background image

introduction

pressure Switch

 - ON/OFF Switch - In 

the ON position, the compressor shuts 
off automatically when tank pressure 
reaches the maximum preset pressure. 
In the OFF position, the compressor will 
not operate. This switch should be in 
the OFF position when connecting or 
disconnecting the power cord from the 
electrical outlet or when changing air 
tools.

regulator

 - The regulator controls the 

amount of air pressure released at the 
hose outlet.

aSMe Safety valve

 - This valve 

automatically releases air if the tank 
pressure exceeds the preset maximum.

exhaust tube

 - This tube carries 

compressed air from the pump to the 
check valve. This tube becomes very hot 
during use. To avoid the risk of severe 
burns, never touch the exhaust tube.

check valve

  - A one-way valve 

that allows air to enter the tank, but 
prevents air in the tank from flowing 
back into the compressor pump.

handle

 - Designed to move the 

compressor.

air outlet

 - A

 

quick connect coupler 

designed to work in combination with 
a quick connect plug to quickly and 
easily join a pneumatic tool to an air 
hose.

pressure Gauges

 - These gauges will 

show air pressure in the compressor 
tank and at the compressor outlet.

outlet pressure Gauge

 - Will show 

air pressure at the outlet in pounds per 
square inch (psi). Make sure this gauge 
reads ZERO (by adjusting regulator 
knob fully counterclockwise) before 
changing air tools or disconnecting air 
hose from outlet.

tank pressure Gauge

 - Will show air 

pressure in tank while the compressor 
is running, indicating compressor 
is building pressure properly. This 
gauge will show maximum pressure 
of compressor when it shuts off 
automatically at the pressure switch.

Drain valve

 - This valve is located 

underneath the tank. Use this valve to 
drain moisture from the tank daily to 
reduce the risk of corrosion.

 

Drain liquid from  

  tank daily.

Reduce tank pressure below 10 psi, 
then drain moisture from tank daily to 
avoid tank corrosion. Drain moisture 
from tank by opening the drain valve 
located underneath the tank.

installation

location

It is extremely important to install the 
compressor in a clean, well ventilated 
area where the surrounding air 
temperature will not be more than 
100°F.
A minimum clearance of 18 inches 
between the compressor and a wall is 
required because objects could obstruct 
air flow.

 

Do not locate the 

  compressor air inlet 

near steam, paint spray, sandblast areas 
or any other source of contamination. 
This debris will damage the motor

household use only. Store indoors.

electrical inStallation

 1.  Check and tighten all bolts, fittings, 

etc., before operating compressor.

 2.  Operate compressor in a ventilated 

area so that compressor may be 
properly cooled.

 3.  Compressor should be located 

where it can be directly plugged 
into an outlet, but if this is not 
possible, an extension cord may be 
used. It should be selected using the 
extension cord chart on page 5 as a 
guide.

 4.  To avoid loss of power and 

overheating, it is better to use 
additional air hose instead of 
extension cords to reach work area.

Figure 3

ASME Safety 
Valve

Pressure Switch

Tank Pressure 
Gauge

Outlet Pressure Gauge

Regulator

Air Outlet

4

Operating Instructions

www.chpower.com

Содержание HG3000 Series

Страница 1: ...is compressor pump is not equipped and should not be used as is to supply breathing quality air For any application of air for human consumption the air compressor pump will need to be fitted with suitable in line safety and alarm equipment This additional equipment is necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in Compressed Ga...

Страница 2: ...may allow it to turn on inadvertently To prevent this and possible damage from power surge turn to OFF position after each use 8 Release all pressures within system slowly dust and debris may be harmful Keep fingers away from a running compressor fast moving and hot parts will cause injury and or burns Disconnect power and depressurize system before servicing air compressor 9 Follow all local elec...

Страница 3: ... the spraying area as possible to minimize overspray accumulation on the compressor 5 When spraying or cleaning with solvents or toxic chemicals follow the instructions provided by the chemical manufacturer 6 Do not smoke when spraying paint insecticides or other flammable substances 7 Use a face mask respirator when spraying and spray in a well ventilated area to prevent health and fire hazards 8...

Страница 4: ...ressor is running indicating compressor is building pressure properly This gauge will show maximum pressure of compressor when it shuts off automatically at the pressure switch Drain Valve This valve is located underneath the tank Use this valve to drain moisture from the tank daily to reduce the risk of corrosion Drain liquid from tank daily Reduce tank pressure below 10 psi then drain moisture f...

Страница 5: ...whether the product is properly grounded Do not modify the plug provided if it does not fit the outlet have the proper outlet installed by a qualified technician This product is for use on a nominal 120V circuit and has a grounding plug similar to the plug illustrated in Figure 4 Only connect the product to an outlet having the same configuration as the plug Do not use an adapter with this product...

Страница 6: ...Valve Do not remove or attempt to adjust the safety valve Check the safety valve by performing the following steps 1 Plug the compressor in and run until shut off pressure is reached see Operating Procedure 2 Wearing safety glasses pull the ring on the safety valve see Figure 5 to release pressure from compressor tank Use your other hand to deflect fast moving air from being directed toward your f...

Страница 7: ...hen compressor shuts off 1 Loose connections fittings tubing etc 1 Check all connections with soap and water solution and tighten 2 Loose drain lock 2 Tighten 3 Check valve leaking 3 Disassemble check valve assembly clean or replace Do not disassemble check valve with air in tank bleed tank first Excessive moisture in discharge air 1 Excessive water in air receiver 1 Drain receiver 2 High humidity...

Страница 8: ...ssure switches e Drain cocks f Damage due to incorrect voltage or improper wiring g Other items not listed but considered general wear parts h Pressure switches air governors and safety valves modified from factory settings 2 Lubricated Compressors a Pump wear or valve damage caused by using oil not specified b Pump wear or valve damage caused by any oil contamination or by failure to follow prope...

Страница 9: ...r n est pas équipé pour et ne devrait pas être utilisé comme soi pour fournir de l air respirable Pour les applications d air pour la consommation humaine il est nécessaire d équiper le compresseur d air pompe avec de l équipement de sécurité en canalisation et d alarme Cet équipement additionnel est nécessaire pour filtrer et purifier l air afin d atteindre les spécifications minimales pour la re...

Страница 10: ... de faiblesse ou d usure et assurer que tous les raccordements sont sûrs ne pas utiliser si endommagé Contacter un centre de service autorisé pour l inspection ou la réparation Ne Pas faire fonctionner sans supervision Laisser le compresseur sur la position ON marche peut causer un démarrage accidentel Pour éviter un démarrage accidentel et de possibles dommages par surtension le mettre sur OFF ar...

Страница 11: ... produits inflammables 3 Utiliser un respirateur pendant la pulvérisation 4 Ne pas diriger la peinture ou autre matériel pulvérisé vers le compresseur Situer le compresseur aussi loin que possible de l endroit de pulvérisation pour réduire l accumulation de surpulvérisation sur le compresseur 5 Suivre les instructions du fabriquant pendant la pulvérisation ou le nettoyage avec des solvants ou prod...

Страница 12: ...le réservoir pendant le fonctionnement du compresseur ce qui confirme que le compresseur est en train d augmenter la pression de manière appropriée Ce manomètre indique la pression maximum du compresseur quand il s éteigne automatiquement à la pression limite Robinet de Purge Ce robinet se trouve sous le réservoir Utiliser cette soupape pour purger l humidité du réservoir quotidiennement afin de r...

Страница 13: ...isolant vert à l extérieur avec ou sans rayures jaunes est le fil de terre Ne pas utiliser d adaptateur de mise à la terre avec ce produit Ne jamais connecter le fil vert ou vert et jaune à une borne électrisé Consulter un électricien ou réparateur qualifié si vous ne comprenez pas toutes les instructions ou si vous n êtes pas certain que le produit est bien mis à la terre Ne pas modifier la fiche...

Страница 14: ...e pression de sortie dépassant la pression maximale indiquée de l accessoire Cycle marche arrêt du compresseur En position ON marche le compresseur pompe de l air dans le réservoir Lorsqu il atteint une pression d arrêt une coupure pré établie le compresseur s arrête automatiquement Si le compresseur reste en position ON marche et si l air sort complètement du réservoir en utilisant un mandrin de ...

Страница 15: ...ur du réservoir des canalisations d air et des ailettes de refroidissement de la pompe REMARQUE Il faut vérifier et nettoyer périodiquement le filtre à air dans le boîtier du filtre du côté de la tête et plus souvent s il est utilisé sous des conditions très poussièreuses ou lorsqu il y a beaucoup de brouillard créé par la pulvérisation et circulant près de l unité Important Le modèle doit être si...

Страница 16: ...bre dans la section de Installation 3 Clapet ou déchargeur défectueux 3 Remplacer ou réparer Le protecteur de surcharge thermique se déclenche souvant 1 Tension basse 1 Vérifier avec un voltmètre 2 Filtre d air obstrué 2 Nettoyer le filtre voir la section d Entretien 3 Ventilation insuffisante température de l endroit trop haute 3 Déménager le compresseur à un endroit bien ventilé 4 Calibre de fil...

Страница 17: ...17 Fr Série HG3000 Série HJ3001 Série HJ3002 Notes ...

Страница 18: ...n de fils incorrecte g Autres articles pas indiqués mais considérés pièces à fatigue générales h Manostats régulateurs d air et soupapes de sûreté qui ont étés modifiés d après les réglages de l usine 2 Compresseurs Graissés a Usure de la pompe ou dommage aux soupapes causé par l utilisation d huile non spécifiée b Usure de la pompe ou dommage aux soupapes causé par toute contamination d huile ou ...

Страница 19: ... compra con fecha para fines de la garantía Adjúntela a este manual o archívela en lugar seguro IN634100AV 7 10 2010 Campbell Hausfeld Scott Fetzer Compresores de Aire Portátiles ASME de 13 79 bar Por favor lea y guarde estas instrucciones Léalas cuidadosamente antes de tratar de montar instalar operar o dar mantenimiento al producto aquí descrito Protéjase usted mismo y a los demás observando tod...

Страница 20: ...er si están deterioradas o hay fugas Antes de usarlo cerciórese de que las conecciones estén bien apretadas y no lo use si encuentra irregularidades Notifíquele a un centro de servicio autorizado para que lo chequeen o reparen No lo haga funcionar sin supervisión El dejar el compresor en la posición ON encindido puede causar que se encienda inadvertidamente Para prevenir que eso ocurra y posibles ...

Отзывы: