WIRED OUTPUT CONFIGURATION

Indices

Parameters

Configurations necessary to 

guarantee Grade 2 certification

1.1.1.17.x.12.1.1

Timer in And

* No timer

1.1.1.17.x.12.1.2

Timer in Or

* No timer

1.1.1.17.x.12.1.7

Events logic

* OR

1.1.1.17.x.12.1.10

Send digital dialler

Selected

1.1.1.17.x.12.1.12

Output activation only with 

system activated

Selected if connected to a siren

* These apply only to outputs connected to sirens. 

For standard EN50131 an output of the control panel must be activated in the case of a fault and 

must not be connected to a siren.

5.5.13 User

Vedo 10

 x: from 1 to 8 / 

Vedo 34

 x: from 1 to 32 / 

Vedo 68

 x: from 1 to 50

Indices

Parameters

Configurations necessary to 

guarantee Grade 2 certification

1.1.1.20.x.18

Send digital dialler

Selected

The codes accepted must have 6 figures and range from 000000 to 999998. Code 999999 is 

not an accepted code. The robbery code is the user code + 1.

Example: user code 111111, the corresponding robbery code is 111112. Code 119999, 

robbery code = 120000. Code 123459, robbery code = 123460 - It is not possible to register 

a user code corresponding to an existing user code + 1, since this new code corresponds to 

the robbery code of the existing user.

In the system it is therefore possible to store up to a theoretical maximum of 999943 user 

codes. The calculation is the result of the fact that it is not possible to create a user code that 

is the same as an existing user code + (which is the robbery code). The actual maximum 

number of user codes that can be fitted is shown in the table "USER CODES / KEYS / 

REMOTE CONTROLS" on  page 5.

The authorised user can perform an infinite number of changes of his user code and can 

create and eliminate another user, whereas he is unable to modify any user code other than 

his own.

CODE TYPE

x: from 1 to 9

Indices

Parameters

Configurations necessary to 

guarantee Grade 2 certification

1.1.1.22.x.19

Request assistance

Active for at least one type of user (x 

enab. inst.) and one type of installer (x 

enab. manuf.)

1.1.1.22.x.20

Change Pin

Active only for installers

1.1.1.22.x.21

Reset control panel

Active for manufacturer

1.1.1.22.x.23

Fault management

Active

1.1.1.22.x.26

Programme from PC

Active for installer and manufacturer

1.1.1.22.x.42

Codes menu

Active

1.1.1.22.x.44

FW Update

Only for manufacturer

5.5.14 Installers

Vedo 10

 x: from 1 to 3 / 

Vedo 34

 x: from 1 to 6 / 

Vedo 68

 x: from 1 to 6

Indices

Parameters

Configurations necessary to 

guarantee Grade 2 certification

1.1.1.21.x.6

Send digital dialler

Selected

CODE TYPE

x: from 1 to 9

Indices

Parameters

Configurations necessary to 

guarantee Grade 2 certification

1.1.1.22.x.19

Request assistance

Active for at least one type of user (x 

enab. inst.) and one type of installer (x 

enab. manuf.)

1.1.1.22.x.20

Change Pin

Active only for installers

1.1.1.22.x.21

Reset control panel

Active for manufacturer

1.1.1.22.x.23

Fault management

Active

1.1.1.22.x.26

Programme from PC

Active for installer and manufacturer

1.1.1.22.x.42

Codes menu

Active

1.1.1.22.x.44

FW Update

Only for manufacturer

5.5.15 GSM settings

Indices

Parameters

Configurations necessary to 

guarantee Grade 2 certification

1.1.1.25.1.24

Jamming control

Selected

5.5.16 Telephone Options

Indices

Parameters

Configurations necessary to 

guarantee Grade 2 certification

1.1.1.27.1.5

Tones recognition timeout

= 60 seconds

1.1.1.27.1.9

Telephone line parameters 

(pstn)

Selected

1.1.1.27.1.10

Length of call

= 60 seconds

1.1.1.27.1.12

Voice message repetition

5

1.1.1.27.1.14

Attempts

3

1.1.1.27.1.15

Send message

Press key 1

1.1.1.27.1.16

Termination with 

confirmation

Selected

1.1.1.27.1.19

Tones control (pstn)

Selected

1.1.1.27.1.20

Telephone line control 

(pstn)

Selected

5.5.17 Phone Book / Email

x: from 1 to 16

Indices

Parameters

Configurations necessary to 

guarantee Grade 2 certification

1.1.1.28.x.1

Description

*

1.1.1.28.x.2

Phone

*

* If the digital dialler is not active, at least one user must be present

5.5.18 Digital dialler contacts list

x: from 1 to 4

Indices

Parameters

Configurations necessary to 

guarantee Grade 2 certification

1.1.1.29.x.2

Periodic test

Active

1.1.1.29.x.4

Protocol

Contact ID

1.1.1.29.x.5

Test period

<=25h

1.1.1.29.x.6

Attempts

1

1.1.1.29.x.7

Number to call

If the digital dialler is not active, at 

least the telephone sounder must be 

correctly configured

1.1.1.29.x.8

Customer code

Valorised

1.1.1.29.x.10

Periodic test start date

Value before date of activating the 

system (must be before current date)

5.5.19 Generic events

Vedo 10

 x: from 1 to 20 / 

Vedo 34

 x: from 1 to 32 / 

Vedo 68

 x: from 1 to 48

Indices

Parameters

Configurations necessary to 

guarantee Grade 2 certification

1.1.1.30.x.2

Event

*

1.1.1.30.x.5

Activation voice message

Active for at least one phone

1.1.1.30.x.6

Reset voice message

Active for at least one phone

* If the digital dialler is not active, the following events must be signalled: 

- Robbery Alarm 

- Burglar Alarm 

- H24 Alarm 

- Sabotage 

- No network 

- Radio sensor battery low 

- Radio siren battery low 

- Auto-activation failed 

- Failed activation fault 

- Zone fault 

- Robbery zone fault 

- Motion sensor jamming fault 

Of course it must also be completed by sending the respective voice message.

5.5.20 Detailed events

x: from 1 to 8  

y: from 1 to 6

Indices

Parameters

Configurations necessary to 

guarantee Grade 2 certification

1.1.1.31.x.3

Dialler telephones

At least one selected

1.1.1.31.x.4

Areas

At least one selected

DETAILED EVENTS FLAGS

Indices

Parameters

Configurations necessary to 

guarantee Grade 2 certification

1.1.1.31.x.6.y.2

Zone Exclusion

* Selected

1.1.1.31.x.6.y.3

Zone Isolation

* Selected

1.1.1.31.x.6.y.4

Total ON

* Only set selected

1.1.1.31.x.6.y.5

Partial 1 ON

* Only set selected

1.1.1.31.x.6.y.6

Partial 2 ON

* Only set selected

1.1.1.31.x.6.y.7

Effective activation

* Only set selected

1.1.1.31.x.6.y.8

Deactivated

* Only set selected

1.1.1.31.x.6.y.10 Burglar Alarm

* Selected

1.1.1.31.x.6.y.11 24H Alarm

* Selected

1.1.1.31.x.6.y.12 Fire Alarm

* Selected

1.1.1.31.x.6.y.13 Panic Alarm

* Selected

1.1.1.31.x.6.y.14 Robbery Alarm

* Selected

1.1.1.31.x.6.y.15 Flood alarm

* Selected

1.1.1.31.x.6.y.16 Gas Alarm

* Selected

1.1.1.31.x.6.y.17 Medical Alarm

* Selected

1.1.1.31.x.6.y.18 Zones Sabotage Tamper

* Selected

1.1.1.31.x.6.y.19 Siren tamper

* Selected

1.1.1.31.x.6.y.20 Radio device jamming

* Selected

1.1.1.31.x.6.y.21 Tamper App

* Selected

1.1.1.31.x.6.y.26 Bus I/O expansions tamper

* Selected

1.1.1.31.x.6.y.27 Bus keypad tamper

* Selected

1.1.1.31.x.6.y.28 RFID tamper

* Selected

1.1.1.31.x.6.y.29 Safetouch tamper

* Selected

1.1.1.31.x.6.y.30 Touch Tamper

* Selected

1.1.1.31.x.6.y.31 Bus power supply station or 

isolator tamper

* Selected

1.1.1.31.x.6.y.32 Bus radio concentrator 

tamper

* Selected

1.1.1.31.x.6.y.33 Bus siren tamper

* Selected

1.1.1.31.x.6.y.34 Alarm communication 

device tamper

* Selected

1.1.1.31.x.6.y.35 IP expansion tamper

* Selected

Содержание VEDO10

Страница 1: ...Passion Technology Design EN TECHNICAL MANUAL Technical manual for the Vedo system...

Страница 2: ...mally closed NC 19 3 6 2 Normally open NO 19 3 6 3 Single balance 19 3 6 4 Double balance 19 3 6 5 Triple balance 20 3 6 6 Triple balance with jamming 20 3 6 7 Double zone double 20 3 6 8 Double zone...

Страница 3: ...NFIGURATION JUMPERS 31 CONNECTING VEDOCCTV WITH SWITCH HUB AND CONTROL PANEL POWER SUPPLY 31 CONNECTING THE VEDOCCTV MODULE WITH POE SWITCH HUB 31 MMS SUPPORT SYSTEM DESCRIPTION AND MINIMUM REQUIREMEN...

Страница 4: ...er code authorisation 49 5 3 13 Changing date and time 49 5 3 14 Acquiring an RFID key code from the keypad 49 5 3 15 Acquiring a radio sensor code from the keypad 50 5 3 16 Acquiring a radio control...

Страница 5: ...ontrol panel can be programmed directly from the keypad or more easily by means of dedicated software The audio messages can be modified only by using the programming software from a PC The associatio...

Страница 6: ...e CONTACT ID protocol Yes Priority in processing and indicating signals 1 Alarm Events 2 Sabotage 3 Malfunctions 4 Exclusions 5 Other events In the telephone options it is possible to set the priority...

Страница 7: ...he control panel Depends on the control panel configuration With battery Art 30076004 12V and 18Ah Grade 2 1500mA mean current absorbed by the control panel Depends on the control panel configuration...

Страница 8: ...erating temperature and Operating humidity 10 55 with warm dry air 10 40 C with max 93 RH not condensed Safety grade 2 according to EN50131 1 Environmental class II according to EN50131 1 1 2 3 Power...

Страница 9: ...or power supply unit PSU15 7 Internal fuse 250V T2A for Art PSU15 Internal fuse 250V T2 5A for PSU50 8 Cable for connecting the power supply unit to earth Art PSU15 9 High Voltage Cables 10 Cable for...

Страница 10: ...rew for power supply unit Art PSU15 Optional positions a Holes for fitting supports for fixing the expansion Art VEDO8I8O b Screws for fixing and holding PAL module Art VEDOCCTV for further informatio...

Страница 11: ...ing in contact with 230V wires If the mains cable inlet hole is shared with other cables of the control panel wiring as in the picture use a mains power supply cable with double insulation 1 GSM anten...

Страница 12: ...ge 39 Art BOXPLASTIC complies with standards EN50131 1 EN50131 3 EN50131 6 EN50136 1 1 EN50136 2 1 EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 EN50130 4 Art BOXMETAL complies with standards EN50...

Страница 13: ...3 8 V self resettable fuse for protecting the power supply to the siren outputs 1 5A 13 8 V self resettable fuse for protecting the power supply to the RS485 buses 1 5A 13 8 V self resettable fuse for...

Страница 14: ...r supply negative I7 Programmable input zone 7 I8 Programmable input zone 8 V AUX Power supply positive for signal sensors Electrically connected to terminal 1 of the same terminal block Shares its li...

Страница 15: ...od ule Art VEDOVOICE Optional contains the part of the audio messages relating to the digital dialler i e contains the audio messages to be sent on the standard or GSM telephone line Equipped with a p...

Страница 16: ...ACCORDING TO STANDARD EN50136 2 1 FITTING THE GSM MODULE Insert the plastic spacers in the relevant holes Then taking care to plug the module connector into the control panel connector designated MOD...

Страница 17: ...an external antenna Art 2G50000296 For this purpose there is a pre marked section to allow easy exit of the antenna cable OK NO FITTING THE SIM CARD The SIM card must be enabled and if it is a pay as...

Страница 18: ...o the control panel card Art PCBVEDO10 Art PCBVEDO34 Art PCBVEDO68 Respecting any indications for configuration and installation SPECIFICATIONS ACCORDING TO STANDARD EN50136 2 1 Make sure the card on...

Страница 19: ...cond balancing resistor also 1 8K makes it possible to distinguish an alarm state from a line sabotage state both in the event of cutting and short circuit IMPORTANT input balancing resistors if used...

Страница 20: ...d balancing resistor 3 3K disposed in parallel to the contact of the second sensor to be monitored This configuration makes it possible to distinguish between an alarm electrical fault state and a lin...

Страница 21: ...DOLCD and keypad with RFID key reader Art VEDOLCDPROX MAIN FEATURES The LCD keypad allows an authorised user to enable and disable the system to check the system status and manage its general features...

Страница 22: ...red speed 3 Once you have set the speed set DIP switch 6 back to OFF The speed is now set 4 Set DIP switches 1 to 5 according to the address to be set Note that the standard speed of the bus for VEDO...

Страница 23: ...RS485 data bus B MEANING OF THE LEDS WHEN THE CYCLE IS IN PROGRESS LED Status Function Red On Request execution of action associated with LED Slow flash Action associated with LED requires forcing to...

Страница 24: ...of the bytes that form the unique code of the key and can have a value between 1 and 2 32 1 therefore generating a maximum number of 2 32 2 possible values Vedo Touch Minitouch is an innovative inter...

Страница 25: ...HE BUS Like any other device connected to the 485 bus the Vedo Touch Mini Touch must respond to a single address that can be configured from the display The device Mini Touch Art 20034607 must be powe...

Страница 26: ...according to EN50131 1 1 CV8 485 line termination 2 Terminal block for system connection 3 CV5 Jumper for video closure 4 CN4 CN5 Monitor bracket connectors 1 Microphone 2 Touch screen 3 Key sensor 4...

Страница 27: ...button programmable 5 Privacy Doctor key programmable 6 Self ignition key programmable 7 Open doors key 8 Video memory key 9 Key 3 programmable default off 10 Key 2 programmable default general actua...

Страница 28: ...ing with 2 self tapping screws The cover is secured to the base by means of three fasteners on the top and two spring clips at the bottom There are also two safety screws to prevent accidental opening...

Страница 29: ...and or volumetric detectors and supervised wireless sirens to the control panel 1 Dip Switch 2 Anti tear tamper 3 Anti tamper tamper Holes for fixing the VEDORF card to the metal housing Art BOXMETAL...

Страница 30: ...lting the recorded films of the cameras on the system 4 IP cameras and one chosen analogue camera by the system manager Vedo Touch Mini Touch Icona Manager VIP or by App 1 Reserved terminals 2 Etherne...

Страница 31: ...o operate in case of temporary absence of mains power The power supply from the control panel allows the device to operate in case of temporary absence of mains power IMPORTANT In order to use the vid...

Страница 32: ...SIREN V COM V V TC1 TC2 V SIR NO NC COM M2 SELF POWERED SIREN V COM V V TC TC V S NO NC CO M 3 WIRE CONNECTION 2 WIRE CONNECTION SELF POWERED SIREN V COM V V TC1 TC2 V SIR NO NC COM M2 SELF POWERED S...

Страница 33: ...d as TC If the output is configured as a TC in standby the output will be fluctuating no voltage but in active status it will close terminal TC to positive This type of behaviour can be figured with t...

Страница 34: ...ed to 1 5A V Power supply negative output reference 485 communication BUS power supply A RS485 data BUS for connection to other devices OUT A B RS485 data BUS for connection to other devices OUT B bus...

Страница 35: ...ect the entire system The device is equipped with a dual connection to the VEDO system 485 BUS the IN port input the OUT port output The section of the system that you want to isolate from the rest mu...

Страница 36: ...package on the BUS To access dip switch S1 and jumpers JP1 and JP2 you must remove the plastic casing at the top DEFAULT The 24H terminal needs the Tamper contact to be connected in single balanced co...

Страница 37: ...HOUSING ART BOXPLASTIC 4 3 FIXING THE HOUSING ART BOXPLASTIC TO THE WALL 4 2 PREPARING THE HOUSING ART BOXPLASTIC If the control panel is already assembled you will have to remove the electronic cards...

Страница 38: ...CONTROL PANEL CARD ART PCBVEDO10 PCBVEDO34 PCBVEDO68 AND PCBPSU IN A HOUSING ART BOXPLASTIC 4 5 MOUNTING THE POWER SUPPLY UNIT PSU15 IN A HOUSING ART BOXPLASTIC 4 6 MOUNTING THE EXPANSION ART VEDO8I8...

Страница 39: ...ART BOXMETAL 4 8 FIXING THE HOUSING ART BOXMETAL TO THE WALL 2 1 1 4 9 MOUNTING THE CONTROL PANEL CARD ART PCBVEDO10 PCBVEDO34 PCBVEDO68 AND PCBPSU IN A HOUSING ART BOXMETAL 4 10 MOUNTING THE EXPANSI...

Страница 40: ...40 2 1 1 2 3 4 CLACK 1 2 2 1 3 BLOCKING OPTIONAL 4 11 MOUNTING THE POWER SUPPLY UNIT PSU15 PSU50 IN A HOUSING ART BOXMETAL 4 12 MOUNTING THE MODULE ART VEDOCCTV IN A METAL HOUSING ART BOXMETAL...

Страница 41: ...41 2 2 3 2 1 2 1 1 1 4 4 2 1 2 1 3 3 1 3 2 2 1 3 2 2 4 13 MOUNTING THE KEYPAD ART VEDOLCD ART VEDOLCDPROX ON BOX 503 4 14 MOUNTING THE KEYPAD ON THE WALL ART VEDOLCD ART VEDOLCDPROX OPENING OPENING...

Страница 42: ...42 3 150 cm 120 cm 2 1 4 4 15 MOUNTING THE VEDO TOUCH ART VEDOTOUCH MINI TOUCH ART 20034607 ON BOX 503 OPENING...

Страница 43: ...43 2 3 4 5 1 3 145 150 cm 115 125 cm 2 14 5 cm 14 5 cm 1 6 5 ALTO UP HAUT OBEN 4 9 8 1 2 2 3 7 1 3 2 4 16 MOUNTING PLANUX MONITOR ART 20034801 WITH FLUSH MOUNTED BOX ART 6117 DISASSEMBLY...

Страница 44: ...44 3 145 150 cm 115 125 cm 2 14 5 cm 14 5 cm 1 6 5 4 9 2 2 1 3 8 7 10 4 17 MOUNTING PLANUX MONITOR ART 20034801 WITH WALL SUPPORT ART 6120 DISASSEMBLY...

Страница 45: ...3310W 4A 7 160 cm 130 cm 1 2 2 1 2 6 14 2 cm 14 7 cm 2 1 2 1 1 2 1 2 CLACK 1 2 1 3B 3A 5A 8 3C 4 18 WALL MOUNTING ICONA MANAGER VIP ART 6620 SU 503 SERIES BOX ROUND BOX DISASSEMBLY Art 6620 optional w...

Страница 46: ...6 2 1 1 1 2 CLACK 2 3 6 9 160 cm 130 cm Lmax 10 cm Lmin 6 cm 1 2 Art 20003310W 2 5 8 14 2 cm 14 7 cm 2 3 4 5 1 2 1 1 2 1 4 7 4 19 MOUNTING ICONA MANAGER VIP ON A FLUSH MOUNTED BOX ART 6117 DISASSEMBLY...

Страница 47: ...1 2 1 2 1 2 1 1 3 2 VEDO8I8O VEDORF 3 1 2 2 1 4 20 PREPARING THE PLASTIC HOUSING FOR MOUNTING THE EXPANSION ART VEDORF VEDO8I8O 4 21 WALL MOUNTING THE PLASTIC HOUSING FOR MOUNTING THE EXPANSION ART V...

Страница 48: ...next level or to confirm the entry of a new data item Press C to return to the previous menu To modify a numerical value type in the desired value following the format shown on the display omitting no...

Страница 49: ...st line will show DD MM YY day month and year and the second line will display the date set on the control panel 5 Enter the date using the number keys e g 1 September 2012 becomes 010912 then confirm...

Страница 50: ...keypad remember to transfer them to the PC by means of the Comelit alarm control panels configuration programme 1 Disconnect the siren battery if connected and disconnect the audio from its connector...

Страница 51: ...u depth level you are it is possible to use fast navigation by inserting the coordinates The coordinates are inserted in pairs of lines or columns for each navigation depth level Each coordinate is co...

Страница 52: ...on 1 1 1 7 x 2 Tamper areas At least one selected area 1 1 1 7 x 3 Technical areas At least one selected area 1 1 1 7 x 4 Tamper cycles Unlimited 1 1 1 7 x 5 Technical cycles Unlimited 1 1 1 7 x 8 Unl...

Страница 53: ...Radio zones Vedo 10 x from 1 to 16 Vedo 34 x from 1 to 64 Vedo 68 x from 1 to 96 Indices Parameters Configurations necessary to guarantee Grade 2 certification 1 1 1 13 x 3 Monitoring Maximum 20 minut...

Страница 54: ...ognition timeout 60 seconds 1 1 1 27 1 9 Telephone line parameters pstn Selected 1 1 1 27 1 10 Length of call 60 seconds 1 1 1 27 1 12 Voice message repetition 5 1 1 1 27 1 14 Attempts 3 1 1 1 27 1 15...

Страница 55: ...Action Only set selected 1 1 1 31 x 6 y 155 Panic Alarm Action Only set selected 1 1 1 31 x 6 y 156 Robbery Alarm Action Only set selected 1 1 1 31 x 6 y 157 Flood Alarm Action Only set selected 1 1...

Страница 56: ...eset alarms Selected 1 1 1 43 x 114 Stop alarms Selected 1 1 1 43 x 115 Stop telephone calls Selected 1 1 1 43 x 116 Timed activation error Selected 1 1 1 43 x 119 Technical programming Selected 1 1 1...

Страница 57: ...ES n X 0 22 mm2 0 50 0 085 8 5 n X 0 50 mm2 0 80 0 032 3 2 n X 0 75 mm2 0 90 0 026 2 6 n X 1 mm2 1 0 020 2 n X 1 5 mm2 1 28 0 013 1 3 n X 2 5 mm2 1 65 0 008 0 82 For the bus signals A and B you can us...

Страница 58: ...to go through a hub or a network switch The control panel will be connected by means of a network cable in straight configuration In many cases it will be possible to buy a standard cable of suitable...

Страница 59: ...59...

Страница 60: ...w w w c o m e l i t g r o u p c o m Passion Technology Design 3rd edition 10 2015 code 2G40001435 8 8 023903 023903 306743 306743...

Отзывы: