![Comelit VEDO10 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/comelit/vedo10/vedo10_technical-manual_2640394027.webp)
27
1
2
3
4
5
6
7
8
9
10
11
12
13
MB
MA
B
A
V–
S–
RJ45
S+
JP2
AL
CFP
DL2
DL1
PAN
D
V+
V–
JP1
MOUNTING
The article Icona Manager ViP (Art. 20003310W) can be
installed:
• with flush-mounted box Art. 6117 (see page 46)
• with wall support Art. 6620 (see page 45)
Icona Manager ViP is a built-in supervisor with door entry
monitor functions and the ability to display and check the status
of the SimpleHome home automation system and of the Vedo
anti-intrusion system.
• LCD display 4.3’’ 16:9 capacitive touch
• RJ45 connector for connection to the Ethernet network
• RFID antenna for reading Comelit keys
• Sensor for detecting ambient temperature and humidity
0-45°C, pre/- 0.3 °C
• Real time clock (RTC);
• Micro SD connector accessible;
• Micro SD for saving data, loading custom ringtones, saving
and exporting films from the video memory;
• Audio broadcast
MAIN FEATURES:
TECHNICAL SPECIFICATIONS
Features
Value
Name of manufacturer / supplier
Comelit Group S.p.A.
Dimensions (b x h x d)
147 x 142 x 23 mm
Weight
282g
Consumption (min./max.)
75mA medium,
160mA TFT on,
200mA max.
Operating voltage
10V at 24V
Operating temperature
-5° / +45° C
Operating humidity
0-90% RH
Device Type
A according to EN50131-3
Environmental class
I according to EN50131-1
1.
Microphone
2.
4.3" touch screen, 16:9
3.
RFID key sensor
4.
Door opening button (programmable)
5.
Privacy / Doctor key [programmable]
6.
Self-ignition key [programmable]
7.
Open doors key
8.
Video memory key
9.
Key "3" [programmable]
default = off
10.
Key "2" [programmable]
default = general actuator
11.
Key "1" [programmable]
default = off
12.
Audio key
13.
Micro SD card input
Name Function
MB
negative of the secondary RS485 bus
(terminal not fitted by product rev1.0)
MA
positive of the secondary RS485 bus
(terminal not fitted by product rev1.0)
B
negative of the alarm RS485 bus
A
positive of the alarm RS485 bus
V-
card earth
S-
negative pole of the additional ringtone output
S+
positive pole of the additional ringtone output
Name Function
D
home automation bus
V-
card earth
V+
power supply positive pole
Name Function
AL
alarm contact input
PAN
panic contact input
CFP
contact input outside door
DESCRIPTION OF TERMINAL BLOCK 1
DESCRIPTION OF TERMINAL BLOCK 2
DESCRIPTION OF TERMINAL BLOCK 3
See Mini Touch page 25.
See Mini Touch page 25.
ADDRESSING THE DEVICE ON THE BUS
SPEED SETTING
3.8.3 Icona Manager ViP (Art. 20003310W)
Name
Function
JP1
if closed, enables the 120 Ohm termination between lines A and B
of RS485 alarm bus
JP2
if closed, enables the 120 Ohm termination between lines MA and
MB of the secondary RS485 bus
(jumper not fitted by product rev1.0)
Name
Status
Function
DL1
Flashing
signals Ethernet activity
DL2
Yellow
data transmission and reception activity on the
SimpleHome bus
Red
data collision on the SimpleHome bus
485 LINE TERMINATION
LED MEANINGS