc GLAND 1st STAGE...
Страница 66: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 60 1440 doc OIL PUMP...
Страница 68: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 62 1440 doc OIL PUMP FILTER...
Страница 70: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 64 1440 doc INTERCOOLER...
Страница 72: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 66 1440 doc 1st STAGE PIPE WORK...
Страница 74: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 68 1440 doc...
Страница 76: ......
Страница 77: ......
Страница 78: ......
Страница 79: ......
Страница 80: ......
Страница 81: ......
Страница 82: ......
Страница 83: ......
Страница 84: ......
Страница 85: ......
Страница 86: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 70 1440 doc...
Страница 87: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 71 1440 doc Appendix 4 Service Plan...
Страница 94: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 72 1440 doc...
Страница 98: ...App 408 Customer PET controller installation guide user s manual Page 2 App 408C 98155 1015...
Страница 120: ...CompAir UK Ltd APP 004 ANTI VIBRATION MOUNTS Page 2 app004 doc...
Страница 122: ...CompAir UK Ltd PUBLICATION APP070 PRESSURE GAUGES GENERAL Page 2 app070 doc...
Страница 128: ...CompAir UK Ltd PUBLICATION APP 138 3 WAY SOLENOID VALVES PS2197 Page 2 app138 doc...
Страница 130: ...CompAir UK PUBLICATION APP034 ELECTRIC MOTOR MAINTENANCE GENERAL Page 2 APP034 doc...
Страница 133: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 74 1440 doc...