2201R Mobile Tester SCPI Reference Guide
Chapter 8 Configuration commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
151
:CONFigure:EGPRs:BS:NCELl
Syntax
:CONFigure:EGPRs:BS:NCELl <int1>,<int2>,<int3>,<int4>,<int5>,<int6>
Parameters
int1 to int6 are integers.
The minimum value for each intx is 0, the maximum value is 1023. The default value for each intx is 0.
Description
This command is used to set the channel numbers for up to six neighboring cells. These channel numbers are
broadcast in the system information message by the 2201R. The mobile under test has to perform a MS report on
those frequency channels.
Notes:
All six integer values are optional. If the command is sent without any channel number specified, the default values
(=0) are broadcast by the 2201R in the system information message.
Assume that there was a first command sent with six channel numbers specified. After that, a second command is
sent with only two channel numbers specified. Now, the 2201R alters only the first two channel numbers and
maintains all other settings (see example below for details).
Query
The query form of this command always returns the complete set of neighboring channel numbers currently in use.
The string delivered back always contains six integers.
Example
:CONFigure:EGPRs:BS:NCELl 10,20,30,40,50,60
:CONF:EGPRs:BS:NCEL 70,80
:CONF:EGPRs:BS:NCEL?
Values returned in this example: "70,80,30,40,50,60".