2-12
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
Chapter
NIC Modes and NIC Redundancy Settings
This server has the following NIC mode settings that you can choose from:
•
Dedicated—The two 10/100 management ports are used to access the CIMC. You have to select a
NIC redundancy and IP setting.
•
Shared LOM (default)—The two 1Gb Ethernet ports are used to access the CIMC. This is the factory
default setting, along with Active-active NIC redundancy and DHCP enabled.
•
Cisco Card—The ports on an installed Cisco network adapter card are used to access the CIMC. You
have to select a NIC redundancy and IP setting.
Note
The Cisco Card NIC mode is currently supported only with a Cisco UCS P81E Virtual Interface
Card (N2XX-ACPCI01) that is installed in PCIe slot 1 (see
Figure 3-18 on page 3-34
). See also
Special Considerations for the Cisco UCS P81E Virtual Interface Card (N2XX-ACPCI01),
page 3-35
.
This server has the following NIC redundancy settings that you can choose from:
•
None—The Ethernet ports operate independently and do not fail over if there is a problem.
•
Active-standby—If an active Ethernet port fails, traffic fails over to a standby port.
•
Active-active—All Ethernet ports are utilized simultaneously.
Содержание UCS C210
Страница 12: ...xii Cisco UCS C210 Server Installation and Service Guide OL 20887 02 ...
Страница 14: ...xiv Cisco UCS C210 Server Installation and Service Guide OL 20887 02 ...
Страница 38: ...2 20 Cisco UCS C210 Server Installation and Service Guide OL 20887 02 Chapter ...
Страница 92: ...B 8 Cisco UCS C210 Server Installation and Service Guide OL 20887 02 Appendix ...
Страница 100: ...C 8 Cisco UCS C210 Server Installation and Service Guide OL 20887 02 Appendix ...