11
C
B
A
2
4
6
3
1
5
A1
A2
A3
1
2
3
A
B
C
8
9
11 10
7
2.4 ROUTES FOR
SEPARATING THE
SELV CIRCUIT
AND THE HIGH
VOLTAGE CIRCUIT
(FOR ART.
BOXMETAL)
For standard-compliant
installation, pay attention
to the correct route of the
earthing cables and of the
SELV circuit and high voltage
cables.
(!) With the VEDOCCTV
module fitted in a central
position (as in the picture) use
a mains power supply cable
with double insulation (to
prevent the coaxial cables of
the cameras coming in contact
with 230V wires)
(!) If the mains cable inlet hole
is shared with other cables of
the control panel wiring (as
in the picture), use a mains
power supply cable with
double insulation.
1.
GSM antenna output
2.
Expansion antenna connector Art.
VEDOGSM
3.
PSU connector
4.
Battery connector
5.
VEDOIP expansion network connector
6.
Balance resistor
7.
Tamper connectors
8.
VEDOCCTV network connector
9.
Earth connection according to
standard EN60950.
#
10.
Internal fuse 250V~ T2A (for Art.
PSU15), Internal fuse 250V~ T2.5A
(for PSU50)
11.
High Voltage Cables.
A1.
Position of communication module
VEDOGSM
A2.
Position of messages expansion
VEDOVOICE
A3.
Position of IP module VEDOIP
#