3.4.4 TCP/IP Ethernet expansion module (Art. VE-
DOIP)
Provides support for connecting the alarm control panel to the
network. Allows an authorised user to access the control panel
locally or remotely. Once connected to the control panel, users
can totally or partially activate and deactivate the areas within
their sphere of competence, and check the status of each input.
Equipped with a plug-in connector for simplified fitting. Needs
to be connected to a LAN with Standard Ethernet 10BASE-T
IPv4
TECHNICAL SPECIFICATIONS
Features Value
Name of manufacturer / supplier
Comelit Group S.p.A.
Dimensions (b x h x d)
75 x 31 x 33 mm
Weight
18 g
Consumption (min./max.)
69mA
Operating temperature and Operating
humidity
-10° / + 55° with warm dry air
-10° / + 40° C with max + 93% RH
(not condensed)
Certifiable safety grade
2 according to EN50131-1*
Environmental class
II according to EN50131-1
Features Value
Generation and/or transmission
times of alarm messages
e-mail:
4 sec without image / 35 sec
with image
Times for detecting and presenting
faults
No link:
10 sec.
No internet:
120 sec.
SD fault:
10 sec.
DDNS interrogation fault:
35 sec.
Calibration instructions
Calibration not necessary
Sharing of transmission connections
Standard Ethernet 10BASE-T IPv4
Art. VEDOIP complies with standards EN50131-1 and
EN50131-3
TCP/IP MODULE FUNCTIONS
• Ethernet Interface.
• Event transmission on IP
• Programming and Monitoring of the control panel via LAN
through Safe Manager
• Programming and Monitoring of the control panel via
Internet through Safe Manager
• Control panel management vie Internet through Vedo App
• Event alert via e-mail and on Vedo App with alerts with
proprietary protocol
• Alert by e-mail for alarms/malfunctions/sabotage/events
with images
1.
RJ45 connector yellow LED
2.
RJ45 connector green LED
3.
RJ45 network connector
4.
Micro SD memory slot
Holes for fixing the VEDOIP module to the control panel card Art.
PCBVEDO10, Art. PCBVEDO34, Art. PCBVEDO68
* Respecting any indications for configuration and installation
SPECIFICATIONS ACCORDING TO STANDARD EN50136-2-1
Make sure the card on which you intend to fit the
module is not connected to the power supply.
Insert the plastic spacers in the relevant holes. Press the
spacers until they click into the TP/IP expansion card.
MEANING OF THE LEDS ON THE IP MODULE
Meaning of the LEDs of the RJ45 network connector
Meaning of the LEDs on the IP module (Normal operating mode)
Meaning of the LEDs on the IP module (Program updating stage)
FITTING THE TCP/IP MODULE
Name Function
Yellow LED ON
link OK
Green LED ON
ACT
Name Status
Function
D1
flashing slowly
module working correctly
flashing quickly
module operating but SD memory card missing
or defective
D2 flashing
confirms communication with the control panel
Name Status
Function
D1+D2
D1+D2 steadily lit
Updating in progress
D1 fl D2
inverted flashing
MicroSD card missing
D1 steadily lit + D2
flashing
MicroSD card missing for a file necessary
for correct operation
The IP communication module is equipped with a
compartment for a 4GB MicroSD memory card.
FITTING THE MICROSD MEMORY CARD
FITTING THE RJ45 CONNECTOR
FITTING THE RJ45 CONNECTOR
REMOVING THE MICROSD MEMORY CARD
Fully insert the card into the connector with the gold-
coloured contacts not visible.
1.
Push the card fully into the connector, then
2.
release it: the card will be pushed outwards so that you can
grip it more easily.
In order to be used, once fitted on the control panel
card, the IP module must be connected to a Standard
Ethernet 10BASE-T compatible hub or to a switch with
the same specifications, that allows it to be connected to
a data network. For further details on this operation see
paragraph "5.8 Data network connection cable" on page
58
Plug the cable in fully, until you feel it engage, in the only
accessible connector of the IP communication module, with
the tab facing the front panel of the control panel housing.
Press the tab (1) of the connector and remove it from the
module (2).