V+
V-
D
A
B
NC
COM
NO
I1
I2
I3
1.
Access the settings menu by pressing
.
2.
Type in the installer code (default=1961) and confirm
3.
Follow this path "Options/Configuration/Bus 485 address"
4.
Type in the identification number of the device on the bus
and confirm (to modify the address, delete the present value
by pressing ‘
C
’).
Name
Function
V+
Power supply positive input *
V-
Power supply negative input, common to home automation bus
D
Data Signal for home automation Simplebus
A
RS485 data bus - A
B
RS485 data bus - B
NC
Output 1 relay normally closed contact (for Mini Touch only for home
automation use)
COM
Output 1 common relay (for Mini Touch only for home automation use)
NO
Output 1 relay normally open contact (for Mini Touch only for home
automation use)
I1
Programmable input/output connection (for Mini Touch only for home
automation use)
I2
Programmable input/output connection (for Mini Touch only for home
automation use)
I3
Programmable input/output connection (for Mini Touch only for home
automation use)
Name
Function
CV8
If activated, connects the line termination to the 485 bus line
Colour
Signal
steady red
Alarm memory
flashing red
Alarm in progress
yellow
Alarm system fault
blue
Climate on in summer mode.
orange
Climate on in winter mode.
The device has a LED backlit system that indicates the status
of the system climate zones and the status of the anti-intrusion
system.
The LED indicates one event at a time, giving priority to alarm
events. In the absence of signals a courtesy light is active (if
programmed), with a colour defined at the time of configuration.
DESCRIPTION OF TERMINAL BLOCK
485 LINE TERMINATION
LED MEANINGS
ADDRESSING THE DEVICE ON THE BUS
Like any other device connected to the 485 bus, the
Vedo
Touch/Mini Touch
must respond to a single address that can
be configured from the display.
*The device Mini Touch Art. 20034607 must be powered by the
control panel or by Comelit Art. 20022101 or another security
power supply unit in compliance with EN 61558-2-6.
The RS485 bus of the device must be connected exclusively
to other Comelit devices (alarm bus).
The Ethernet ports can be connected to other Comelit
devices or to other 10Base2 Ethernet ports where there is
no potential overvoltage on the distribution system (wiring
contained within a single building).
TECHNICAL SPECIFICATIONS
Features
Value
Name of manufacturer / supplier
Comelit Group S.p.A.
Dimensions (b x h x d)
125 x 85 x 28 mm
Weight
150g
Consumption (min./max.)
80mA all off
135mA TFT on
250mA led on at 100%
Operating voltage
10V at 24V
Operating temperature
-15° / +55°C
Operating humidity
max +85% RH (not condensed)
Device Type
B (Vedo Touch) / A (Mini Touch)
according to EN50131-3
Environmental class
II according to EN50131-1
For Vedo Touch
1.
Access the alarm menu with
and press the icon
.
2.
Type in the installer code (default=1961) and confirm
3.
Follow this path "Options/Configuration/Bus 485 address"
4.
Type in the identification number of the device on the bus
For Mini Touch
1.
Access the settings menu by pressing
.
2.
Type in the installer code (default=1961) and confirm
3.
Follow this path "Options/Configuration/Bus 485 speed"
4.
Select the desired speed (default=38400)
SPEED SETTING
MOUNTING
The article Vedo Touch (Art. VEDOTOUCH) / Mini Touch (Art.
20034607) can be installed on box 503 (see page 42)
For Vedo Touch
1.
Access the alarm menu with
and press the icon
.
2.
Type in the installer code (default=1961) and confirm
3.
Follow this path "Options/Configuration/Bus 485 speed"
4.
Type in the identification number of the device on the bus
For Mini Touch