2201R Mobile Tester SCPI Reference Guide
Chapter 6 Status commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
76
:STATus:OPERation:MEASuring[:EVENt]?
Syntax
:STATus:OPERation:MEASuring[:EVENt]?
Parameters
There are no parameters.
Description
Reads out the current contents of the measuring operation event register.
Note: Event-type registers are read-only and self-destructive. They are cleared after any query.
Query
There is only a query form of this command available. The query returns a string, containing one integer. The value
returned represents all measuring operation events that have occurred since the last query of this register. As with
any event-type register, the single bits remain set even when the reason for the bits to be set is no longer valid. Please
note that this is the main difference between event-type and condition-type registers. Condition-type registers
reflect the current state of the 2201R. Consequently, the condition type registers are updated continuously.
Note: In case a certain event is trapped in a loop within a program, always query the event-type register.
Example
:STATus:OPERation:MEASuring:EVENt?
Value returned: "8".
This means that bit 3 (stands for AF measurement) has been set.
:STATus:OPERation:MEASuring:CONDition?
Syntax
:STATus:OPERation:MEASuring:CONDition?
Parameters
There are no parameters.
Description
This command reads out the current contents of the measuring operation condition register. This register reflects the
current state of the 2201R in terms of measurements and is updated continuously.
Note: This register is nondestructive. This means that it keeps its contents after any query.
Query
There is only a query form of this command available. The query returns a string, containing one integer. The integer
expresses all bits set in the 16 bit measuring operation condition register.
Note: Bits 4 to 15 (the MSB) of this register are not used. Therefore, the maximum value returned is "7".
Example
:STATus:OPERation:MEASuring:CONDition?
Value returned: "1".
This means that bit 0 has been set and that there is an RFTX measurement currently in progress. This bit is reset as
soon as the RFTX measurements have been completed.