Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. 
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or 
property damage! Retain instructions for future reference.

REMINDER: Keep your dated proof of purchase for warranty purposes! 

Attach it to this manual or file it for safekeeping.

IN633701AV 6/10

See Warranty on page 10 for important information about commercial use of this product.

Operating Instructions 

HU500000, HU502000

© 2010 Campbell Hausfeld/Scott Fetzer

For parts, product & service information, 

visit 

www.chpower.com

Oilless Compressors

Description

This residential oilless compressor is 
designed for do-it-yourselfers with a 
variety of home and automotive jobs. 
These compressors power spray guns, 
impact wrenches and other tools. 
Compressed air from this unit will 
contain moisture. Install a water filter 
or air dryer if application requires dry 
air.

Unpacking

After unpacking the unit, inspect 
carefully for any damage that may 
have occurred during transit. Make sure 
to tighten fittings, bolts, etc., before 
putting unit into service. In case of 
questions, damaged or missing parts, 
please call 1-800-543-6400 for customer 
assistance. Have the serial number, 
model number, and parts list (with 
missing parts circled) before calling.

DO nOt retUrn  
tHe prODUCt tO  
tHe retaIler!

 

Do not operate unit  

  if damaged during 

shipping, handling or use. Damage may 
result in bursting and cause injury or 
property damage.

reaD & FOllOW all InStrUCtIOnS

Save tHeSe InStrUCtIOnS

DO nOt DISCarD

Breathable Air Warning

this compressor / pump is not equipped and should not be used “as is” 
to supply breathing quality air. For any application of air for human 
consumption, the air compressor / pump will need to be fitted with 
suitable in-line safety and alarm equipment. this additional equipment 
is necessary to properly filter and purify the air to meet minimal 
specifications for Grade D breathing  as described in Compressed Gas 
association Commodity Specification G 7.1 - 1966, OSHa 29 CFr 1910. 
134, and / or Canadian Standards associations (CSa).

DISClaIMer OF WarrantIeS
In the event the compressor is used for the purpose of breathing air 
application and proper in-line safety and alarm equipment is not 
simultaneously used, existing warranties shall be voided, and the 
manufacturer disclaims any liability whatsoever for any loss, personal 
injury or damage.

STOP!

Record the Model No., Serial No. and date of purchase in the space 
below.
 

Model No. 

____________________

 

Serial No. 

____________________

 

Date of purchase 

____________________

Retain these numbers for future reference.

Содержание HU500000

Страница 1: ...lease call 1 800 543 6400 for customer assistance Have the serial number model number and parts list with missing parts circled before calling Do not return the product to the retailer Do not operate...

Страница 2: ...s in the United States the National Electrical Codes NEC and Occupational Safety and Health Act OSHA 3 Only persons well acquainted with these rules of safe operation should be allowed to use the comp...

Страница 3: ...he items marked with an asterisk were shipped loose with the unit 1 Wheel has an offset hub Place wheel insert into center of hub With offset hub facing axle iron assemble axle bolt through washer and...

Страница 4: ...om the tank daily to reduce the risk of corrosion Pressure Gauges These gauges will show air pressure in the compressor tank and at the compressor outlet Outlet Pressure Gauge Will show air pressure a...

Страница 5: ...ounded in accordance with all local codes and ordinances Overheating short circuiting and fire damage will result from inadequate wiring TEST RESET Figure 6 Grounding Method Grounded Outlet Grounding...

Страница 6: ...the tank Wear ANSI approved Z87 1 safety glasses 2 Drain moisture from tank by opening drain valve underneath tank Tilt tank to remove all moisture 3 Clean dust and dirt from tank air lines and pump...

Страница 7: ...rried from the tank through the hose and out of the gun as droplets mixed with the spray material Important This condensation will cause water spots in a paint job especially when spraying other than...

Страница 8: ...alve 3 Replace check valve Do not disassemble check valve with air pressure in tank bleed tank 4 Defective unloader valve on pressure switch 4 Replace unloader valve 5 Defective motor capacitor s 5 Re...

Страница 9: ...turdy wedge object to bring tank to level position 3 Cylinder or piston is worn scored 3 Replace or repair as necessary Compressor runs continuously and safety valve opens as pressure rises 1 Defectiv...

Страница 10: ...y d Electric motors check valves and pressure switches e Drain cocks f Damage due to incorrect voltage or improper wiring g Other items not listed but considered general wear parts h Pressure switches...

Страница 11: ...il Avoir en main le num ro de s rie num ro de mod le et liste de pi ces avec les pi ces manquantes encercl es avant d appeler NE PAS RENVOYER LE PRODUIT AU MARCHAND Ne pas utiliser un mod le qui a t e...

Страница 12: ...t OSHA 3 Seules les personnes bien familiaris es avec ces r glements d utilisation doivent tre autoris es se servir du compresseur 4 Garder les visiteurs l cart de et NE JAMAIS permettre les enfants d...

Страница 13: ...1 La roue a un moyeu d centr Placer la garniture de roue au centre du moyeu Avec le moyeu d centr face au fer d essieu assembler le boulon d essieu travers la rondelle puis les trous dans la roue et...

Страница 14: ...tte soupape pour purger l humidit du r servoir quotidiennement afin de r duire le risque de corrosion Manom tre s Ces manom tres indiquent la pression d air dans le r servoir du compresseur et la sort...

Страница 15: ...rodage Cette proc dure doit tre termin e avant d utiliser le compresseur pour la premi re fois Ensuite il n est pas n cessaire de la refaire 1 Ouvrir le robinet de vidange au bas du r servoir 2 Mettre...

Страница 16: ...et de vidange sous le r servoir Pencher le r servoir pour en retirer toute l humidit 3 Nettoyer la poussi re et la salet du r servoir des conduites d air et le couvercle de pompe tandis que le compres...

Страница 17: ...en forme de gouttelettes m lang e avec le mat riel utilis Important Cette condensation peut causer des taches d eau sur votre travail de peinture surtout pendant la pulv risation de peinture qui n est...

Страница 18: ...avec de l air dans le r servoir purger le r servoir 4 Soupape de d charge d fectueuse sur le manostat 4 Remplacer la soupape de d charge 5 Condensateur s de moteur d fectueux 5 Remplacer le condensat...

Страница 19: ...oir la position niveau 3 Le cylindre ou le piston est us marqu 3 Remplacer ou r parer au besoin Le compresseur fonctionne continuellement et la soupape de s curit s ouvre tandis que la pression monte...

Страница 20: ...nge r Dommage d la tension ou installation de fils incorrecte g Autres articles pas indiqu s mais consid r s pi ces fatigue g n rales h Manostats r gulateurs d air et soupapes de s ret qui ont t s mod...

Страница 21: ...1 800 543 8622 para obtener ayuda Tenga a mano el n mero de serie el n mero del modelo y la lista de partes con las partes que faltan marcadas con un c rculo antes de llamar NE PAS RENVOYER LE PRODUIT...

Страница 22: ...eguridad deben utilizar el compresor 4 Mantenga a los visitantes alejados y NUNCA permita la presencia de ni os en el rea de trabajo 5 Use anteojos de seguridad y prot jase los o dos para operar la un...

Страница 23: ...de la rueda en el centro del cubo Con el cubo descentrado hacia el hierro del eje instale el perno del eje a trav s de la arandela y de los orificios de la rueda y del hierro del eje 2 Coloque la ara...

Страница 24: ...resi n de aire en el tanque del compresor y a la salida del compresor Man metro de salida Indica la presi n de aire a la salida en libras por pulgada cuadrara bar psi Aseg rese de que este man mentro...

Страница 25: ...e este procedimiento antes de usar el compresor por primera vez Una vez completado no es necesario repetirlo 1 Abra la v lvula de drenaje que se encuentra en la parte inferior del tanque 2 Coloque el...

Страница 26: ...drenaje debajo del tanque Incline el tanque para eliminar toda la humedad 3 Limpie el polvo y la suciedad del tanque las l neas de aire y la cubierta de la bomba mientras el compresor contin a apagad...

Страница 27: ...ndo o rociando arena la humedad saldr del tanque mezclada con el material que est rociando ImportantE Esta condensaci n ocasionar manchas en la pintura especialmente cuando est pintando con pinturas q...

Страница 28: ...ula de retenci n desgastada 3 Cambie la v lvula de retenci n No desensamble la v lvula de retenci n con aire en el tanque purgue el tanque 4 V lvula de descarga defectuosa en el interruptor de presi n...

Страница 29: ...ivel 3 El cilindro o pist n est desgastado marcado 3 Reemplace o repare seg n sea necesario El compresor funciona en forma continua y la v lvula de seguridad se abre cuando aumenta la presi n 1 Presos...

Страница 30: ...s al alambrado incorrecto o conexi n a cicuitos con voltaje inadecuados para la unidad g Otros art culos no enumerados pero considerados de desgaste general h Presostatos controles de flujo de aire y...

Страница 31: ...Notes Notas Operating Instructions Instructions d Utilisation Manual de Instrucciones 31 HU500000 HU502000...

Страница 32: ...Operating Instructions Instructions d Utilisation Manual de Instrucciones Date Maintenance performed Repair components required Date Entretien ex cut l ments de remplacement requis Fecha Maintenimient...

Отзывы: