:CONFigure:GPRS:BLER:PDUCount
Syntax
:CONFigure:GPRS:BLER:PDUCount <int1>
Parameters
int1 is an integer parameter.
The minimum value for int1 is 0, the maximum value is 4095. The default value for int1 is 4095.
Description
Defines the number of PDUs as defined in ETSI TS 101 293 / 8.13. Applies to BLER measurements in GPRS
synchronous mode.
Query
The query form of this command returns the current setting. The string delivered back contains one integer.
Example
:CONFigure:GPRS:BLER:PDUCount 1000
:CONF:GPRS:BLER:PDUCount?
Value returned: "1000".
:CONFigure:GPRS:BER:LOOP
Syntax
:CONFigure:GPRS:BER:LOOP <PredefExp>
Parameters
PredefExp is one of the following predefined expressions: NONResidual|RESidual|FAST.
Default is NONResidual.
Description
This command sets the type of BER loop (inside the mobile under test) to be used for bit error measurements.
NONResidual means that a standard bit error ratio test is performed. This test is called BER on the graphical user
interface of the 2201R.
RESidual sets up the test loop of a residual bit error ratio measurement. This test is called RBER on the graphical user
interface of the 2201R.
FAST means that a fast bit error ration measurement is performed. This test is called FastBER on the graphical user
interface of the 2201R.
Query
The query form of this command returns the current setting. The string delivered back contains the short-form
version of one of the predefined expressions explained above.
Example
:CONFigure:GPRS:BER:LOOP RESidual
:CONF:GPRS:BER:LOOP?
Value returned: "RES".