background image

Description

Portable oilless air compressors are for 
home and workshop use. Cleaning or 
replacement of the inlet filter on all 
models and draining moisture from the 
air receivers are required maintenance. 

Safety Guidelines

This manual contains information 
that is very important to know 
and understand. This information 
is provided for SAFETY and to 
PREVENT EQUIPMENT PROBLEMS. 
To help recognize this information, 
observe the following symbols. 

 

Danger indicates 

  an imminently 

hazardous situation which, if not 
avoided, WILL result in death or serious 
injury.
 

Warning indicates 

  a potentially 

hazardous situation which, if not 
avoided, COULD result in death or 
serious injury.
 

Caution indicates 

  a potentially 

hazardous situation which, if not 
avoided, MAY result in minor or 
moderate injury.
 

Notice indicates 

  important 

information, that if not followed, may 
cause damage to equipment.

Unpacking

When unpacking unit, inspect carefully 
for any damage that may have occurred 
during transit. Make sure any loose 
fittings, bolts, etc., are tightened before 
putting unit into service. In case of 
questions, damaged or missing parts, 
please call 1-800-543-6400 for customer 
assistance. Have the serial number, 
model number, and parts list (with 
missing parts circled) before calling.

Do not retUrn  
the proDUct to  
the retailer!

 

Do not operate unit  

  if damaged during 

shipping, handling or use. Damage may 
result in bursting and cause injury or 
property damage.

reaD & Follow all inStrUctionS

Save theSe inStrUctionS

Do not DiScarD

STOP!

200 pSi portable aSMe 

air compressors

Breathable Air Warning

this compressor / pump is not 
equipped and should not be 
used “as is” to supply breathing 
quality air. For any application of 
air for human consumption, the 
air compressor / pump will need 
to be fitted with suitable in-line 
safety and alarm equipment. 
this additional equipment is 
necessary to properly filter 
and purify the air to meet 
minimal specifications for Grade 
D breathing  as described in 
compressed Gas association 
commodity Specification G 
7.1 - 1966, oSha 29 cFr 1910. 
134, and / or canadian Standards 
associations (cSa).

DiSclaiMer oF warrantieS
in the event the compressor is 
used for the purpose of breathing 
air application and proper in-line 
safety and alarm equipment is 
not simultaneously used, existing 
warranties shall be voided, and 
the campbell hausfeld disclaims 
any liability whatsoever for any 
loss, personal injury or damage.

Record the Model No., Serial No. and 
date of purchase in the space below.
Model No.  ______________________
Serial No. 

______________________

Date of purchase  _________________

Retain these numbers for future 

reference.

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. 
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or 
property damage! Retain instructions for future reference.

See warranty on page 8 for important information about commercial use of this product.

operating instructions 

hG3000 Series, hJ3001 Series, hJ3002 Series

REMINDER: Keep your dated proof of purchase for warranty purposes! 

Attach it to this manual or file it for safekeeping.

IN634100AV 7/10

© 2010 Campbell Hausfeld/Scott Fetzer

For parts, product & service information, 

visit 

www.chpower.com

Содержание HG3000 Series

Страница 1: ...is compressor pump is not equipped and should not be used as is to supply breathing quality air For any application of air for human consumption the air compressor pump will need to be fitted with suitable in line safety and alarm equipment This additional equipment is necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in Compressed Ga...

Страница 2: ...may allow it to turn on inadvertently To prevent this and possible damage from power surge turn to OFF position after each use 8 Release all pressures within system slowly dust and debris may be harmful Keep fingers away from a running compressor fast moving and hot parts will cause injury and or burns Disconnect power and depressurize system before servicing air compressor 9 Follow all local elec...

Страница 3: ... the spraying area as possible to minimize overspray accumulation on the compressor 5 When spraying or cleaning with solvents or toxic chemicals follow the instructions provided by the chemical manufacturer 6 Do not smoke when spraying paint insecticides or other flammable substances 7 Use a face mask respirator when spraying and spray in a well ventilated area to prevent health and fire hazards 8...

Страница 4: ...ressor is running indicating compressor is building pressure properly This gauge will show maximum pressure of compressor when it shuts off automatically at the pressure switch Drain Valve This valve is located underneath the tank Use this valve to drain moisture from the tank daily to reduce the risk of corrosion Drain liquid from tank daily Reduce tank pressure below 10 psi then drain moisture f...

Страница 5: ...whether the product is properly grounded Do not modify the plug provided if it does not fit the outlet have the proper outlet installed by a qualified technician This product is for use on a nominal 120V circuit and has a grounding plug similar to the plug illustrated in Figure 4 Only connect the product to an outlet having the same configuration as the plug Do not use an adapter with this product...

Страница 6: ...Valve Do not remove or attempt to adjust the safety valve Check the safety valve by performing the following steps 1 Plug the compressor in and run until shut off pressure is reached see Operating Procedure 2 Wearing safety glasses pull the ring on the safety valve see Figure 5 to release pressure from compressor tank Use your other hand to deflect fast moving air from being directed toward your f...

Страница 7: ...hen compressor shuts off 1 Loose connections fittings tubing etc 1 Check all connections with soap and water solution and tighten 2 Loose drain lock 2 Tighten 3 Check valve leaking 3 Disassemble check valve assembly clean or replace Do not disassemble check valve with air in tank bleed tank first Excessive moisture in discharge air 1 Excessive water in air receiver 1 Drain receiver 2 High humidity...

Страница 8: ...ssure switches e Drain cocks f Damage due to incorrect voltage or improper wiring g Other items not listed but considered general wear parts h Pressure switches air governors and safety valves modified from factory settings 2 Lubricated Compressors a Pump wear or valve damage caused by using oil not specified b Pump wear or valve damage caused by any oil contamination or by failure to follow prope...

Страница 9: ...r n est pas équipé pour et ne devrait pas être utilisé comme soi pour fournir de l air respirable Pour les applications d air pour la consommation humaine il est nécessaire d équiper le compresseur d air pompe avec de l équipement de sécurité en canalisation et d alarme Cet équipement additionnel est nécessaire pour filtrer et purifier l air afin d atteindre les spécifications minimales pour la re...

Страница 10: ... de faiblesse ou d usure et assurer que tous les raccordements sont sûrs ne pas utiliser si endommagé Contacter un centre de service autorisé pour l inspection ou la réparation Ne Pas faire fonctionner sans supervision Laisser le compresseur sur la position ON marche peut causer un démarrage accidentel Pour éviter un démarrage accidentel et de possibles dommages par surtension le mettre sur OFF ar...

Страница 11: ... produits inflammables 3 Utiliser un respirateur pendant la pulvérisation 4 Ne pas diriger la peinture ou autre matériel pulvérisé vers le compresseur Situer le compresseur aussi loin que possible de l endroit de pulvérisation pour réduire l accumulation de surpulvérisation sur le compresseur 5 Suivre les instructions du fabriquant pendant la pulvérisation ou le nettoyage avec des solvants ou prod...

Страница 12: ...le réservoir pendant le fonctionnement du compresseur ce qui confirme que le compresseur est en train d augmenter la pression de manière appropriée Ce manomètre indique la pression maximum du compresseur quand il s éteigne automatiquement à la pression limite Robinet de Purge Ce robinet se trouve sous le réservoir Utiliser cette soupape pour purger l humidité du réservoir quotidiennement afin de r...

Страница 13: ...isolant vert à l extérieur avec ou sans rayures jaunes est le fil de terre Ne pas utiliser d adaptateur de mise à la terre avec ce produit Ne jamais connecter le fil vert ou vert et jaune à une borne électrisé Consulter un électricien ou réparateur qualifié si vous ne comprenez pas toutes les instructions ou si vous n êtes pas certain que le produit est bien mis à la terre Ne pas modifier la fiche...

Страница 14: ...e pression de sortie dépassant la pression maximale indiquée de l accessoire Cycle marche arrêt du compresseur En position ON marche le compresseur pompe de l air dans le réservoir Lorsqu il atteint une pression d arrêt une coupure pré établie le compresseur s arrête automatiquement Si le compresseur reste en position ON marche et si l air sort complètement du réservoir en utilisant un mandrin de ...

Страница 15: ...ur du réservoir des canalisations d air et des ailettes de refroidissement de la pompe REMARQUE Il faut vérifier et nettoyer périodiquement le filtre à air dans le boîtier du filtre du côté de la tête et plus souvent s il est utilisé sous des conditions très poussièreuses ou lorsqu il y a beaucoup de brouillard créé par la pulvérisation et circulant près de l unité Important Le modèle doit être si...

Страница 16: ...bre dans la section de Installation 3 Clapet ou déchargeur défectueux 3 Remplacer ou réparer Le protecteur de surcharge thermique se déclenche souvant 1 Tension basse 1 Vérifier avec un voltmètre 2 Filtre d air obstrué 2 Nettoyer le filtre voir la section d Entretien 3 Ventilation insuffisante température de l endroit trop haute 3 Déménager le compresseur à un endroit bien ventilé 4 Calibre de fil...

Страница 17: ...17 Fr Série HG3000 Série HJ3001 Série HJ3002 Notes ...

Страница 18: ...n de fils incorrecte g Autres articles pas indiqués mais considérés pièces à fatigue générales h Manostats régulateurs d air et soupapes de sûreté qui ont étés modifiés d après les réglages de l usine 2 Compresseurs Graissés a Usure de la pompe ou dommage aux soupapes causé par l utilisation d huile non spécifiée b Usure de la pompe ou dommage aux soupapes causé par toute contamination d huile ou ...

Страница 19: ... compra con fecha para fines de la garantía Adjúntela a este manual o archívela en lugar seguro IN634100AV 7 10 2010 Campbell Hausfeld Scott Fetzer Compresores de Aire Portátiles ASME de 13 79 bar Por favor lea y guarde estas instrucciones Léalas cuidadosamente antes de tratar de montar instalar operar o dar mantenimiento al producto aquí descrito Protéjase usted mismo y a los demás observando tod...

Страница 20: ...er si están deterioradas o hay fugas Antes de usarlo cerciórese de que las conecciones estén bien apretadas y no lo use si encuentra irregularidades Notifíquele a un centro de servicio autorizado para que lo chequeen o reparen No lo haga funcionar sin supervisión El dejar el compresor en la posición ON encindido puede causar que se encienda inadvertidamente Para prevenir que eso ocurra y posibles ...

Отзывы: