background image

C H A P T E R

2

Preparing for Installation

The following sections describe how to prepare for the installation of the Cisco ASR 907 Router at your site:

Safety Guidelines, on page 31

Site Planning, on page 39

Receiving the Cisco ASR 907 Router, on page 50

Safety Guidelines

Before you begin the installation of the Cisco ASR 907 Router, review the safety guidelines in this chapter
to avoid injuring yourself or damaging the equipment.

In addition, before replacing, configuring, or maintaining the Cisco ASR 907 Router, review the safety
warnings listed in Regulatory Compliance and Safety Information for the Cisco ASR 900 Series Aggregation
Routers.

Standard Warning Statements

To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and
Safety Information document that accompanied this device.

To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to
ensure that the system remains stable. The following guidelines are provided to ensure your safety: This unit
should be mounted at the bottom of the rack if it is the only unit in the rack. When mounting this unit in a
partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of
the rack. If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing
the unit in the rack. Statement 1006

Warning

This unit is intended for installation in restricted access areas. A restricted access area can be accessed only
through the use of a special tool, lock and key, or other means of security. Statement 1017

Warning

Cisco ASR 907 Router Hardware Installation Guide

31

Содержание ASR 907

Страница 1: ... Installation Guide First Published 2015 10 01 Last Modified 2019 07 31 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 ...

Страница 2: ... 2015 2019 Cisco Systems Inc All rights reserved ...

Страница 3: ...ported RSP Features 8 Supported Interface Modules 9 RSP Redundancy 12 Network Timing Interfaces 12 RSP Interfaces 13 Interface Modules 13 8 Port 1 Gigabit Ethernet SFP Interface Module A900 IMA8S 14 8 Port 1 Gigabit Ethernet RJ45 Interface Module A900 IMA8T 15 1 Port 10 Gigabit Ethernet XFP Interface Module A900 IMA1X 15 8 port 10 Gigabit Ethernet Interface Module 8x10GE A900 IMA8Z 16 8 Port 1 Gig...

Страница 4: ... 48 Port T3 E3 CEM Interface Module A900 IMA48T C 24 1 port OC 48 STM 16 or 4 port OC 12 OC 3 STM 1 STM 4 12 Port T1 E1 4 Port T3 E3 CEM Interface Module A900 IMA3G IMSG 25 1 Port OC 192 or 8 Port Low Rate CEM Interface Module 10G HO 10G LO A900 IMA8S1Z CX 25 ASR 900 Combo 8 Port SFP GE and 1 Port 10GE With CEM iMSG 20G Interface Module A900 IMA1Z8S CXMS 27 Temperature Sensor 29 Interface Numberin...

Страница 5: ...g a Site Log 50 Receiving the Cisco ASR 907 Router 50 Chassis Lifting Guidelines 51 Tools and Equipment 52 Unpacking and Verifying the Shipped Contents 53 Installing the Cisco ASR 907 Router 55 C H A P T E R 3 Prerequisites 55 Installing the Router in a Rack 55 Installing the Chassis Brackets 55 Installing the Router Chassis in the Rack 56 Installing Plenum A907 F2B AIR U Assembly and Chassis in t...

Страница 6: ...le 84 Connecting DC Power Supply Unit A900 PWR900 D2 85 Activating the DC Power Supply 87 Removing and Replacing the DC Power Supply 88 Installing the AC power Supply 89 Installing the AC Power Supply Module for A900 PWR1200 A 1200 W 89 Recommended Power Cables 90 Activating the AC Power Supply 91 Removing and Replacing the AC Power Supply 91 Installing Dust Caps 92 Connecting the Cisco ASR 907 Ro...

Страница 7: ...outs 109 RJ45 Cable Pinouts 109 RJ48 Cable Pinouts 109 Connecting Cables to the Patch Panel 109 Patch Panel Pinout 110 Patch Panel Cabling for Redundancy 110 Recommended Patch Panel 112 Installing Patch Panel 113 Install 3G Patch Panel 117 Install Rack Brackets 118 Set up 3G Patch Panel on Rack 125 Wall Mount 3G Patch Panel 137 Patch Panel Dimensions 139 Connecting Serial Cables 144 Connecting the...

Страница 8: ... Pinout 158 Alarm Port Pinout 159 Console Aux RJ45 RS232 Serial Port Pinout 159 T1 E1 Port Pinout 160 16 T1 E1 Interface Module Pinout 160 32 T1 E1 Interface Module Pinout 162 8 T1 E1 Interface Module RJ48C Port Pinnouts 165 AMP64 Pinouts 166 Patch Panel Pinout 171 Serial Cable Pinouts 176 DB 9 Connector Pinouts 176 RJ 45 Connector Pinouts 177 RJ 48 Connector Pinouts 178 Management Ethernet Port P...

Страница 9: ...3 Interface Module LEDs 185 OC 3 Interface Module LEDs 186 T1 E1 Interface Module LEDs 186 Serial Interface Module LEDs 189 Power Supply LEDs 189 Fan Tray LEDs 190 Alarm Conditions 191 Site Log and Manufactures 193 A P P E N D I X A Manufactures 194 Cisco ASR 907 Router Hardware Installation Guide ix Contents ...

Страница 10: ...Cisco ASR 907 Router Hardware Installation Guide x Contents ...

Страница 11: ... key feature of the Cisco ASR 907 Router is to increase per platform and rack unit interface density especially when combining multiple interface types such as Gigabit Ethernet GE TDM 10GE 40GE and 100GE The Cisco ASR 907 Router has the following hardware features A larger service scale and higher throughput 400G Route Switch Processors RSP A900 RSP3C 400 W One port 100GE Interface Module A900 IMA...

Страница 12: ...Us except GPS module while the system is operational Power supply 1 1 Support for both AC and DC power supplies A single power supply can support full system load If there are two PSUs in the system they work in a load sharing mode Fully redundant system with redundant combined control plane and data plane excluding interfaces timing support power supplies and fans Active and standby support of re...

Страница 13: ...r Table 1 Cisco ASR 907 Router System Specifications 12 224 inches x 17 426 inches x 9 33 inches Dimensions Height x Width x Depth 12 224 inches x 17 426 inches x 10 705 inches The additional depth is due to the projection of the handle from Chassis face Note Dimensions with FRUs Weight 15 868 kg Chassis with back plane 3 618 kg Fan tray 0 924 kg 1200W DC PSU 1 0 kg 1200W AC PSU 2 46 kg RSP A900 R...

Страница 14: ...uggable module that allows direct interface with the external antenna Using a single GPS antenna input for both RSPs requires usage of external splitters Note To reduce the risk of fire use only No 26 AWG or larger telecommunication line cord Statement 1023 Warning The GNSS module is not hot swappable Note GNSS Module RF Input Requirements The GNSS module requires an active GPS GNSS antenna with b...

Страница 15: ...rthed at the building entrance in accordance with the ANSI NFPA 70 the National Electrical Code NEC in particular Section 820 93 Grounding of Outer Conductive Shield of a Coaxial Cable Note Use a passive splitter if more than one GNSS modules are fed from a single antenna Power Supply Features The Cisco ASR 907 Router supports 1200W DC AC power supplies on all the three PSU slots The AC and DC pow...

Страница 16: ...ls or input power on one line fails Redundancy is supported either with identical power supplies or a combination of AC and DC power supply The Cisco ASR 907 Router supports current sharing between the power supplies If you install a redundant power supply on the Cisco ASR 907 Router we recommend that you connect each power supply to a separate input power source in order to ensure that the router...

Страница 17: ...hen the air plenum and the fan filter are installed in the chassis the system operating temperature is 55º C Note RSP Modules The Cisco ASR 907 Router is designed to use up to two RSP modules to handle the data plane network timing and control plane functionalities for the router The RSP configuration allows you to use Cisco IOS software to control chassis management redundancy external management...

Страница 18: ...upplies Field replacement and hot swap capabilities Swapping of Interface Modules The following Ethernet interface modules support swapping on the Cisco A900 RSP3C 400 W module 8 port Gigabit Ethernet SFP Interface Module 8X1GE 8 port Gigabit Ethernet RJ45 Copper Interface Module 8X1GE SFP Combo IM 8 port Gigabit Ethernet 8X1GE 1 port 10 Gigabit Ethernet 1X10GE Copper Combo IM 8 port Gigabit Ether...

Страница 19: ... For more information see Cisco IOS Interface and Hardware Component Command Reference If the module does not come up perform a reload of the router Supported Interface Modules There are certain restrictions in using the interface modules on different slots in the chassis Contact Cisco Sales and Support for the valid combinations Note Cisco ASR 907 Router Hardware Installation Guide 9 Cisco ASR 90...

Страница 20: ...d A900 IMASER14A S 14 port Serial Interface Module Not Supported A900 IMA8D 8 port T1 E1 Interface Module Not Supported A900 IMA32D 32 port T1 E1 Interface Module 7 and 8 A900 IMA1C 1x100G Interface module 7 and 81 A900 IMA2C 2 port 100 Gigabit Ethernet QSFP Interface Module 2X100GE 3 4 7 8 11 12 A900 IMA2F 2x40G Interface module 3 4 7 8 11 12 A900 IMA8Z2 8x10G Interface module 0 1 2 3 4 5 6 7 8 9...

Страница 21: ...Combo 8 Port SFP GE and 1 Port 10GE With CEM iMSG 20G Interface Module 1 IM supports only one port of 100G with RSP3 as QSFP28 on Port 0 in both slots 7 and 8 2 Six IM slots are supported with various combinations but only five IM slots are functional at a time 3 These slots are supported on 10G or 20G mode 4 These slots are supported on 10G or 20G mode only if the adjacent odd slots are empty 5 T...

Страница 22: ...A8CS1Z M 8 port SFP 8 port CSFP Gigabit Ethernet 8 16X1GE 1 port 10 Gigabit Ethernet 1X10GE Interface module 4 5 7 9 10 and 11 A900 IMA8Z 8x10G Interface module RSP Redundancy The Cisco ASR 907 Router chassis includes two RSP slots to allow for redundant RSPs When the router uses redundant RSPs one RSP operates in the active mode and the other operates in the hot standby mode Removal or failure of...

Страница 23: ...ry port 7 Ethernet management port 8 BITS timing port 9 Interface Modules The network interfaces are provided through pluggable interface modules The following list describes the various IM port density GE SFP ports Supports 100 1000 modes GE Copper RJ45 ports Supports 10 100 1000 operation 10GE SFP or XFP ports Supports 10G mode in Phase2 IMs 10GE port on Phase2 IMs Supports LAN WAN OTU1e 2 2e mo...

Страница 24: ... OC3 OC12 OC48 OC192 Supports TDM channelized PWE3 Processing For information about supported interface modules see the data sheet for the Cisco ASR 900 Series Aggregation Services Routers Note For more information about installing see the Installing an Interface Module 8 Port 1 Gigabit Ethernet SFP Interface Module A900 IMA8S The Gigabit Ethernet Small Form Factor Pluggable SFP interface module p...

Страница 25: ...n supported SFP modules see Cisco ASR 900 Series Aggregation Services Routers Data Sheet 1 Port 10 Gigabit Ethernet XFP Interface Module A900 IMA1X The 10 Port Gigabit Ethernet XFP interface module provides a single port supporting a 10 Gigabit Ethernet XFP module The figure below shows the interface module Figure 5 1 port 10 Gigabit Ethernet XFP Interface Module 1 port 10 Gigabit Ethernet interfa...

Страница 26: ... Use the hw module subslot command to enable the interface module in slot 0 of the router Save the configuration and reload the router to activate the interface module To remove the configuration use no hw module subslot command For information on supported SFP modules see Cisco ASR 900 Series Aggregation Services Routers Data Sheet 8 Port 1 Gigabit Ethernet SFP with 1 Port 10 Gigabit Ethernet Com...

Страница 27: ...odule A900 IMA8T1Z This 8 port 1 Gigabit Ethernet RJ45 Copper interface module with the 1 port 10 Gigabit Ethernet interface module is a high density combination interface module This module supports 8 Gigabit Ethernet Copper ports and 1 10 Gigabit Ethernet SFP port Cisco ASR 907 Router Hardware Installation Guide 17 Cisco ASR 907 Router Overview 8 Port 1 Gigabit Ethernet 1 Port 10 Gigabit Etherne...

Страница 28: ...rovides a dual port supporting a 10 Gigabit Ethernet SFP and XFP module Figure 9 2 port10 Gigabit Ethernet Interface Module For information on supported SFP modules see Cisco ASR 900 Series Aggregation Services Routers Data Sheet Cisco ASR 907 Router Hardware Installation Guide 18 Cisco ASR 907 Router Overview 2 Port 10 Gigabit Ethernet SFP Interface Module A900 IMA2Z ...

Страница 29: ... 2X100GE N560 IMA2C The 2 port 100 Gigabit Ethernet Interface Module N560 IMA2C design supports only one 100G QSFP28 optics on Port 0 Port 1 is disabled with RSP3 It currently supports only one mode of operation with 100Gbps of traffic with RSP3 Figure 11 2 Port 100 Gigabit Ethernet Interface Module 2X100GE For information on supported QSFP modules see Cisco ASR 900 Series Interface Modules Data S...

Страница 30: ...ing QSFP optics The figure below shows the interface module Figure 12 2 port 40 Gigabit Ethernet Interface Module For information on supported SFP modules see Cisco ASR 900 Series Aggregation Services Routers Data Sheet 8 16 Port1GigabitEthernet SFP SFP 1 port10GigabitEthernet SFP 2 port1GigabitEthernet CSFP Interface Module A900 IMA8CS1Z M The A900 IMA8CS1Z M interface module has the flexibility ...

Страница 31: ...Sheet For more information on port numbering see Configuring 1 port 10 Gigabit Ethernet 1 X SFP 1 port Gigabit Ethernet 1 X SFP 2 port Gigabit Ethernet 1 X CSFP and 16 port Gigabit Ethernet 8 X CSFP 8 port Gigabit Ethernet 8 X SFP Interface Module chapter of the Cisco ASR 900 Router Series Configuration Guide Cisco IOS XE Everest 16 6 1 16 Port T1 E1 Interface Module A900 IMA16D The 16 port T1 E1 ...

Страница 32: ... Tyco connectors It is supported on the A900 RSP2A 64 module in slots 3 4 and 5 and on the A900 RSP2A 128 on all slots The 32 port T1 E1 interface module requires the use of a patch panel to provide RJ48 or BNC connectors Figure 15 32 portT1 E1 Interface Module Cisco ASR 907 Router Hardware Installation Guide 22 Cisco ASR 907 Router Overview 32 Port T1 E1 Interface Module A900 IMA32D ...

Страница 33: ...ts see Supported RSPs Figure 16 8 portT1 E1 Interface Module 48 Port T1 E1 CEM Interface Module A900 IMA48D C The 48 port T1 E1 interface module provides connectivity for up to 48 T1 E1 ports through 3 high density connectors on the front panel as shown in figure 48 port T1 E1 Faceplate Each port supports 16 TX and RX ports Cisco ASR 907 Router Hardware Installation Guide 23 Cisco ASR 907 Router O...

Страница 34: ...provides connectivity for up to 48 T3 E3 ports through 3 high density connectors on the front panel see the figure below Each port supports 16 TX and RX ports Figure 19 48 x T3 E3 Interface Module Figure 20 48 port T3 E3 Faceplate Cisco ASR 907 Router Hardware Installation Guide 24 Cisco ASR 907 Router Overview 48 Port T3 E3 CEM Interface Module A900 IMA48T C ...

Страница 35: ...Module For information on supported SFP modules see Cisco ASR 900 Series Aggregation Services Routers Data Sheet 1 Port OC 192 or 8 Port Low Rate CEM Interface Module 10G HO 10G LO A900 IMA8S1Z CX The 1 port OC 192 interface module with 8 port low rate CEM interface module is a high density combination interface module This module supports 1 OC 192 port or 8 low rate CEM or 1 Gigabit Ethernet port...

Страница 36: ... table given in Port Combinations Usage Guidelines section Each SFP port can be configured for SONET or Ethernet SFP ports configuration parameter see the table given in Port Combinations Usage Guidelines section Maximum of 4 x OC 48 interfaces are supported per interface module For each OC 48 port enabled neighboring SFP ports cannot be configured OC 3 and OC 12 port configuration is supported on...

Страница 37: ...es see Cisco ASR 900 Series Aggregation Services Routers Data Sheet ASR 900 Combo 8 Port SFP GE and 1 Port 10GE With CEM iMSG 20G Interface Module A900 IMA1Z8S CXMS The ASR 900 Combo 8 Port SFP GE and 1 Port 10GE With CEM iMSG 20G Interface Module is a cost effective interface module IM that supports CEM and Multiservice Gateway features on the OCn interfaces The Multiservice Gateway features are ...

Страница 38: ... more flexibility from the interface which allows you to configure any interface speed on the OCn port irrespective of the IM bandwidth The bandwidth restriction comes into effect only when the circuit is configured For example you can configure the SFP port as an OC 192 and the other eight optical ports as OC 48 to have the total interface speed of 30G However if you configure only one STS 1 HO C...

Страница 39: ...1 and so on Following is the A900 RSP4 port numbering For IM N560 IMA2C the port numbering is HundredGigE 0 0 0 0 0 0 0 1 For IM A900 IMA8Z the port numbering is TenGigE 0 0 0 1 0 0 0 7 For IM A900 IMA8CS1Z M the port numbering is GigE 0 0 0 0 0 0 0 15 TenGigE 0 0 06 16 The following commands display the active RP slot number The interface module is referenced as 1 x instead of 0 x show diag all e...

Страница 40: ...Cisco ASR 907 Router Hardware Installation Guide 30 Cisco ASR 907 Router Overview Regulatory Compliance ...

Страница 41: ...fer to the Regulatory Compliance and Safety Information document that accompanied this device To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety This unit should be mounted at the bottom of the rack if it is the only unit in the rack When mount...

Страница 42: ... that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device Statement 1071 Warning This is a Class A Device and is regist...

Страница 43: ...ulatory Compliance and Safety Information document that accompanied this device Hazardous network voltages are present in WAN ports regardless of whether power to the unit is OFF or ON To avoid electric shock use caution when working near WAN ports When detaching cables detach the end away from the unit first Statement 1026 Warning Blank faceplates and cover panels serve three important functions ...

Страница 44: ...to power and ground and can cause serious burns or weld the metal object to the terminals Statement 43 Warning Do not work on the system or connect or disconnect cables during periods of lightning activity Statement 1001 Warning Before performing any of the following procedures ensure that power is removed from the DC circuit Statement 1003 Warning Read the installation instructions before connect...

Страница 45: ...58 Warning Take care when connecting units to the supply circuit so that wiring is not overloaded Statement 1018 Warning The plug socket combination must be accessible at all times because it serves as the main disconnecting device Statement 1019 Warning To avoid electric shock do not connect safety extra low voltage SELV circuits to telephone network voltage TNV circuits LAN ports contain SELV ci...

Страница 46: ...t the telephone network cables to avoid contact with telephone network voltages Statement 1041 Warning This equipment must be installed and maintained by service personnel as defined by AS NZS 3260 Incorrectly connecting this equipment to a general purpose outlet could be hazardous The telecommunications lines must be disconnected 1 before unplugging the main power connector or 2 while the housing...

Страница 47: ...y follow these guidelines Locate the room s emergency power off switch If an electrical accident occurs you will be able to quickly turn off the power Before working on the system turn off the DC main circuit breaker and disconnect the power terminal block cable Before doing the following disconnect all power Working on or near power supplies Installing or removing a router chassis or network proc...

Страница 48: ...ly to ground connect the clip to an unpainted surface of the chassis frame To guard against ESD damage and shocks the wrist strap and cord must operate effectively If no wrist strap is available ground yourself by touching a metal part of the chassis When installing a component use any available ejector levers or captive installation screws to properly seat the bus connectors in the backplane or m...

Страница 49: ...this chapter The site meets the environmental requirements The site s air conditioning system can compensate for the heat dissipation of the Cisco ASR 907 Router The floor space that the Cisco ASR 907 Router occupies can support the weight of the system Electrical service to the site complies with the requirements The electrical circuit servicing the Cisco ASR 907 Router complies with the requirem...

Страница 50: ...level of protection we recommend that the unit be installed in a fully sealed enclosure or cabinet Examples of such cabinets include IP65 cabinets with heat exchanger complying with Telecordia GR487 Temperature must be maintained within 40ºC to 65ºC Physical Characteristics Be familiar with the physical characteristics of the Cisco ASR 907 Router to assist you in placing the system in the proper l...

Страница 51: ...ir Flow To ensure adequate airflow it is recommended that you maintain a minimum clearance distance always as mentioned in the following figure Cisco ASR 907 Router Hardware Installation Guide 41 Preparing for Installation Air Flow Guidelines ...

Страница 52: ...Figure 26 Front View of Cisco A907 F2B AIR Clearance Cisco ASR 907 Router Hardware Installation Guide 42 Preparing for Installation Air Flow Guidelines ...

Страница 53: ... can occur within the rack and the routers that occupy it The site should also be as dust free as possible Dust tends to clog the router fans reducing the flow of cooling air through the equipment rack and the routers that occupy it thus increasing the risk of an overtemperature condition Enclosed racks must have adequate ventilation Ensure that the rack is not congested because each router genera...

Страница 54: ...lines The Cisco ASR 907 Router has specific power and electrical wiring requirements Adhering to these requirements ensures reliable operation of the system Follow these precautions and recommendations when planning your site power for the Cisco ASR 907 Router The redundant power option provides a second identical power supply to ensure that power to the chassis continues uninterrupted if one powe...

Страница 55: ...P3 400 standby 17 5 W A900 IMA8T 8 port 1 GE RJ45 interface module 17 5 W A900 IMA8S 8 port 1 GE SFP interface module 14 5 W A900 IMA8D 8 port T1 E1 interface module 14 5 W A900 IMA16D 16 port T1 E1 interface module 18 W A900 IMA32D 32 port T1 E1 interface module 29 W A900 IMA8S1Z 8 port 1GE SFP 1 port 10 GE interface module 27 W A900 IMA8T1Z 8 port 1GE RJ 45 Copper 1 10 GE interface module 57 W A...

Страница 56: ...The T1 E1 interface module for the Cisco ASR 907 Router uses a high density connector that requires the use of a T1 E1 interface cable and a customer provided patch panel For more information see Connecting T1 E1 Cables Shielded cables must be used to connect to the RJ 45 alarm connector on the fan tray in order to comply with FCC EN55022 CISPR22 Class A emissions requirements For information abou...

Страница 57: ...cal surge suppression For information about the electrode magnetic compliance standards supported on the Cisco ASR 907 Router see Regulatory Compliance and Safety Information for the Cisco ASR 907 Router Radio Frequency Interference When electromagnetic fields act over a long distance radio frequency interference RFI may be propagated Building wiring can often act as an antenna receiving the RFI s...

Страница 58: ...ware included with the chassis is suitable for most 19 inch equipment racks Consider installing the Cisco ASR 907 Router in a rack with the following features Network Equipment Building System NEBS compliant 19 inch 48 3 cm wide rack EIA or European Telecommunications Standards Institute ETSI hole patterns in the mounting rails The required mounting hardware is shipped with the Cisco ASR 907 Route...

Страница 59: ...larly to check the internal system status The environmental monitor continually checks the interior chassis environment it provides warnings about high temperature and creates reports on other potentially dangerous occurrences If warning messages are displayed take immediate action to identify the cause and correct the problem Keep the Cisco ASR 907 Router off the floor and out of areas that colle...

Страница 60: ...devices connected System power turned on System boot complete STATUS LED is on Shared port adapters are operational Correct software configuration displayed after system banner appears Creating a Site Log The Site Log provides a record of all the actions related to installing and maintaining the router Keep it in an accessible place near the chassis so that anyone who performs tasks has access to ...

Страница 61: ...5 Chassis Lifting Guidelines The chassis is not intended to be moved frequently Before you install the system ensure that your site is properly prepared so that you can avoid having to move the chassis later to accommodate power sources and network connections Cisco ASR 907 Router Hardware Installation Guide 51 Preparing for Installation Chassis Lifting Guidelines ...

Страница 62: ...ber 1 and Number 2 Phillips head screwdrivers Flat blade screwdrivers Small 3 16 inch 0 476 cm and medium 1 4 inch 0 625 cm To install or remove modules To remove the cover if you are upgrading the memory or other components 12 24 pan head screws to secure the router to the equipment rack Cables for connecting to the WAN and LAN ports depending on the configuration For more information on cable sp...

Страница 63: ...will need the container if you move or ship the Cisco ASR 907 Router in the future Table 7 Cisco ASR 907 Router Shipping Container Contents Description Component Cisco ASR 907 Router chassis Chassis Fan tray Power supplies RSP Interface modules Chassis rack mount brackets 19 inch EIA Accessories kit Three sets of screws Front and rear rack mount bracket screws 2 sets Cable management bracket screw...

Страница 64: ...line Documentation that is shipped with your Cisco ASR 907 Router includes the Regulatory Compliance and Safety Information for the Cisco ASR 900 Series Aggregation Service Router document and the Cisco ASR 900 Series Aggregation Service Router Documentation Roadmap that contains information about the various documents that are available online and the links to them Note Cisco ASR 907 Router Hardw...

Страница 65: ...it is important to prepare for the installation by Preparing the site site planning and reviewing the installation plans or method of procedures MOP Unpacking and inspecting the Cisco ASR 907 Router Gathering the tools and test equipment required to properly install the Cisco ASR 907 Router For more instructions on how to prepare for the installation of the Cisco ASR 907 Router see Preparing for I...

Страница 66: ...lter A907 FAN F cannot be mounted using the mounting screws that are supported for fan tray This is not an issue with the FAN tray filter blank panel A907 FAN F B We recommend that you use the short screws provided in the following rack mount kits to avoid interference of the air filter during rack mounting and while replacing the fan tray with the fan tray filter A907 FAN E 19 rack mount kit A907...

Страница 67: ...ween the mounting posts Step 2 Align the mounting holes in the bracket and optional cable guide with the mounting holes in the equipment rack Do not use interface module and power supply ejector handles to lift the chassis using the handles to lift the chassis can deform or damage the handles Installing the Chassis to support the Japanese JIS Rack Standard Caution Figure 30 Installing the Chassis ...

Страница 68: ...igure 31 Installing the Chassis to support the Japanese JIS Rack Standard Cisco ASR 907 Router Hardware Installation Guide 58 Installing the Cisco ASR 907 Router Installing the Router Chassis in the Rack ...

Страница 69: ...2 24 x 3 4 inch or 10 32 x 3 4 inch screws through the holes in the bracket and into the threaded holes in the equipment rack posts Step 4 Use a tape measure and level to verify that the chassis is installed straight and level Installing Plenum A907 F2B AIR U Assembly and Chassis in the Rack Procedure Step 1 Position the air baffle and the side plate to the plenum Secure the air baffle using a max...

Страница 70: ...cable brackets to the rack using a torque of 11 5 in lb 1 3 N m See figure below For a 19 inch rack installation the rack has to have a flat post Note Cisco ASR 907 Router Hardware Installation Guide 60 Installing the Cisco ASR 907 Router Installing Plenum A907 F2B AIR U Assembly and Chassis in the Rack ...

Страница 71: ...peat Step 1 and Step 2 to complete the plenum assembly on the other side of the plenum base Cisco ASR 907 Router Hardware Installation Guide 61 Installing the Cisco ASR 907 Router Installing Plenum A907 F2B AIR U Assembly and Chassis in the Rack ...

Страница 72: ...ferent Adapters Figure 36 Plenum Installation on Various Racks Step 6 Position the plenum assembly to the rack and secure the cable brackets to the rack using a torque of 11 5 in lb 1 3 N m See figure below For a 19 inch rack installation the rack has to have a flat post Note Cisco ASR 907 Router Hardware Installation Guide 62 Installing the Cisco ASR 907 Router Installing Plenum A907 F2B AIR U As...

Страница 73: ...Figure 37 Plenum Assembly to 21 inch Rack Cisco ASR 907 Router Hardware Installation Guide 63 Installing the Cisco ASR 907 Router Installing Plenum A907 F2B AIR U Assembly and Chassis in the Rack ...

Страница 74: ...ing the air plenum on the rack Procedure Step 1 Position the chassis so that the rear of the chassis is at the front of the plenum See the figure below Step 2 Slide the chassis into the plenum so that the front of the chassis is in flush with the mounting rails and brackets Cisco ASR 907 Router Hardware Installation Guide 64 Installing the Cisco ASR 907 Router Installing the Chassis in the Air Ple...

Страница 75: ... The mounting brackets and cable mounting brackets are assembled together We recommend that the brackets are installed before the chassis is installed in the Air Plenum Note To install the optional cable management brackets perform these steps Procedure Step 1 Position the cable management brackets against the front of the chassis and align the four screw holes as shown in the figure below Cisco A...

Страница 76: ...or turn on the power to the Cisco ASR 907 Router you must provide an adequate chassis ground earth connection to your router This section describes how to ground the Cisco ASR 907 Router chassis The router provides two locations for attaching a 2 hole grounding lug according to the rack mounting brackets you use to install the router Cisco ASR 907 Router Hardware Installation Guide 66 Installing t...

Страница 77: ...opriate to the wire you are using Before making connections to the Cisco ASR 907 Router ensure that you disconnect the power at the circuit breaker Otherwise severe injury to you or damage to the router may occur Caution This equipment must be grounded Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electric...

Страница 78: ...ol to strip the ground wire to 0 5 inch 0 02 inch 12 7 mm 0 5 mm As shown in the figure below Figure 42 Stripping a Ground Wire Step 2 Slide the open end of your 2 hole ground lug over the exposed area of the ground wire Step 3 Using a crimping tool as specified by the ground lug manufacturer crimp the ground lug to the ground wire as shown in figure below Figure 43 Crimping a Ground Lug onto the ...

Страница 79: ...stall the fan tray in the chassis Procedure Step 1 Orient the fan tray so that the captive screws are on the left side of the fan tray s front panel The figure below shows how to orient the fan tray Figure 44 Installing the Fan Tray Step 2 Guide the fan tray into the chassis until it is fully seated The fans are exposed on the left side of the fan tray Keep your fingers clothing and jewelry away f...

Страница 80: ...html For information about connecting cables to the fan tray alarm port see Connecting the Fan Tray Alarm Port For a summary of the LEDs on the fan tray see LED Summary For more information about air flow guidelines see Air Flow Guidelines Removing and Replacing the Dust Filter The chassis is shipped with a blank fan filter cover To install the dust filter Procedure Step 1 Remove the blank fan fil...

Страница 81: ...ironment Surroundings that adversely affect the dust filter are high heat humidity at high temperatures and ultraviolet light Note Dust Filter Maintenance A periodic health check of the filter every 3 months based on the level of dust in the environment helps in avoiding over clogging of the filters and provides a better life This product s filter is used as a single use component If the product i...

Страница 82: ...y parts or objects in the fan tray slot when installing or removing the fan tray module Exposed circuitry is an energy hazard Note The router can stay active for up to 60 seconds if the temperature is up to 30º C However in the event of an overtemperature alarm the router can shut down in less than 60 seconds In the event of a critical temperature alarm the router shuts down immediately Caution To...

Страница 83: ...ndle The fans are exposed on the left side of the fan tray Keep your fingers clothing and jewelry away from the fans Always handle the fan tray by the handle Caution Step 3 Pull the fan tray toward you no more than 1 inch to disengage it from the power receptacle on the midplane as shown in the figure below Cisco ASR 907 Router Hardware Installation Guide 73 Installing the Cisco ASR 907 Router Rem...

Страница 84: ...an tray with one hand and keep your other hand on the fan tray handle Note This completes the steps for removing the fan tray from the chassis The chassis must not be allowed to operate without functioning fans for more than 60 seconds Note To install the new fan tray follow the steps in Installing the Fan Tray RSP Installation Follow these steps on handling an RSP module in the Cisco ASR 907 Rout...

Страница 85: ...ond RSP module in the slot below it be careful not to damage the EMI gasket of the bottom RSP module against the ejector levers of the top RSP during insertion Caution Step 5 While pressing down simultaneously close both the ejector levers to fully seat the module in the backplane connector The ejector levers are fully closed when they are flush with the module faceplate Step 6 Tighten the two cap...

Страница 86: ...ble laser radiation may be emitted from disconnected fibers or connectors Do not stare into beams or view directly with optical instruments Statement 1051 Warning To remove an RSP module perform the following steps Procedure Step 1 Disconnect any cables attached to the ports on the module Step 2 Verify that the captive installation screws on all the modules in the chassis are tight This step ensur...

Страница 87: ...if there is sufficient power for the module 2 Scans the backplane for configuration changes 3 Initializes the newly inserted module In addition the system notes any removed modules and places those modules in the administratively shutdown state 4 Places any previously configured interfaces on the module back to the state they were in when they were removed Any newly inserted interfaces are put in ...

Страница 88: ...ges of the IM carrier between the upper and lower edges of the router slot Step 3 Carefully slide the IM carrier into the router slot until the IM carrier makes contact with the backplane See the figure below Figure 50 Installing the IM Carrier Interface Module Installation The following sections describe the various tasks of associated with interface module installation on the Cisco ASR 907 Route...

Страница 89: ... Step 4 ITighten the locking thumbscrews on both sides of the interface module The recommended maximum torque is 5 5 in lb 62 N m Step 5 Connect all the cables to each interface module What to do next Do not use interface module and power supply ejector handles to lift the chassis using the handles to lift the chassis can deform or damage the handles Caution Close all unused RJ 45 SFP XFP and QSFP...

Страница 90: ... Cisco ASR 907 Router does not support hot swapping an interface module with another module of a different type For example you cannot swap an SFP Gigabit Ethernet module with a copper Gigabit Ethernet module without disrupting router operation Note If the TDM interface module is swapped with the Gigabit Ethernet module in the same slot or vice versa the router must be reloaded Note If you perform...

Страница 91: ... QSFP Interface Module 2X40GE 8 16 port 1 Gigabit Ethernet SFP SFP 1 port 10 Gigabit Ethernet SFP 2 port 1 Gigabit Ethernet CSFP Interface Module 1 port OC48 STM 16 or 4 port OC 12 OC 3 STM 1 STM 4 12 Port T1 E1 4 Port T3 E3 CEM Interface Module No support 16 x T1 E1 Interface Module 32 x T1 E1 Interface Module 8 X T1 E1 Interface Module 1 Port OC 192 or 8 Port Low Rate CEM Interface Module 48 x T...

Страница 92: ...ply The Cisco ASR 907 Router router provides the choice of two different power supplies 1200 W DC power 40 8VDC to 72VDC The DC power supply uses 3 position terminal block style connector with positive latching securing and labeled connections for 48V GRD 48V The terminal block connector is of suitable size to carry the appropriate AWG wire size to handle the input current of the power supply No O...

Страница 93: ...wer Supply Specifications table to estimate the power requirements and heat dissipation of a Cisco ASR 907 Router based on a given configuration of the router Determining power requirements is useful for planning the power distribution system needed to support the router Power Connection Guidelines This section provides guidelines for connecting the Cisco ASR 907 Router power supplies to the site ...

Страница 94: ...chassis power supply should have its own dedicated branch circuit The circuit breaker should be sized according to the power supply input rating and local or national code requirements The AC power receptacles used to plug in the chassis must be the grounding type The grounding conductors that connect to the receptacles should connect to protective earth ground at the service equipment Installing ...

Страница 95: ...ur other hand underneath the power supply as shown in the figure below Slide the power supply into the power supply bay Make sure that the power supply is fully seated in the bay Figure 52 Installing the DC Power Supply Step 5 Tighten the captive installation screws of the power supply The recommended maximum torque is 5 5 in lb 62 N m If you are installing a redundant DC power supply repeat these...

Страница 96: ...a wire stripping tool to strip the ends of each of the two wires coming from the DC input power source as recommended by the lug manufacturer Stripping more than the recommended amount of wire can leave behind exposed wire from the terminal block after installation Note Step 4 Identify the positive and negative feed positions for the terminal block The recommended wiring sequence is as in the figu...

Страница 97: ...lows for some slack in the wire Activating the DC Power Supply Perform the following procedure to activate the DC power supply Procedure Step 1 Remove the tape from the circuit breaker switch handle and restore power by moving the circuit breaker switch handle to the On position Step 2 Verify power supply operation by checking if the power supply front panel LEDs are in the following states INPUT ...

Страница 98: ...y has been removed or replaced Caution When you install the unit the ground connection must always be made first and disconnected last Statement 1046 Warning Before performing any of the following procedures ensure that power is removed from the DC circuit Statement 1003 Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Statement 1030 Warni...

Страница 99: ... of the building installation Install only in accordance with national and local wiring regulations Warning Installing the AC Power Supply Module for A900 PWR1200 A 1200 W Follow these steps to install the power supply module Procedure Step 1 Ensure that the system earth ground connection has been made For ground connection installation instructions see theInstalling the Chassis Ground Connection ...

Страница 100: ...rotective grounding continuity Warning Recommended Power Cables We recommend the following power cables for Cisco ASR 907 routers Table 9 Power Cable PIDs for A900 PWR1200 A 1200 W Description PID US AC Power Cord for Cisco ASR 900 NEMA 5 20 PWR CAB AC USA520 Power Cord for AC V2 Power Module USA NEMA L6 20P PWR CAB AC USA Cisco ASR 907 Router Hardware Installation Guide 90 Installing the Cisco AS...

Страница 101: ...250 0 V 16 0 A PWR CAB AC ARG Activating the AC Power Supply Follow these steps to activate the AC power supply Procedure Step 1 Plug the power cord into the power supply Step 2 Connect the other end of the power cord to an AC input power source Step 3 Verify power supply operation by checking that the power supply LEDs are in the following states INPUT OK LED is green OUTPUT FAIL LED is green Ste...

Страница 102: ...arning Follow these steps to remove and replace the AC power supply Procedure Step 1 Disconnect the power cord from the power source Do not touch the metal prongs on the power cord when it is still connected to the power supply Step 2 Remove the power cord from the power connection on the power supply Do not touch the metal prongs embedded in the power supply Step 3 Loosen the captive installation...

Страница 103: ...r the RS232 port is disabled Note Connecting to the Serial Port using Microsoft Windows This procedure shows how to connect to the serial port using Microsoft Windows Install the USB device driver before establishing a physical connection between the router and the PC by using the USB Console cable plugged into the USB serial port Otherwise the connection will fail For more information see the Ins...

Страница 104: ...he DB 9 connector or USB Type A to the terminal or PC If your terminal or PC has a console port that does not accommodate a DB 9 connector you must provide an appropriate adapter for that port Step 3 To communicate with the router start a terminal emulator application such as Microsoft Windows HyperTerminal This software should be configured with the following parameters 9600 baud 8 data bits no p...

Страница 105: ...co ASR 907 Router USB 5 pin mini USB Type B to USB Type A console cable 2 USB Type A console port 1 USB Type A 3 Cisco ASR 907 Router Hardware Installation Guide 95 Installing the Cisco ASR 907 Router Connecting to the Serial Port using Microsoft Windows ...

Страница 106: ...em1a21 9600 To disconnect the OS X USB console from the Terminal window enter Ctrl a followed by Ctrl Connecting to the Console Port using Linux This procedure shows how to connect a Linux system USB port to the console using the built in Linux Terminal utility Procedure Step 1 Open the Linux Terminal window Step 2 Connect the Linux USB port to the router Step 3 Enter the following commands to fin...

Страница 107: ...tall Step 5 The InstallShield Wizard Completed window appears Click Finish Step 6 Connect the USB cable to the PC and router USB console ports The EN LED for the USB console port turns green and within a few moments the Found New Hardware Wizard appears Follow the instructions to complete the installation of the driver The USB console is ready for use Installing the Cisco Microsoft Windows 2000 US...

Страница 108: ...pop up window stating Installing device driver software appears Following the instructions to complete the installation of the driver Step 7 The USB console is ready for use Uninstalling the Cisco Microsoft Windows USB Driver This section provides instructions for how to uninstall the Cisco Microsoft Windows USB device driver Uninstalling the Cisco Microsoft Windows XP and 2000 USB Driver Using th...

Страница 109: ...k Next Step 3 When the Program Maintenance window appears select the Remove radio button Click Next Step 4 When the Remove the Program window appears click Remove If a User Account Control warning appears click Allow I trust this program to proceed Note Step 5 When the InstallShield Wizard Completed window appears click Finish Connecting to the Auxiliary Port When a modem is connected to the auxil...

Страница 110: ...p 3 Connect the DB 25 end of the modem adapter to the modem Step 4 Make sure that your modem and the router auxiliary port are configured for the same transmission speed up to 115200 bps is supported and for mode control with data carrier detect DCD and data terminal ready DTR operations Cisco ASR 907 Router Hardware Installation Guide 100 Installing the Cisco ASR 907 Router Connecting to the Auxi...

Страница 111: ...addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring Warning Installing and Removing SFP and XFP Modules The Cisco ASR 907 Router supports a variety of SFP and XFP modules including optical and Ethernet modules For information on how to install and remove SFP and XFP modules see the documentation for the SFP or XFP module at ht...

Страница 112: ...tes the USB Flash memory installation procedure Connecting Timing Cables The following sections describe how to connect timing cables to the Cisco ASR 907 Router When installing the cabling to the RSPs we recommend that you leave a service loop of extra cabling sufficient to allow for fan tray removal Note Connecting Cables to the BITS Interface The following steps describe how to connect a cable ...

Страница 113: ...ace The following sections describe how to connect cables from the Cisco ASR 907 Router to a GPS unit for input or output timing of frequency A Y cable is required to connect to a primary and backup RSP in order to ensure that the router continues to transmit timing signals in the event of a network failure For a mini coax connection this Y cable can be part number CAB BNC 7INY 7 inch BNC Y cable ...

Страница 114: ... with the Telcordia GR 1089 NEBS standard for electromagnetic compatibility and safety connect the ToD ports only to intra building or unexposed wiring or cable The intrabuilding cable must be shielded and the shield must be grounded at both ends The intra building port s of the equipment or subassembly must not be metallically connected to interfaces that connect to the OSP or its wiring These in...

Страница 115: ...Installing the GNSS Module in the RSP Inserting the GNSS Module 2 Screw on the GNSS Module 1 Connecting Ethernet Cables The Cisco ASR 907 Router interface modules support RJ45 or SFP Ethernet ports For instructions on how to connect cables to Ethernet SFP ports see Connecting Cables to SFP Modules The RJ45 port supports standard straight through and crossover Category 5 unshielded twisted pair UTP...

Страница 116: ...nnect one end of the cable to the Gigabit Ethernet port on the router Step 3 Connect the other end to the BTS patch or demarcation panel at your site Connecting Cables to SFP Modules For information on connecting cables to Cisco optical and Ethernet SFP interfaces see http www cisco com en US partner products hw modules ps5455 prod_installation_guides_list html Connecting T1 E1 Cables The physical...

Страница 117: ...o secure the cable to the interface The other end of the cable has two 50 pin Telco connectors that attach to the rear of a 24 port RJ45 patch panel Both connectors are identical one is for Transmit TX and the other is for Receive RX The figure below shows how the cable is connected between the 16 x T1 E1 interface module and the patch panel Cisco ASR 907 Router Hardware Installation Guide 107 Ins...

Страница 118: ...ch cables Each patch cable has a 68 pin connectors that connects with each connector port on the front panel of the 32 x T1 E1 interface module Use the thumbscrews on either side of the connectors to secure the cable to the interface The other end of the cable has two 50 pin Telco connectors that attach to the rear of a 24 port RJ45 patch panel Both connectors are identical one is for Transmit TX ...

Страница 119: ...re attached to RJ45 connectors on the front of the 24 port patch panel Each RJ45 port accommodates an individual T1 subscriber line For the T1 E1 ports see the T1 E1 Port Pinouts RJ 48 section Connecting Cables to the Patch Panel If you are connecting two T1 E1 interfaces to each other you must cable both interfaces patch panels together using a T1 cross over cable or a T1 straight through cable U...

Страница 120: ...ation from the exposed OSP cabling The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring Warning Patch Panel Pinout Given below are the pinout information for the regular crossover and the straight through cable patch panel Table 10 Pinout Details Straight through Crossover Pin Transmit Tip Receive Tip 1 Transmit Ring Receiv...

Страница 121: ... inches cable length and 6 5 inches stub length even slot T1 E1 Cable M 1 16 port cable for TDM CEM Interface Module 42 inches cable length and 10 inches stub length even slot T1 E1 Cable L 3 CABLE 16TDM R1EL3 16 port cable for TDM CEM Interface Module 42 inches cable length and 7 5 inches stub length even slot T1 E1 Cable L 2 16 port cable for TDM CEM Interface Module 42 inches cable length and 6...

Страница 122: ... for TDM CEM Interface Module 42 inches cable length and 10 inches stub length odd slot T1 E1 Cable S 3 CABLE 16TDM R1OL1 3 x 16 port cables for TDM CEM Interface Module 62 inches cable length and 10 inches stub length odd slot T1 E1 Cable M 3 CABLE 16TDM R1OL2 3 x 16 port cables for TDM CEM Interface Module 78 inches cable length and 10 inches stub length odd slot T1 E1 Cable L 3 CABLE 16TDM R1OL...

Страница 123: ...Remove the larger M4 rack mount screws as indicated in the Rack Mount Screws figure below from both sides To secure the brackets follow the instructions in Step 3 Step 2 Remove the patch panel rack mount brackets from the accessory kit and position them beside the patch panel Step 3 Position the brackets against the patch panel sides and align with the screw holes Secure the rack mount bracket to ...

Страница 124: ...atch Panel Rear View with Brackets Step 4 Position the cable management guides against the mounting brackets on the patch panel see the figure below Cisco ASR 907 Router Hardware Installation Guide 114 Installing the Cisco ASR 907 Router Installing Patch Panel ...

Страница 125: ...s with the screws The recommended maximum torque is 28 in lb 3 16 N m Step 6 Position the patch panel with brackets and guide onto the rack and secure with screws provided The recommended maximum torque is 28 in lb 3 16 N m see the figure below Cisco ASR 907 Router Hardware Installation Guide 115 Installing the Cisco ASR 907 Router Installing Patch Panel ...

Страница 126: ...Figure 69 Patch Panel Front View with Brackets and Guides Installed on Rack Cisco ASR 907 Router Hardware Installation Guide 116 Installing the Cisco ASR 907 Router Installing Patch Panel ...

Страница 127: ...Guides Installed on Rack Install 3G Patch Panel You can choose to either set up the Cisco ASR 903 3G patch panel on a rack or wall mount it Cisco ASR 907 Router Hardware Installation Guide 117 Installing the Cisco ASR 907 Router Install 3G Patch Panel ...

Страница 128: ...round lug manufacturer crimp the ground lug to the ground wire Step 2 Use a 6 AWG ground wire to connect the other end to a suitable grounding point at your site Figure 71 Patch Panel Grounding Single Cisco ASR 907 Router Hardware Installation Guide 118 Installing the Cisco ASR 907 Router Install Rack Brackets ...

Страница 129: ...ar of the chassis between the mounting posts If the rear of the patch panel is at the front of the rack insert the front of the chassis between the mounting posts Step 4 Align the mounting holes in the bracket with the mounting holes in the equipment rack Cisco ASR 907 Router Hardware Installation Guide 119 Installing the Cisco ASR 907 Router Install Rack Brackets ...

Страница 130: ...Figure 73 Installing the Patch Panel Single in a 19 inch Rack Cisco ASR 907 Router Hardware Installation Guide 120 Installing the Cisco ASR 907 Router Install Rack Brackets ...

Страница 131: ...Figure 74 Installing the Patch Panel Dual in a 19 inch Rack Cisco ASR 907 Router Hardware Installation Guide 121 Installing the Cisco ASR 907 Router Install Rack Brackets ...

Страница 132: ...Figure 75 Installing the Patch Panel Single in a 21 inch Rack Cisco ASR 907 Router Hardware Installation Guide 122 Installing the Cisco ASR 907 Router Install Rack Brackets ...

Страница 133: ...Figure 76 Installing the Patch Panel Dual in a 21 inch Rack Cisco ASR 907 Router Hardware Installation Guide 123 Installing the Cisco ASR 907 Router Install Rack Brackets ...

Страница 134: ...Figure 77 Installing the Patch Panel Single in a 23 inch Rack Cisco ASR 907 Router Hardware Installation Guide 124 Installing the Cisco ASR 907 Router Install Rack Brackets ...

Страница 135: ...gle and double 3G interface module patch panels Set up 3G Patch Panel on Rack To install the optional cable management brackets perform these steps Procedure Step 1 Position the cable management brackets against the front of the chassis and align the screw holes as shown in the figure Step 2 Secure the cable management brackets with the screws The recommended maximum torque is 10 in lb 1 12 N m Ci...

Страница 136: ...Figure 79 Attaching 19 inch Brackets to Patch Panel Single Cisco ASR 907 Router Hardware Installation Guide 126 Installing the Cisco ASR 907 Router Set up 3G Patch Panel on Rack ...

Страница 137: ...Figure 80 Installing 19 inch Brackets on to Rack Single Cisco ASR 907 Router Hardware Installation Guide 127 Installing the Cisco ASR 907 Router Set up 3G Patch Panel on Rack ...

Страница 138: ...Figure 81 Attaching 19 inch Brackets to Patch Panel Dual Cisco ASR 907 Router Hardware Installation Guide 128 Installing the Cisco ASR 907 Router Set up 3G Patch Panel on Rack ...

Страница 139: ...Figure 82 Installing 19 inch Brackets on to Rack Dual Cisco ASR 907 Router Hardware Installation Guide 129 Installing the Cisco ASR 907 Router Set up 3G Patch Panel on Rack ...

Страница 140: ...Figure 83 Attaching 21 inch Brackets to Patch Panel Single Cisco ASR 907 Router Hardware Installation Guide 130 Installing the Cisco ASR 907 Router Set up 3G Patch Panel on Rack ...

Страница 141: ...Figure 84 Installing 21 inch Brackets on to Rack Single Cisco ASR 907 Router Hardware Installation Guide 131 Installing the Cisco ASR 907 Router Set up 3G Patch Panel on Rack ...

Страница 142: ...Figure 85 Attaching 21 inch Brackets to Patch Panel Dual Cisco ASR 907 Router Hardware Installation Guide 132 Installing the Cisco ASR 907 Router Set up 3G Patch Panel on Rack ...

Страница 143: ...Figure 86 Installing 21 inch Brackets on to Rack Dual Cisco ASR 907 Router Hardware Installation Guide 133 Installing the Cisco ASR 907 Router Set up 3G Patch Panel on Rack ...

Страница 144: ...Figure 87 Attaching 23 inch Brackets to Patch Panel Single Cisco ASR 907 Router Hardware Installation Guide 134 Installing the Cisco ASR 907 Router Set up 3G Patch Panel on Rack ...

Страница 145: ...Figure 88 Installing 23 inch Brackets on to Rack Single Cisco ASR 907 Router Hardware Installation Guide 135 Installing the Cisco ASR 907 Router Set up 3G Patch Panel on Rack ...

Страница 146: ...Figure 89 Attaching 23 inch Brackets to Patch Panel Dual Cisco ASR 907 Router Hardware Installation Guide 136 Installing the Cisco ASR 907 Router Set up 3G Patch Panel on Rack ...

Страница 147: ...ou must first install the mounting brackets and cable guides on to the patch panel before you mount it on the wall You can use the same rack mount brackets 700 113653 01 for wall mount Cisco ASR 907 Router Hardware Installation Guide 137 Installing the Cisco ASR 907 Router Wall Mount 3G Patch Panel ...

Страница 148: ...the accessory kit and position them beside the device You can install the brackets as shown in the figure Note Figure 91 Wall Mount Single Cisco ASR 907 Router Hardware Installation Guide 138 Installing the Cisco ASR 907 Router Wall Mount 3G Patch Panel ...

Страница 149: ...re mounting the device ensure that all unused holes at the sides of the device are protected with screws Caution Step 4 Use a tape measure and level to verify that the device is installed straight and on level Patch Panel Dimensions Following are the various patch panel dimensions Cisco ASR 907 Router Hardware Installation Guide 139 Installing the Cisco ASR 907 Router Patch Panel Dimensions ...

Страница 150: ...Figure 93 Patch Panel Without Brackets Cisco ASR 907 Router Hardware Installation Guide 140 Installing the Cisco ASR 907 Router Patch Panel Dimensions ...

Страница 151: ...Figure 94 Patch Panel With Brackets Cisco ASR 907 Router Hardware Installation Guide 141 Installing the Cisco ASR 907 Router Patch Panel Dimensions ...

Страница 152: ...Figure 95 AMP64 Patch Panel With Brackets Cisco ASR 907 Router Hardware Installation Guide 142 Installing the Cisco ASR 907 Router Patch Panel Dimensions ...

Страница 153: ...Figure 96 3G Patch Panel Without Brackets Single Cisco ASR 907 Router Hardware Installation Guide 143 Installing the Cisco ASR 907 Router Patch Panel Dimensions ...

Страница 154: ...TIA 232 connector Note Table 12 Interface Cables for 12 in 1 Connector Connector Male Female Length Product Number Cable Type M34 Male 10 ft CAB SS V35MT V 35 DTE M34 Female 10 ft CAB SS V35FC V 35 DCE DB 25 Male 10 ft CAB SS 232MT EIA TIA 232 DTE DB 25 Female 10 ft CAB SS 232FC EIA TIA 232 DCE DB 37 Male 10 ft CAB SS 449MT EIA TIA 449 DTE DB 37 Female 10 ft CAB SS 449FC EIA TIA 449 DCE DB 15 Male...

Страница 155: ...controlled through any appropriate third party relay controller The open close configuration is an option controlled in IOS To comply with the Telcordia GR 1089 NEBS standard for electromagnetic compatibility and safety connect the alarm ports only to intra building or unexposed wiring or cable The intrabuilding cable must be shielded and the shield must be grounded at both ends The intra building...

Страница 156: ...tical major and minor alarm conditions see the Cisco ASR 907 Router Software Configuration Guide Connector and Cable Specifications For more information on cable specifications and pinouts see Troubleshooting chapter Cisco ASR 907 Router Hardware Installation Guide 146 Installing the Cisco ASR 907 Router Connector and Cable Specifications ...

Страница 157: ...ecking Conditions Prior to System Startup Ensure that the following conditions are addressed before starting up the router The Route Switch Processor RSP is installed The optional Gigabit Ethernet Management port cable is installed The chassis is securely mounted and grounded The power and interface cables are connected Your PC with terminal emulation program hyperTerminal or equivalent is connect...

Страница 158: ...ys pressed during this time are interpreted as the first command typed when the messages stop which might cause the router to power off and start over It takes a few minutes for the messages to stop Caution This is only an example of what can display The system boots differently depending upon the configuration that ships with your system Note Step 2 Observe the initialization process When the sys...

Страница 159: ...mpanying the IOS XE software A summary of U S laws governing Cisco cryptographic products may be found at http www cisco com wwl export crypto tool stqrg html If you require further assistance please contact us by sending email to export cisco com cisco ASR907 processor with 541737K 6147K bytes of memory 4 Gigabit Ethernet interfaces 32768K bytes of non volatile configuration memory 1869396K bytes...

Страница 160: ...NEPROTO 5 UPDOWN Line protocol on Interface GigabitEthernet0 0 3 changed state to down Feb 19 17 35 19 167 ASR1000_OIR 6 REMSPA SPA removed from subslot 0 0 interfaces disabled Feb 19 17 35 19 171 ASR1000_OIR 6 INSCARD Card fp inserted in slot F0 Feb 19 17 35 19 171 ASR1000_OIR 6 ONLINECARD Card fp online in slot F0 Feb 19 17 35 19 187 ASR1000_OIR 6 INSCARD Card cc inserted in slot 0 Feb 19 17 35 ...

Страница 161: ...orted software needed for your hardware Configuring the Cisco ASR 907 Router at Startup This section explains how to create a basic running configuration for your Cisco ASR 907 Router You need to acquire the correct network addresses from your system administrator or consult your network plan to determine correct addresses before you can complete the router configuration Note Before continuing the...

Страница 162: ...e your desired tasks To exit the console session enter the quit command as shown in the following example Example Router quit Configuring Global Parameters When you first start the setup program you must configure the global parameters These parameters are used for controlling system wide settings Perform the following steps to enter the global parameters Procedure Step 1 Connect a console termina...

Страница 163: ...etup will ask you to configure each interface on the system For detailed information about setting global parameters refer to the Cisco ASR 907 Router Software Configuration Guide Checking the Running Configuration Settings To check the value of the settings you have entered enter the show running config command at the Router prompt Router show running config To review changes you make to the conf...

Страница 164: ... Cisco ASR 907 Router can be powered off safely To remove power from the Cisco ASR 907 Router safely follow this procedure and see the examples Procedure Step 1 Slip on the ESD preventive wrist strap that was included in the accessory kit Step 2 Enter the reload command Step 3 Confirm the reload command Example Router reload Proceed with reload confirm Sep 7 09 00 40 084 IST SYS 5 RELOAD Reload re...

Страница 165: ...n 1 Step 5 Remove any power cables from the Cisco ASR 907 Router a For power supplies with a circuit breaker switch position the switch to the Off O position b For power supplies with a Standby switch place the Standby switch in the Standby position Step 6 After powering off the router wait a minimum of 30 seconds before powering it on again Cisco ASR 907 Router Hardware Installation Guide 155 Cis...

Страница 166: ...Cisco ASR 907 Router Hardware Installation Guide 156 Cisco Router Initial Configuration Safely Powering Off the Cisco ASR 907 Router ...

Страница 167: ...or the Cisco ASR 907 Router interfaces BITS Port Pinout The table below summarizes the BITS port pinout of the Front Panel Building Integrated Timing Supply RJ48 port Table 14 BITS Port Pinout Description Direction Signal Name Pin Receive Ring Input RX Ring 1 Receive Tip Input RX Tip 2 Not used 3 TX Ring Output TX Ring 4 TX Tip Output TX Tip 5 Not used 6 Not used 7 Not used 8 Cisco ASR 907 Router ...

Страница 168: ...compatible Output 2 4 volts TTL compatible Input 1 7 volt p p 8 to 10 dBm Output 2 4 volts TTL compatible Amplitude 50 ohms 50 ohms Impedance 26 microseconds 50 duty cycle Pulse Width 40 nanoseconds Input AC coupled Output 5 nanoseconds Rise Time Time of Day Pinout The table below summarizes the ToD pinouts Table 16 ToD pinouts Description Direction Signal Name Pin Do Not Connect Output or Inputs ...

Страница 169: ...alarm input pinout Table 18 External Alarm Input Pinout Description Signal Name Pin Alarm input 0 ALARM0_IN 1 Alarm input 1 ALARM1_IN 2 No connect 3 Alarm input 2 ALARM2_IN 4 Alarm input 3 ALARM3_IN 5 No connect 6 No connect 7 Alarm common COMMON 8 Console Aux RJ45 RS232 Serial Port Pinout The table below summarizes the console aux RJ45 RS232 serial port pinout Table 19 Console Aux RJ45 RS232 seri...

Страница 170: ... 16 T1 E1 Interface Pinouts JackPin TelcoRX Signal Name Board Pins JackPin Telco TX Signal Name BoardPIns Line 4 39 RX_RING_P1 92 1 39 TX_RING_P1 88 Line 0 5 14 RX_TIP_P1 42 2 14 TX_TIP_P1 38 4 38 RX_RING_P2 91 1 38 TX_RING_P2 87 Line 1 5 13 RX_TIP_P2 41 2 13 TX_TIP_P2 37 4 35 RX_RING_P3 80 1 35 TX_RING_P3 76 Line 2 5 10 RX_TIP_P3 30 2 10 TX_TIP_P3 26 4 34 RX_RING_P4 79 1 34 TX_RING_P4 75 Line 3 5...

Страница 171: ...1 27 TX_RING_P11 52 Line 10 5 2 RX_TIP_P11 6 2 2 TX_TIP_P11 2 4 26 RX_RING_P12 55 1 26 TX_RING_P12 51 Line 11 5 1 RX_TIP_P12 5 2 1 TX_TIP_P12 1 4 33 RX_RING_P13 70 1 33 TX_RING_P13 74 Line 12 5 8 RX_TIP_P13 20 2 8 TX_TIP_P13 24 4 32 RX_RING_P14 69 1 32 TX_RING_P14 73 Line 13 5 7 RX_TIP_P14 19 2 7 TX_TIP_P14 23 4 29 RX_RING_P15 58 1 29 TX_RING_P15 62 Line 14 5 4 RX_TIP_P15 8 2 4 TX_TIP_P15 12 4 28 ...

Страница 172: ...rd PIns Line Board Connector 4 39 RX_RING_P0 66 1 39 TX_RING_P0 48 Line 0 PORTS 0 15 5 14 RX_TIP_P0 32 2 14 TX_TIP_P0 14 4 38 RX_RING_P1 65 1 38 TX_RING_P1 47 Line 1 5 13 RX_TIP_P1 31 2 13 TX_TIP_P1 13 4 35 RX_RING_P2 62 1 35 TX_RING_P2 44 Line 2 5 10 RX_TIP_P2 28 2 10 TX_TIP_P2 10 4 34 RX_RING_P3 61 1 34 TX_RING_P3 43 Line 3 5 9 RX_TIP_P3 27 2 9 TX_TIP_P3 9 4 41 RX_RING_P4 68 1 41 TX_RING_P4 50 L...

Страница 173: ... Line 10 5 2 RX_TIP_P10 20 2 2 TX_TIP_P10 2 4 26 RX_RING_P11 53 1 26 TX_RING_P11 35 Line 11 5 1 RX_TIP_P11 19 2 1 TX_TIP_P11 1 4 33 RX_RING_P12 60 1 33 TX_RING_P12 42 Line 12 5 8 RX_TIP_P12 26 2 8 TX_TIP_P12 8 4 32 RX_RING_P13 59 1 32 TX_RING_P13 41 Line 13 5 7 RX_TIP_P13 25 2 7 TX_TIP_P13 7 4 29 RX_RING_P14 56 1 29 TX_RING_P14 38 Line 14 5 4 RX_TIP_P14 22 2 4 TX_TIP_P14 4 4 28 RX_RING_P15 55 1 28...

Страница 174: ...3 1 36 TX_RING_P23 45 Line 23 5 11 RX_TIP_P23 29 2 11 TX_TIP_P23 11 4 31 RX_RING_P24 58 1 31 TX_RING_P24 40 Line 24 5 6 RX_TIP_P24 24 2 6 TX_TIP_P24 6 4 30 RX_RING_P25 57 1 30 TX_RING_P25 39 Line 25 5 5 RX_TIP_P25 23 2 5 TX_TIP_P25 5 4 27 RX_RING_P26 54 1 27 TX_RING_P26 36 Line 26 5 2 RX_TIP_P26 20 2 2 TX_TIP_P26 2 4 26 RX_RING_P27 53 1 26 TX_RING_P27 35 Line 27 5 1 RX_TIP_P27 19 2 1 TX_TIP_P27 1 ...

Страница 175: ...l Figure 99 32 T1 E1 Wiring Schematic of Cable between 32 T1 E1 Interface and Patch Panel 8 T1 E1 Interface Module RJ48C Port Pinnouts Table 22 RJ48C Connector Pin out for 8 T E1 Interface Module Description Direction Signal Pin Receive Tip Input RX_TIP 1 Receive Ring Output RX_RING 2 Not Connected 3 Receive Tip Input TX_TIP 4 Receive Ring Output TX_RING 5 Not Connected 6 Not Connected 7 Not Conne...

Страница 176: ... Tip Port 10 43 RX Ring Port 10 11 RX Tip Port 11 44 RX Ring Port 11 12 RX Tip Port 12 45 RX Ring Port 12 13 RX Tip Port 13 46 RX Ring Port 13 14 RX Tip Port 14 47 RX Ring Port 14 15 RX Tip Port 15 48 RX Ring Port 15 16 RX Tip Port 16 49 RX Ring Port 16 17 RX Tip Port 17 50 RX Ring Port 17 18 RX Tip Port 18 51 RX Ring Port 18 19 RX Tip Port 19 52 RX Ring Port 19 20 RX Tip Port 20 53 RX Ring Port 2...

Страница 177: ...ng Port 28 5 RX Tip Port 29 38 RX Ring Port 29 6 RX Tip Port 30 39 RX Ring Port 30 7 RX Tip Port 31 40 RX Ring Port 31 8 RX Tip Port 32 41 RX Ring Port 32 9 RX Tip Port 33 42 RX Ring Port 33 10 RX Tip Port 34 43 RX Ring Port 34 11 RX Tip Port 35 44 RX Ring Port 35 12 RX Tip Port 36 45 RX Ring Port 36 13 RX Tip Port 37 46 RX Ring Port 37 14 RX Tip Port 38 47 RX Ring Port 38 15 RX Tip Port 39 48 RX ...

Страница 178: ...30 Open 63 Open 31 Open 64 Open 32 Table 25 Port 0 23 TX Signal Pin Signal Name Pin Number TX Tip Port 0 33 TX Ring Port 0 1 TX Tip Port 1 34 TX Ring Port 1 2 TX Tip Port 2 35 TX Ring Port 2 3 TX Tip Port 3 36 TX Ring Port 3 4 TX Tip Port 4 37 TX Ring Port 4 5 TX Tip Port 5 38 TX Ring Port 5 6 TX Tip Port 6 39 TX Ring Port 6 7 TX Tip Port 7 40 TX Ring Port 7 8 TX Tip Port 8 41 TX Ring Port 8 9 TX ...

Страница 179: ...9 20 TX Tip Port 20 53 TX Ring Port 20 21 TX Tip Port 21 54 TX Ring Port 21 22 TX Tip Port 22 55 TX Ring Port 22 23 TX Tip Port 23 56 TX Ring Port 23 24 Open 57 Open 25 Open 58 Open 26 Open 59 Open 27 Open 60 Open 28 Open 61 Open 29 Open 62 Open 30 Open 63 Open 31 Open 64 Open 32 Table 26 Port 24 47 TX Signal Pin Signal Name Pin Number TX Tip Port 24 33 TX Ring Port 24 1 TX Tip Port 25 34 TX Ring ...

Страница 180: ...ort 37 14 TX Tip Port 38 47 TX Ring Port 38 15 TX Tip Port 39 48 TX Ring Port 39 16 TX Tip Port 40 49 TX Ring Port 40 17 TX Tip Port 41 50 TX Ring Port 41 18 TX Tip Port 42 51 TX Ring Port 42 19 TX Tip Port 43 52 TX Ring Port 43 20 TX Tip Port 44 53 TX Ring Port 44 21 TX Tip Port 45 54 TX Ring Port 45 22 TX Tip Port 46 55 TX Ring Port 46 23 TX Tip Port 47 56 TX Ring Port 47 24 Open 57 Open 25 Open...

Страница 181: ...3_TIP 6 TX_PORT44_RING TX_PORT28_RING TX_PORT12_RING 7 TX_PORT44_TIP TX_PORT28_TIP TX_PORT12_TIP 8 TX_PORT43_RING TX_PORT27_RING TX_PORT11_RING 9 TX_PORT43_TIP TX_PORT27_TIP TX_PORT11_TIP 10 TX_PORT42_RING TX_PORT26_RING TX_PORT10_RING 11 TX_PORT42_TIP TX_PORT26_TIP TX_PORT10_TIP 12 TX_PORT41_RING TX_PORT25_RING TX_PORT9_RING 13 TX_PORT41_TIP TX_PORT25_TIP TX_PORT9_TIP 14 TX_PORT40_RING TX_PORT24_...

Страница 182: ...RT31_RING RX_PORT15_RING 35 RX_PORT47_TIP RX_PORT31_TIP RX_PORT15_TIP 36 RX_PORT46_RING RX_PORT30_RING RX_PORT14_RING 37 RX_PORT46_TIP RX_PORT30_TIP RX_PORT14_TIP 38 RX_PORT45_RING RX_PORT29_RING RX_PORT13_RING 39 RX_PORT45_TIP RX_PORT29_TIP RX_PORT13_TIP 40 RX_PORT44_RING RX_PORT28_RING RX_PORT12_RING 41 RX_PORT44_TIP RX_PORT28_TIP RX_PORT12_TIP 42 RX_PORT43_RING RX_PORT27_RING RX_PORT11_RING 43 ...

Страница 183: ...G RX_PORT3_RING 61 RX_PORT35_TIP RX_PORT19_TIP RX_PORT3_TIP 62 RX_PORT34_RING RX_PORT18_RING RX_PORT2_RING 63 RX_PORT34_TIP RX_PORT18_TIP RX_PORT2_TIP 64 RX_PORT33_RING RX_PORT17_RING RX_PORT1_RING 65 RX_PORT33_TIP RX_PORT17_TIP RX_PORT1_TIP 66 RX_PORT32_RING RX_PORT16_RING RX_PORT0_RING 67 RX_PORT32_TIP RX_PORT16_TIP RX_PORT0_TIP 68 The table below summarizes the 3G patch panel pinouts of the con...

Страница 184: ...13 DS1 TX_PORT9_TIP 14 DS1 TX_PORT8_RING 15 DS1 TX_PORT8_TIP 16 17 18 DS1 TX_PORT7_RING 19 DS1 TX_PORT7_TIP 20 DS1 TX_PORT6_RING 21 DS1 TX_PORT6_TIP 22 DS1 TX_PORT5_RING 23 DS1 TX_PORT5_TIP 24 DS1 TX_PORT4_RING 25 DS1 TX_PORT4_TIP 26 DS1 TX_PORT3_RING 27 DS1 TX_PORT3_TIP 28 DS1 TX_PORT2_RING 29 DS1 TX_PORT2_TIP 30 DS1 TX_PORT1_RING 31 Cisco ASR 907 Router Hardware Installation Guide 174 Troublesho...

Страница 185: ... DS3 RX_PORT12_RING 41 DS3 RX_PORT12_TIP 42 DS1 RX_PORT11_RING 43 DS1 RX_PORT11_TIP 44 DS1 RX_PORT10_RING 45 DS1 RX_PORT10_TIP 46 DS1 RX_PORT9_RING 47 DS1 RX_PORT9_TIP 48 DS1 RX_PORT8_RING 49 DS1 RX_PORT8_TIP 50 51 52 DS1 RX_PORT7_RING 53 DS1 RX_PORT7_TIP 54 DS1 RX_PORT6_RING 55 DS1 RX_PORT6_TIP 56 DS1 RX_PORT5_RING 57 DS1 RX_PORT5_TIP 58 Cisco ASR 907 Router Hardware Installation Guide 175 Troubl...

Страница 186: ...d with the cable types specified in Connecting Serial Cables DB 9 Connector Pinouts The table below summarizes the pinouts for each serial interface type when using a DB 9 connector Table 29 DB 9 Pin outs IRIG B RS 485 Description Direction Standard DB 9 Pin NC NC Unused Output NC 1 NC NC Receive Input RxD 2 IRIG B RS232 IRIG B RS232 Transmit Output TxD 3 IRIG B RS485 TxD DTR Output DTR 4 GND GND ...

Страница 187: ...l interface type when using an RJ 45 connector Table 30 RJ45 Pinout IRIG B RS 485 Description Direction Standard DB 9 Pin NC RxD RS485 Ready to send Input RTS 1 NC RxD RS485 DTR Input DTR 2 NC NC Transmit Input TxD 3 Gnd Gnd Signal ground GND 4 Gnd Gnd Signal ground GND 5 IRIG B RS232 IRIG B RS232 Receive data Output RxD 6 IRIG B RS485 TxD DSR Output DST 7 IRIG B RS485 TxD CTS Output CTS 8 Twisted...

Страница 188: ...ors on the Cisco 2 port T1 E1 RAN interface card for both the shielded and unshielded cables for either T1 or E1 Figure 100 RJ 48C Connector Wiring Cisco recommends using a shielded cable for your RJ 48C connectors Note Unshielded Shielded Description Pin Description Pin Receive Ring 1 Receive Ring 1 Receive Tip 2 Receive Tip 2 3 Receive Shield 3 Transmit Ring 4 Transmit Ring 4 Transmit Tip 5 Tran...

Страница 189: ...P2 6 TRP3 7 TRP3 8 USB Console Port Pinout Two individual Type A USB connector are used for USB console and USB mass storage One single USB 2 0 Type A receptacle is provided on the RSP front panel for providing console access to ROMMON IOS XE and diagnostics It operates as a USB peripheral only for connection to an external host PC This requires the use of a Type A to Type A connector instead of a...

Страница 190: ... Flash MEM Port Pinout The table below summarizes the USB flash MEM port pinout Table 32 Single USB Flash MEM Port Description Direction Signal Name Pin 5VDC 500mA Vcc A 1 Data D A 2 Data D A 3 Ground Gnd A 4 USB TYPE A receptacle used Note The USB flash MEM port 5VDC is output We provide power for USB flash MEM and it operates as a USB host device Note Fiber Optic Specifications The specification...

Страница 191: ...ple fans In the event that a single fan fails the Cisco ASR 907 Router software adjusts the fan speed to prevent excessive heat within the chassis Note ASR900 RSP LED Table 33 RSP LEDs Description two LEDs for each port Color State LED Disabled no power to RSP Off Power PWR Power rails on RSP in range Green Disabled power down Off Status STAT Failure to boot lit at reset Red Rommon booted Yellow I...

Страница 192: ... the board PWR and overall router health STAT status During power up state these LEDs provide booting status and report errors The digital code signing functionality validates the integrity and authenticity of the ROMMON image before booting it Note Table 34 ASR900 RSP3A 400 W LED Comment Indication STAT LED State PWR LED State Image validation failed System is in hung state Power is OK and the fi...

Страница 193: ...now controls the STAT LED IOS is successfully booted Off Green Interface Module LEDs The LED summary applies to the following interface modules SFP Gigabit Ethernet Interface Module RJ45 Gigabit Ethernet Interface Module XFP 10 Gigabit Ethernet XFP Interface Module 8x1 Gigabit Ethernet SFP 1x10 Gigabit Ethernet SFP Interface Module 8x1 Gigabit Ethernet RJ45 1x10 Gigabit Ethernet SFP Interface Modu...

Страница 194: ...Green 1 Port OC 192 or 8 Port Low Rate CEM Interface Module LEDs The table summarizes the LEDs for the 1 Port OC 192 or 8 Port Low Rate CEM Interface Module Meaning Default Off Color State LED All power rails are within spec Green Power PWR Disabled Red No power to IM Off Operational Green Operating Status STAT Failure Red Disabled or power down Off Link Up Solid Green SFP Link Left LED Link Activ...

Страница 195: ...d Mode Right LED OTN FLASH Green SONET or SDH Solid Yellow RFU FLASH Yellow No Link Off 48 T1 E1 and 48 T3 E3 Interface Module LEDs The table summarizes the LEDs for the 48 T1 E1 and 48 T3 E3 interface module Meaning Default Off Color State LED All power rails are within spec Green Power PWR Disabled Red No power to Interface Module Off Operational Green Operating Status STAT Booting FLASH Green F...

Страница 196: ...e table below summarizes the LEDs for the OC 3 interface module Table 36 Interface Module LEDs Description Color State LED Disabled no power to IM Off Power PWR Enabled and power rails on IM in range Green Disabled power down Off Status STAT Failure on at reset Red Booting if local CPU Amber Operational Green SFP receiving good remote signal Green Carrier Alarm C A Remote or local alarm activated ...

Страница 197: ... a loopback state Blinking amber All ports disabled or shut down Off All power rails are within supported range Green PWR Disabled Red No power on the interface module Off Failed Red STAT Disabled or powered down Off Booting Blinking red Active Green The table below summarizes the LEDs for the 8 T1 E1 interface module Table 38 8 T1 E1 Interface Module LEDs Description two LEDs for eachT1 E1 port C...

Страница 198: ...The table below summarizes the LEDs for the 32 T1 E1 interface module Table 39 32 T1 E1 Interface Module LEDs Description two LEDs for eachT1 E1 port Color State LED Active Green Active Standby Blinking green Operationally down card is disabled or shut down Off All ports up Solid Green Port All ports up and one or more ports in a loopback state Blinking green One or more configured ports are down ...

Страница 199: ...reen No Power Off At least one of the 4 ports is in an up state Green 68 Pin Connector LEDs At least one of the 4 ports is passing traffic Blinking Green All four ports are successfully initialized and in a down state Solid Yellow At least one of the port has failed Blinking Yellow All the ports are not enabled at POR Off Port is passing traffic Green 12 in 1 Connector LEDs Port successfully initi...

Страница 200: ...led Blinking Red Fan Tray LEDs The table below summarizes the fan tray LEDs Table 42 Fan Tray LEDs Description Color State LED Disabled power down Off Status TEMP Over temperature Amber OK Green Fan rotation in range Green Fan FAN Fan fault Amber Two or more fan faults Red No minor alarm Off Minor MIN Minor alarm Amber No major alarm Off Major MAJ Major alarm Red No critical alarm Off Critical CRI...

Страница 201: ...ry Alarm Meaning Alarm Type RSP OIR Critical Power supply OIR Port in down state Environmental sensor threshold exceeded voltage temperature IM OIR IM crash Standby RSP in ROMmon mode Major RSP removed RSP failure Port administratively shut down Info Cisco ASR 907 Router Hardware Installation Guide 191 Troubleshooting Alarm Conditions ...

Страница 202: ...Cisco ASR 907 Router Hardware Installation Guide 192 Troubleshooting Alarm Conditions ...

Страница 203: ...e each task Upgrade removal and maintenance procedures Use the Site Log as a record of ongoing router maintenance and expansion history Each time a task is performed on the Cisco ASR 907 Router update the Site Log to reflect the following Removal or replacement of interface modules fan tray power supplies or RSPs Configuration changes Maintenance schedules and requirements Maintenance procedures p...

Страница 204: ...sco ASR 907 router Table 45 Manufactures Products Model Web Site or Phone Number Manufacturer Air Plenum Foxconn Technology Group Website www foxconn com Foxconn Lugs http www burndy com Burndy Cisco ASR 907 Router Hardware Installation Guide 194 Site Log and Manufactures Manufactures ...

Отзывы: