3-31
Cisco UCS C210 Server Installation and Service Guide
OL-20887-02
Chapter
On the BIOS utility screen, select the
Security
tab, then select
Set Administrator Password
. Use
the pop-up boxes to set the BIOS administrator password, then press
F10
to save your settings and
reboot the server.
f.
Watch during bootup for the F2 prompt, and then press
F2
to enter BIOS setup.
g.
Log into the BIOS Setup utility with your BIOS Administrator password.
h.
On the BIOS utility screen, select the
Security
tab.
i.
Scroll down to
TPM
and select
TURN ON
.
j.
Press
F10
to save your settings and reboot the server.
k.
Watch during bootup for the F2 prompt, and then press
F2
to enter BIOS setup.
l.
Log into the BIOS Setup utility with your BIOS Administrator password.
m.
Verify that the TPM is now enabled. Select the
Security
tab. Verify that the TPM entry now says
Enabled.
Replacing a PCIe Riser Card Assembly
The qualified and supported part numbers for this component are subject to change over time. For the most
up-to-date list of replaceable components, see the following URL and then scroll to
Technical Specifications
:
http://www.cisco.com/en/US/products/ps10493/products_data_sheets_list.html
To replace a PCIe riser card assembly, follow these steps:
Step 1
Remove a PCIe riser card assembly:
a.
Power off the server as described in the
“Shutting Down and Powering Off the Server” section on
page 3-8
.
b.
Disconnect all power cords from the power supplies.
c.
Slide the server out the front of the rack far enough so that you can remove the top cover. You might
have to detach cables from the rear panel to provide clearance.
Caution
If you cannot safely view and access the component, remove the server from the rack.
d.
Remove the top cover as described in the
“Removing and Replacing the Server Top Cover” section
on page 3-10
.
Note
Older servers have a screw that secures the PCIe riser to the rear of the chassis, but newer servers
do not have this screw. If your server has the screw, continue with the next step to remove it. If
your server does not have this screw, skip to Step
f.
e.
Remove the screw that holds the riser card assembly to the rear of the chassis.
f.
Lift the assembly and any attached PCIe cards straight up and out of the chassis. Lift up on both
ends of the assembly evenly to avoid damaging the sockets or the riser cards (see
Figure 3-17
).
g.
Remove any PCIe card from the riser card and set it aside. See
Replacing a PCIe Card (Network
Adapters), page 3-33
.
Содержание UCS C210
Страница 12: ...xii Cisco UCS C210 Server Installation and Service Guide OL 20887 02 ...
Страница 14: ...xiv Cisco UCS C210 Server Installation and Service Guide OL 20887 02 ...
Страница 38: ...2 20 Cisco UCS C210 Server Installation and Service Guide OL 20887 02 Chapter ...
Страница 92: ...B 8 Cisco UCS C210 Server Installation and Service Guide OL 20887 02 Appendix ...
Страница 100: ...C 8 Cisco UCS C210 Server Installation and Service Guide OL 20887 02 Appendix ...