2201R Mobile Tester SCPI Reference Guide
Chapter 8 Configuration commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
98
:CONFigure:GSM:MSTAtion:TADVance
Syntax
:CONFigure:GSM:MSTAtion:TADVance <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 63. The default value for int1 is 0.
Description
This command sets the timing advance for the mobile under test to use. The current setting of the timing advance is
broadcast to the mobile in the SACCH physical header.
Query
The query form of this command returns the current setting. The string delivered back contains one integer.
Example
:CONFigure:GSM:MSTAtion:TADVance 12
:CONF:GSM:MSTA:TADV?
Value returned: "12".
:CONFigure:GSM:MSTAtion:PLEVel[:ALL]
Syntax
:CONFigure:GSM:MSTAtion:PLEVel[:ALL] <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 31. The default value for int1 is 10.
Description
This command sets the mobiles power control level.
Notes
The RF power control level is a code. The corresponding RF output power of the mobile under test depends on the
type of GSM system and the frequency range.
The power control level is broadcast in the SACCH physical header.
Query
The query form of this command returns the current setting. The string delivered back contains one integer.
Example
CONFigure:GSM:MSTAtion:PLEVel:ALL 17
:CONF:GSM:MSTA:PLEV?
Value returned: "17".