![Comelit VEDO10 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/comelit/vedo10/vedo10_technical-manual_2640394052.webp)
52
5.5.1 Keypads
Vedo 10
x: from 1 to 2 /
Vedo 34
x: from 1 to 8 /
Vedo 68
x: from 1 to 8
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.1.x.2
Checked areas
At least one selected area
1.1.1.1.x.4
Tamper areas
At least one selected area
1.1.1.1.x.5
Technical areas
At least one selected area
1.1.1.1.x.16
Buzzer on
Active
1.1.1.1.x.17
Entrance Buzzer
Active
1.1.1.1.x.18
Exit Buzzer
Active
1.1.1.1.x.19
Alarm Buzzer
Active
1.1.1.1.x.22
Pre-alert Buzzer
Active
1.1.1.1.x.24
System status display time
0 (+30 seconds)
1.1.1.1.x.25
Tamper cycles
Unlimited
1.1.1.1.x.26
Technical cycles
Unlimited
1.1.1.1.x.27
Unlimited System status
display time
Deselected
1.1.1.1.x.28
Unlimited tamper cycles
Selected
1.1.1.1.x.29
Unlimited technical cycles
Selected
1.1.1.1.x.30
System device
Not used
1.1.1.1.x.33
Quick activation
Deselected
1.1.1.1.x.35
Area status
Selected
1.1.1.1.x.37
Zones open
Selected
1.1.1.1.x.41
Send Digital Com
Selected
1.1.1.1.x.43
Buzzer ActDeact
Selected
1.1.1.1.x.44
Buzzer Act.Failed
Selected
5.5.2 App
x: from 1 to 8
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.5.x.2
Controllable areas
At least one selected area
1.1.1.5.x.3
Tamper areas
At least one selected area
1.1.1.5.x.4
Tamper cycles
Unlimited
1.1.1.5.x.10
Send digital communication
Selected
1.1.1.5.x.12
Unlimited tamper cycles
Selected
1.1.1.5.x.23
Unlimited start-up time
Deselected
5.5.3 Input/output expansions (8I8O)
Vedo 10
x: not available /
Vedo 34
x: from 1 to 8 /
Vedo 68
x: from 1 to 12
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.7.x.2
Tamper areas
At least one selected area
1.1.1.7.x.3
Technical areas
At least one selected area
1.1.1.7.x.4
Tamper cycles
Unlimited
1.1.1.7.x.5
Technical cycles
Unlimited
1.1.1.7.x.8
Unlimited tamper cycles
Selected
1.1.1.7.x.9
Unlimited technical cycles
Selected
1.1.1.7.x.12
Send Digital Com
Selected
5.5.4 Power supply stations
Vedo 10
x: from 1 to 1 /
Vedo 34
x: from 1 to 4 /
Vedo 68
x: from 1 to 8
Indices
Parameters
Configurations necessary to
guarantee Grade 2 certification
1.1.1.8.x.2
Tamper Areas
At least one selected area
1.1.1.8.x.3
Technical Areas
At least one selected area
1.1.1.8.x.4
Tamper cycles
Unlimited
1.1.1.8.x.5
Technical cycles
Unlimited
1.1.1.8.x.7
Unlimited tamper cycles
Selected
1.1.1.8.x.8
Unlimited technical cycles
Selected
1.1.1.8.x.11
Send digital
communications
Selected
1.1.1.8.x.13
Tamper enabled
Selected
1.1.1.8.x.14
Network alarm delay
Max 60 seconds
1.1.1.8.x.15
Battery alarm delay
Max 5 minutes
This chapter provides indications on the configuration parameters
which, if varied, could lower the safety level of the system, and the
configurations necessary to guarantee I&HAS certification.
For further details on programming and configuration,
consult the programming technical manual (downloadable
from the website www.comelitgroup.com).
5.5 CONFIGURATIONS NECESSARY TO
GUARANTEE GRADE 2 CERTIFICATION
ACCORDING TO EN50131-1
Fast navigation
Indices
Parameters
1.1.
1.1.x.16
Buzzer on
1.
Consult the table with the indices of the parameters* and
find the index of the desired function, starting from the
current depth level
2. Type in the
index as follows, pressing prog at "." and
pressing
at the end of the sequence:
* the following pages show only the indices of the parameters
to be configured to obtain grade 2 certification according to
EN50131-1.
1
1
1
16
LEVEL 3
LEVEL 2