Description
Field
Values of the following alarm soaking intervals:
•
Alarm declarings: amount of time, in
milliseconds, after which an alarm is declared.
•
Alarm clearing: amount of time, in milliseconds,
after which an alarm is cleared.
Alarm Soaking Interval
Indicates controller port on which BERT test can be
run.
Bert Test on controller port
Indicates the current state of the test. Can be one of
the following:
•
running
—
BER test is still in progress.
•
done
—
BER test is complete.
•
not running
—
BER test is not running on the
controller.
BERT test result
Indicates the test pattern you selected for the test.
Test Pattern
Indicates the current synchronization state (sync).
Status
Indicates the number of times synchronization has
been detected during this test.
Sync Detected
Indicates the length of the test.
Interval
Indicates the time remaining for the test to run.
If you terminate a BER test, you receive a
message similar to the following: Time
Remain : 2 minute(s) (unable to complete)
"(Unable to complete)" signifies that you
interrupted the test.
Note
Time Remain
Bit errors that have been detected since the test
started.
Bit Errors (since BERT started)
Total number of test bits that have been received since
the test started.
Bits Received (since BERT started)
Bit errors that have been detected since the
synchronization started.
Bit Errors (since last sync)
Total number of test bits that have been received since
the synchronization started.
Bits Received (since last sync)
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x
1049
T3, E3, T1, E1 Controller Commands on the Cisco ASR 9000 Series Router
show controllers t1