![Comelit VEDO10 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/comelit/vedo10/vedo10_technical-manual_2640394055.webp)
55
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.31.x.6.y.36 IP video expansion tamper
* Selected
1.1.1.31.x.6.y.42 Remote communications
tamper
* Selected
1.1.1.31.x.6.y.43 GSM concentrator jamming
* Selected
1.1.1.31.x.6.y.44 False code
* Selected
1.1.1.31.x.6.y.45 Zone Fault
* Selected
1.1.1.31.x.6.y.46 Siren fuse fault
* Selected
1.1.1.31.x.6.y.47 Radio control fault
* Selected
1.1.1.31.x.6.y.48 Power supply unit fuse fault
* Selected
1.1.1.31.x.6.y.49 Power supply unit battery
fault
* Selected
1.1.1.31.x.6.y.50 Radio output battery fault
* Selected
1.1.1.31.x.6.y.51 Siren battery fault
* Selected
1.1.1.31.x.6.y.52 No power supply unit
network
* Selected
1.1.1.31.x.6.y.53 Radio zone battery fault
* Selected
1.1.1.31.x.6.y.54 Radio control battery fault
* Selected
1.1.1.31.x.6.y.55 Input voltage level fault
* Selected
1.1.1.31.x.6.y.56 Output voltage level fault
* Selected
1.1.1.31.x.6.y.57 Zones RX monitoring
* Selected
1.1.1.31.x.6.y.58 Outputs RX monitoring
* Selected
1.1.1.31.x.6.y.59 Output fault
* Selected
1.1.1.31.x.6.y.60 Camera fault
* Selected
1.1.1.31.x.6.y.61 No GSM/GPRS coverage
* Selected
1.1.1.31.x.6.y.62 Telephone line fault
* Selected
1.1.1.31.x.6.y.63 Failed communication fault
* Selected
1.1.1.31.x.6.y.64 Robbery zone fault
* Selected
1.1.1.31.x.6.y.65 Failed activation fault
* Selected
1.1.1.31.x.6.y.66 IP Expansion fault on bus
* Selected
1.1.1.31.x.6.y.67 Motion sensor jamming
fault
* Selected
1.1.1.31.x.6.y.70 I/O expansion Bus Fault
* Selected
1.1.1.31.x.6.y.71 Keypad Bus Fault
* Selected
1.1.1.31.x.6.y.72 Reader Bus Fault
* Selected
1.1.1.31.x.6.y.73 Safe Touch Bus Fault
* Selected
1.1.1.31.x.6.y.74 Touch Bus Fault
* Selected
1.1.1.31.x.6.y.75 Isolator Power Supply Unit
Bus Fault
* Selected
1.1.1.31.x.6.y.76 Radio Concentrator Bus
Fault
* Selected
1.1.1.31.x.6.y.77 Siren Bus Fault
* Selected
1.1.1.31.x.6.y.78 Alarm Communication
Device Bus Fault
* Selected
1.1.1.31.x.6.y.79 IP Expansion Bus Fault
* Selected
1.1.1.31.x.6.y.80 IP Video Expansion Bus
Fault
* Selected
1.1.1.31.x.6.y.86 Control Panel Battery Fault
* Selected
1.1.1.31.x.6.y.87 Control Panel Power Supply
Mains Outage
* Selected
1.1.1.31.x.6.y.88 Control panel pstn fault
* Selected
1.1.1.31.x.6.y.89 Control panel GSM fault
* Selected
1.1.1.31.x.6.y.90 Control panel IP fault
* Selected
1.1.1.31.x.6.y.91 Control panel voice
synthesis fault
* Selected
1.1.1.31.x.6.y.94 Auxiliary power supply
fuse fault
* Selected
1.1.1.31.x.6.y.95 Bus power supply fuse fault
* Selected
1.1.1.31.x.6.y.96 Siren power supply fuse
fault
* Selected
1.1.1.31.x.6.y.97 Control panel power supply
unit fault
* Selected
1.1.1.31.x.6.y.98 Control panel bus fault
* Selected
1.1.1.31.x.6.y.99 Telephone line fault
* Selected
1.1.1.31.x.6.y.100
No GSM network
* Selected
1.1.1.31.x.6.y.101
No GPRS network
* Selected
1.1.1.31.x.6.y.102
Date lost
* Selected
1.1.1.31.x.6.y.108
L2 forced ON
* Selected
1.1.1.31.x.6.y.109
L3 forced ON
* Selected
1.1.1.31.x.6.y.116
Timed activation error
* Selected
1.1.1.31.x.6.y.119
Technical programming
* Selected
1.1.1.31.x.6.y.120
Control panel in service
* Selected
1.1.1.31.x.6.y.126
Change date and time
* Selected
1.1.1.31.x.6.y.127
Change site data
* Selected
1.1.1.31.x.6.y.140
Lock RFID
* Selected
1.1.1.31.x.6.y.143
Lock Web
* Selected
1.1.1.31.x.6.y.144
Lock PC
* Selected
1.1.1.31.x.6.y.145
Lock SMS
* Selected
1.1.1.31.x.6.y.146
Voice Lock
* Selected
1.1.1.31.x.6.y.151
Activation action
* Only set selected
1.1.1.31.x.6.y.152
Burglar Alarm Action
* Only set selected
1.1.1.31.x.6.y.153
24H Alarm Action
* Only set selected
1.1.1.31.x.6.y.154
Fire Alarm Action
* Only set selected
1.1.1.31.x.6.y.155
Panic Alarm Action
* Only set selected
1.1.1.31.x.6.y.156
Robbery Alarm Action
* Only set selected
1.1.1.31.x.6.y.157
Flood Alarm Action
* Only set selected
1.1.1.31.x.6.y.158
Gas Alarm Action
* Only set selected
1.1.1.31.x.6.y.159
Medical Alarm Action
* Only set selected
1.1.1.31.x.6.y.177
Zone exclusion command
* Only set selected
1.1.1.31.x.6.y.178
Zone inclusion command
* Only set selected
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.31.x.6.y.179
Zone isolation command
* Only set selected
1.1.1.31.x.6.y.180
Zone activation command
* Only set selected
1.1.1.31.x.6.y.183
Safe Touch lock
* Selected
1.1.1.31.x.6.y.188
Touch lock
* Selected
1.1.1.31.x.6.y.200
App lock
* Selected
1.1.1.31.x.6.y.205
Touch lock
* Selected
1.1.1.31.x.6.y.208
Digital dialler manual test
* Selected
* Only for the digital dialler columns
5.5.21 Service voice messages
x: from 1 to 6
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.36.x.1
Text
The system address field must be
completed
5.5.22 System Parameters
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.42.1.1
DB version
Cannot be edited
1.1.1.42.1.2
Customer Name
Fill in the field
1.1.1.42.1.3
System Address
Fill in the field
1.1.1.42.1.4
Network alarm delay
Max 60 seconds
1.1.1.42.1.5
Battery alarm delay
Max 5 minutes
1.1.1.42.1.14
Code errors
10
1.1.1.42.1.15
Reactivation time
Minimum 2 minutes
1.1.1.42.1.16
Alarm Cycles
Unlimited
1.1.1.42.1.17
Fault Cycles
Unlimited
1.1.1.42.1.18
Unlimited Alarm Cycles
Selected
1.1.1.42.1.19
Unlimited fault cycles
Selected
1.1.1.42.1.20
Device locked for incorrect
code
Selected
1.1.1.42.1.23
Activation with monitoring
fault
Selected
1.1.1.42.1.24
Forcing level 3 faults
Selected
1.1.1.42.1.25
Forcing level 3 sabotage
Selected
1.1.1.42.1.30
Installer always active
Deselected
1.1.1.42.1.33
Audio control enable
Active if digital dialler is not enabled
1.1.1.42.1.34
GSM card enable
At least one active between PSTN
and GSM
1.1.1.42.1.37
PSTN enable (on board)
At least one active between PSTN
and GSM
1.1.1.42.1.38
Failed activation fault
enable
Selected
1.1.1.42.1.39
Enable test for fault and
zones sabotage
Deselected
5.5.23 Events to be saved
x: from 1 to 2
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.43.x.2
Zone Exclusion
Selected
1.1.1.43.x.3
Zone Isolation
Selected
1.1.1.43.x.4
Total ON
Only set selected
1.1.1.43.x.5
Partial 1 ON
Only set selected
1.1.1.43.x.6
Partial 2 ON
Only set selected
1.1.1.43.x.7
Effective activation
Only set selected
1.1.1.43.x.8
Deactivated
Only set selected
1.1.1.43.x.10
Burglar Alarm
Selected
1.1.1.43.x.11
24H Alarm
Selected
1.1.1.43.x.12
Fire Alarm
Selected
1.1.1.43.x.13
Panic Alarm
Selected
1.1.1.43.x.14
Robbery Alarm
Selected
1.1.1.43.x.15
Flood alarm
Selected
1.1.1.43.x.16
Gas Alarm
Selected
1.1.1.43.x.17
Medical Alarm
Selected
1.1.1.43.x.18
Zones Sabotage Tamper
Selected
1.1.1.43.x.19
Siren tamper
Selected
1.1.1.43.x.20
Radio device jamming
Selected
1.1.1.43.x.21
Tamper App
Selected
1.1.1.43.x.26
Bus I/O expansions tamper Selected
1.1.1.43.x.27
Bus keypad tamper
Selected
1.1.1.43.x.28
RFID tamper
Selected
1.1.1.43.x.29
Safetouch tamper
Selected
1.1.1.43.x.30
Touch Tamper
Selected
1.1.1.43.x.31
Bus power supply station or
isolator tamper
Selected
1.1.1.43.x.32
Bus radio concentrator
tamper
Selected
1.1.1.43.x.33
Bus siren tamper
Selected
1.1.1.43.x.34
Alarm communication
device tamper
Selected
1.1.1.43.x.35
IP expansion tamper
Selected
1.1.1.43.x.36
IP video expansion tamper
Selected
1.1.1.43.x.42
Remote communications
tamper
Selected
1.1.1.43.x.43
GSM concentrator jamming Selected