2201R Mobile Tester SCPI Reference Guide
Chapter 10 Measurement commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
257
Example
:MEASure:EGPRs:ARRay:RFTX:ALL 2
:FETCh:EGPRs:RFTX:ALL?
In this case, the sequence of the most important EGPRS RF TX measurements is performed twice. All 34 measurement
result values are kept in an internal memory until they are read out with the FETCh command. After the internal
memory has been read out, it is cleared.
Note: A subsequent :FETCh command (without any previous start of a measurement) therefore tries to read
non-existing measurement data and thus create a timeout error.
:MEASure:EGPRs:ARRay:RFTX:ERMS
Syntax
:MEASure:EGPRs:ARRay:RFTX:ERMS <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 100. The default value for int1 is 0.
Description
Measures multiple times (set with the int1 parameter) the error vector magnitude rms-averaged over a burst. EVM is
a relative value and shown as a percentage. To read out the entire measurement results array, use the
:FETCh:EGPRs:RFTX:ERMS command.
Query
The query form of this command returns a string, containing int1 floating point real numbers with the physical
dimension of %, representing the measurement results.
The single measurement results are separated by commas.
Example
:MEAS:EGPRs:ARR:RFTX:ERMS 5
:FETC:EGPRs:RFTX:ERMS?
The error vector magnitude rms-averaged measurement is performed five times. The measurement results are stored
internally and read by the FETC command. An example of the string returned is: "2.33,2.53,1.97,2.41,1.79".