3.13 POWER SUPPLY STATIONS
3.13.1 Power supply unit management card for
VEDO series control panels Art. PCBPSU
This device can be used to expand Vedo series systems by
providing:
• The auxiliary power supplies
provided by the card are
acquired by the mains power supply units connected
to connector CN1.
• The Open Collector outputs
are configured to provide
fault and anomaly indications.
• If the power supply unit is not connected to a control panel,
the indication delay times are as follows: power supply
network alarm delay=1 minute, battery alarm delay=5
minutes.
• When the device is connected to a Vedo series control
panel, it is possible to monitor the status of the auxiliary
power supplies and the power supply unit itself. In this case
network alarm delay and battery alarm delay times can be
configured (using the Safekey keypad or the Safe Manager
software).
• A new branch to the RS485 data BUS, electrically isolated
with the corresponding power supply output.
• 2 auxiliary power supply outputs.
• 4 Open Collector indication outputs.
• One terminal for tamper contact.
1.
CN1 PSU connector
2.
CN2 Battery connector"
3.
Outputs
4.
Outputs Power Supply
5.
Data BUS out
6.
Data BUS in
Holes for fixing the PCBPSU card to the metal housing BOXMETAL.
MAIN FEATURES
Art. PCBPSU complies with standards EN50131-1,
EN50131-3, EN50131-6, EN 60950-1:2006 + A11:2009 +
A1:2010 + A12:2011, EN50130-4:2011
TECHNICAL SPECIFICATIONS
Features Value
Name of manufacturer / supplier
Comelit Group S.p.A.
Dimensions (b x h x d)
140x127x23mm
Weight
115gr
Housings supported
Art.
BOXPLASTIC
Art. BOXMETAL
Power supply units supported
PSU15
PSU15
PSU50
Batteries supported
Art. 30076003
12V/7Ah
Art. 30076003
12V/7Ah
Art. 30076004
12V and 18Ah
Max. battery charging current
0.8A
Battery 80% charging time
8h
8h/19h
Low Battery Fault Generation in
presence of EPS
12V
* Respecting any indications for configuration and installation
TERMINAL BLOCK M1-M2-M3-M4-M5-M6
Name Function
Earth
Earth connection terminal
bus IN
V+
485 communication BUS power supply input positive
V-
485 communication BUS power supply input negative
A
RS485 data BUS for connection to the control panel (IN) - A
B
RS485 data BUS for connection to the control panel (IN) - B
bus OUT
V+
Power supply positive output. 485 communication bus. Limited to 1.5A
V-
Power supply negative - output reference. 485 communication BUS
power supply
A
RS485 data BUS for connection to other devices (OUT) - A
B
RS485 data BUS for connection to other devices (OUT) - B
bus OUT
V+
Power supply positive output. 485 communication bus. Limited to 1.5A
V-
Power supply negative - output reference. 485 communication BUS
power supply
A
RS485 data BUS for connection to other devices (OUT) - A
B
RS485 data BUS for connection to other devices (OUT) - B
OUTPUTS POWER SUPPLY
V+AUX1
Auxiliary 1 power supply output positive. Limited to 1.5A
V-
Auxiliary 1 power supply output negative
V+AUX2
Auxiliary 2 power supply output positive. Limited to 1.5A
V-
Auxiliary 2 power supply output negative
24H Tamper contact input
OUTPUTS
O1 Open Collector Output 1.
Programmed as module Anti-Sabotage by
default. The output is active when module sabotage occurs.
O2 Open Collector Output 2.
Programmed as module Low Battery
Anomaly by default. The output is active when the programmed time
has elapsed since the moment at which the battery was no longer
detected or the does not respect the values indicated in the technical
specifications.
O3 Open Collector Output O3.
Programmed as module No 230V Mains
Anomaly by default. The output is active when the programmed time
has elapsed since the moment at which the network was no longer
detected.
O4 Open Collector Output O4.
Programmed by default to indicate the
fault of the power supply unit or of the power supply outputs. The
output is active when there is a fault in the power supply unit or on the
power supply outputs V+bus, VAUX1 or VAUX2
For the Technical Specifications linked to the type of power supply unit,
see paragraph 1.2.4.
Low Battery Fault Generation in
absence of EPS
11.5V
Switch-off Art. PCBPSU in absence
of EPS for Protection against Deep
Discharges
10.5V
Intervention voltage of the protection
against
voltage surges: battery
disconnection
15V
Maximum current for Outputs
V+BUS OUT,V+AUX1, V+AUX2
1.5A
Output voltage operating range
(V+BUS OUT,V+AUX1,V+AUX2)
10-15V
CN1 input voltage operating range
12.8-15V
CN2 input voltage operating range
(Battery)
10.5-15V
Control panel card consumption
Art. PCBPSU (min./max.)
15/20mA
Maximum current available for
external devices Grade 2:
550mA
Grade 2:
1.45A
Maximum current delivered to
outputs TC1 and TC2
100mA
Operating temperature and Operating
humidity
-10° / + 55° with warm dry air
-10° / + 40° C with max + 93% RH
(not condensed)
Certifiable safety grade
2 according to EN50131-1*
Type of power supply unit
TYPE A according to standard
EN50131-6
Environmental class
II according to EN50131-1