2201R Mobile Tester SCPI Reference Guide
Chapter 10 Measurement commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
215
GSM/GPRS commands
Please note that the accuracy specified for multislot transmitter measurements applies to the time slot with the
highest power level. The accuracy of results at levels of more than 10 dB below the highest power level may be
significantly lower.
:MEASure:GPRS[:CONTinuous]:RFTX:STOP
Syntax
:MEASure:GPRS[:CONTinuous]:RFTX:STOP
Parameters
There are no parameters.
Description
Stops continuous RF transmitter measurements.
Note
Stopping the test is not required since a test is automatically stopped when you start a new test.
Query
The query form of this command is not available.
Example
:MEAS:GPRS:RFTX:ALL
:MEAS:GPRS:RFTX:STOP
Starts and stops a measurement.