Description
Status
LED
Component
All diagnostics pass. The
module is operational.
Solid on (green)
Status
Fan
The module is not
receiving power.
Off
The module is booting or
running diagnostics.
Solid on (amber)
If the module fails during
an initial reset, the LED
continues to blink and the
module does not come
online.
The module has a runtime
failure and is brought
offline.
Blinking (amber)
Power Supply LEDs
This table provides information about power supply LEDs for Cisco Nexus 3000 Series switches.
Description
Status
LED
Component
Power supply is on and
okay.
Solid on
OK (green)
Power supply
3.3 voltage standby (VSB)
is on but the power supply
unit is not powering the
other modules.
Blinking
No power to the power
supply.
Off
Power supply failure,
overvoltage, overcurrent,
or overheating.
Solid on
FAULT (amber)
Power is present, 3.3 VSB
on, and the power supply
is off.
PSU fan rotor is not
functioning normally.
Blinking
Operating normally.
Off
Cisco Nexus 3400 Hardware Installation Guide
60
LEDs
Power Supply LEDs
Содержание Nexus 3400 Series
Страница 6: ...Cisco Nexus 3400 Hardware Installation Guide vi Contents ...
Страница 8: ...Cisco Nexus 3400 Hardware Installation Guide viii Preface Related Documentation ...
Страница 14: ...Cisco Nexus 3400 Hardware Installation Guide 6 Preparing the Site Dust and Contaminants ...
Страница 46: ...Cisco Nexus 3400 Hardware Installation Guide 38 Installing the Chassis Starting the Switch ...
Страница 58: ...Cisco Nexus 3400 Hardware Installation Guide 50 Replacing Modules Replacing a DC Power Supply ...
Страница 64: ...Cisco Nexus 3400 Hardware Installation Guide 56 System Specifications HVDC Power Cable Specifications ...
Страница 72: ...Cisco Nexus 3400 Hardware Installation Guide 64 Spare Parts Table Spare Parts Table ...