3-5
Cisco SFS 3504 Multifabric Server Switch Hardware Installation Guide
OL-14325-01
Chapter 3 Installing the Cisco SFS 3504 Server Switch
Mounting the Cisco SFS 3504 Server Switch on a Rack
Installing with the Power-Fan Modules Flush-front
To install the Cisco SFS 3504 Server Switch on a rack so that the power-fan module end is flush mounted
to the front rack posts, perform the following steps:
Step 1
Open the bag that contains the mounting hardware.
Note
To mount a Cisco SFS 3504 Server Switch on a rack, use eight screws and eight nuts. These
screws and nuts must be supplied by the customer, based upon compatibility of the screws and
nuts with the specific rack.
Step 2
Attach the two rack ear brackets to the power-fan module end of the chassis using a Phillips screwdriver and
the six
M4 x 8 mm.
flathead screws provided (three on each side), as shown in
Figure 3-1
. Use the three holes
of the rack ear brackets. Firmly tighten the screws on the rack ear brackets to secure them to the chassis.
Figure 3-1
Attaching the Rack-Mounting Ear Brackets at the Power-Fan Module End
250376
INPUT
OK
FAN
OK
OUTPUT
FAIL
SFS3500
Series
CAUTION: D
ISCONNECT P
OWER BEFO
RE SERVICIN
G
!
ALL FASTENE
RS MUST BE
FULLY ENGA
GED PRIOR T
O
OPERATION
OF POWER S
UPPLY
100-240V
8-4A
50/60Hz
INPUT
OK
FAN
OK
OUTPUT
FAIL
SFS3500
Series
CAUTION: D
ISCONNECT P
OWER BEFO
RE SERVICIN
G
!
ALL FASTEN
ERS MUST B
E
FULLY ENGA
GED PRIOR T
O
OPERATION
OF POWER
SUPPLY
100-240V
8-4A
50/60Hz
1
1
2
1
Rack ear brackets
2
Guide rails (pre-installed)