D-9
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
Appendix
Note
These UCSM mode settings enable DHCP, Active-Active NIC redundancy, and Shared LOM
NIC mode, which enables CIMC control through the 1Gb LOM ports, rather than the
management port. Any static IP addresses and the management port are disabled, so you lose
connection with the CIMC. To connect the server to your Cisco UCS FEXes and FIs, continue
with
2. Physically Connecting the Server to the Cisco UCS Environment, page D-9
.
2. Physically Connecting the Server to the Cisco UCS Environment
Use the following procedure to connect the Cisco UCS C210 M2 server to the Cisco UCS environment.
Step 1
Connect the management traffic paths from the server to the FEXes (see
Figure D-3
):
a.
Insert one GLC-T transceiver into a port of the FEX in Fabric A. You can use any port on the FEX.
b.
Insert one GLC-T transceiver into a port of the FEX in Fabric B. You can use any port on the FEX.
c.
Connect an RJ-45 Ethernet cable between 1-Gb port Eth1 or Eth 2 on the rear panel of the server
and the transceiver that you inserted into the FEX in Fabric A.
d.
Connect an RJ-45 Ethernet cable between 1-Gb port Eth1 or Eth 2 on the rear panel of the server
and the transceiver that you inserted into the FEX in Fabric B.
Step 2
Connect the data traffic paths from the server to the FEXes (see
Figure D-3
):
a.
Connect a 10-Gb SFP cable between the 10-Gb adapter card in the server and a port on a FEX in
Fabric A. You can use any port on the FEX.
b.
Connect a 10-Gb SFP cable between the 10-Gb adapter card in the server and a port on a FEX in
Fabric B. You can use any port on the FEX.
Step 3
Connect the paths from the FEXes to the FIs. These paths carry both data and management traffic.
Note
The maximum number of uplinks is eight. The port cabling requirements between the FEX and the FI
vary, depending on whether your UCS Manager FI discovery policy is set to hard-pinning mode or
port-channel mode. See
Hard-Pinning Mode and Port-Channel Mode Discovery Policies, page D-2
.
a.
Connect two 10-Gb SFP cables between FEX A and two ports on FI A. You can use any ports on FI
A, but the ports must be enabled for server traffic.
b.
Connect two 10-Gb SFP cables between FEX B and two ports on FI B. You can use any ports on FI
B, but the ports must be enabled for server traffic.
Step 4
Reboot the server.
Step 5
To view and configure settings for the server from within the Cisco UCS Manager software, see the
information instructions in the
Cisco UCS Manager Configuration Guide, Release 2.0
or later.
Содержание UCS C210
Страница 12: ...xii Cisco UCS C210 Server Installation and Service Guide OL 20887 02 ...
Страница 14: ...xiv Cisco UCS C210 Server Installation and Service Guide OL 20887 02 ...
Страница 38: ...2 20 Cisco UCS C210 Server Installation and Service Guide OL 20887 02 Chapter ...
Страница 92: ...B 8 Cisco UCS C210 Server Installation and Service Guide OL 20887 02 Appendix ...
Страница 100: ...C 8 Cisco UCS C210 Server Installation and Service Guide OL 20887 02 Appendix ...