synthetic loss calculation packets
To configure the number of packets that must be used to calculate each Frame Loss Ratio (FLR) calculation,
use the
synthetic loss calculation packets
command in the Ethernet SLA profile probe configuration mode.
synthetic loss calculation packets number
Syntax Description
Specifies the number of packets that must be used to calculate each FLR. The range is 10
–
12096000.
The value must be a divisor of the number of packets per probe. If bursts are
configured, the value must be a multiple of the number of packets per burst.
Note
number
Command Default
The default value is the number of packets in the probe, that is each probe results in a single FLR calculation.
Command Modes
SLA profile probe configuration (config-sla-prof-pb)
Command History
Modification
Release
This command was introduced.
Release 4.3.0
Usage Guidelines
To use this command, you must be in a user group associated with a task group that includes appropriate task
IDs. If the user group assignment is preventing you from using a command, contact your AAA administrator
for assistance.
The
synthetic loss calculation packets
command can only be configured for packet types that support synthetic
loss measurement.
An FLR value is calculated for each discrete block of packets. For instance, if a value of 10 is configured,
then the first FLR value is calculated based on packets 0 to 9, the second FLR value is calculated based
on packets 10 to 19, and so on.
Note
Task ID
Operation
Task ID
read, write
ethernet-services
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x
409
Ethernet OAM Commands on the Cisco ASR 9000 Series Router
synthetic loss calculation packets