3-38
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
Chapter
f.
Press down evenly on both ends of the assembly to fully engage the riser cards with the PCIe slots
on the motherboard.
g.
Replace the screw that secures the assembly to the chassis.
h.
Replace the top cover.
i.
Replace the server in the rack, replace power cords and any other cables, and then power on the
server by pressing the
Power
button.
Step 3
Restore the RAID configuration on your drives to the new mass storage controller.
See
Restoring RAID Configuration After Replacing a RAID Controller, page C-6
.
Figure 3-21
Removing and Replacing a PCIe Card
1
Riser card assembly removed from chassis
2
Riser card
3
PCIe card
4
PCIe card rear plate
5
Securing screw (attaches to assembly)
195926
5
1
2
3
4