cablelength
To specify the distance of the cable from the routers to the network equipment, use the
cablelength
command
in T3 or E3 configuration mode. To restore the default cable length, use the
no
form of this command.
cablelength feet
no cablelength
Syntax Description
Number of feet in the range from 0 to 450. The default is 224 feet.
feet
Command Default
The default is 224 feet.
Command Modes
T3 configuration
E3 configuration
Command History
Modification
Release
This command was introduced.
Release 3.9.0
Support for E3 configuration mode was added.
Release 4.0.0
Usage Guidelines
To use this command, you must be in a user group associated with a task group that includes appropriate task
IDs. If the user group assignment is preventing you from using a command, contact your AAA administrator
for assistance.
You can specify a cable length from 0 to 450 feet; however, the hardware recognizes only two ranges: 0 to 49
and 50 to 450. For example, entering 35 feet uses the 0 to 49 range. If you later change the cable length to 40
feet, there is no change because 40 is still within the 0 to 49 range. However, if you change the cable length
to 50, the 50 to 450 range is used. The actual number you enter is stored in the configuration file.
Task ID
Operations
Task ID
read, write
sonet-sdh
Examples
The following example shows how to set the cable length for the router to 300 feet:
RP/0/RSP0/CPU0:router(config)#
controller t3 0/6/0/0
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x
955
T3, E3, T1, E1 Controller Commands on the Cisco ASR 9000 Series Router
cablelength