2201R Mobile Tester SCPI Reference Guide
Chapter 6 Status commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
78
:STATus:OPERation:MEASuring:NTRansition
Syntax
:STATus:OPERation:MEASuring:NTRansition <int1>
Parameters
int1 is an integer. The minimum value for int1 is 0, the maximum value is 32767. The default value is 0.
Description
Sets the NTR mask of the Measuring operation register group. This mask is ANDed with the up to 16 bits of the NTR
filter of the measuring operation condition register to allow a reset (negative transition) of any bit (i.e. a transition
from logic 1'to'0')toreachthemeasuringoperationeventregister.'
Note: The default of this mask is 0 — that means that the mask does not allow any negative transition of the 16 bits
of the condition-type register to reach the event-type register of this group.
Query
There is no query form of this command available.
Example
:STATus:OPERation:MEASuring:NTRansition 0
This means that none of the negative transitions of the condition-type register are forwarded to the event-type
register.