![Cisco ASR 9000 Series Скачать руководство пользователя страница 259](http://html.mh-extra.com/html/cisco/asr-9000-series/asr-9000-series_command-reference-manual_64844259.webp)
ethernet sla on-demand operation type
cfm-synthetic-loss-measurement probe
To execute an on-demand Ethernet SLA operation probe for CFM synthetic loss measurement, use the
ethernet
sla on-demand operation type cfm-synthetic-loss-measurement probe
command in EXEC mode.
ethernet sla on-demand operation type cfm-synthetic-loss-measurement probe
[
priority number
] [
send
{
packet
{
once
|
every number
{
milliseconds| seconds| minutes| hours
}}|
burst
{
once
|
every number
{
seconds| minutes| hours
}}}
packet count number interval number
{
milliseconds| seconds
}]
synthetic
loss calculation packets number
[
packet size bytes
[
test pattern hex 0x HHHHHHHH
] ]
domain
domain_name source interface type interface-path-id target
{
mac-address H
.
H
.
H
.
H
|
mep-id id_number
}
[
statistics measure
{
one-way-loss-sd| one-way-loss-ds
} [
aggregate
{
none
|
bins number width count
}]
[
buckets
{
archive number
|
size number
{
per-probe| probes
}}] ] [
schedule
{
now
|
at hh
:
mm
[.
ss
] [
day
[
month
[
year
]]]|
in number
{
seconds| minutes| hours
}} [
for duration
{
seconds| minutes| hours
}] [
repeat every
number
{
seconds| minutes| hours
}
count probes
]]
[asynchronous]
Syntax Description
(Optional) Configures the priority of outgoing SLA
probe packets. The range is 0 to 7. The default is
to use the COS bits for the egress interface.
priority number
(Optional) Sends one packet one time.
send packet once
(Optional) Sends one packet every specified number
of milliseconds, seconds, minutes, or hours, where
number
is in the following range:
•
1 to 3600
seconds
•
1 to 1440
minutes
•
1 to 168
hours
•
100 to 10000
milliseconds
(specified in
increments of 100)
send packet every number
{
milliseconds
|
seconds
|
minutes
|
hours
}
(Optional) Specifies that a burst of packets is sent
one time. This is the default.
send burst once
(Optional) Sends a burst of packets every specified
number of seconds, minutes, or hours, where
number
is in the following range:
•
1
–
3600
seconds
•
1
–
1440
minutes
•
1
–
168
hours
The default is to send a burst every 10 seconds.
send burst every number
{ |
seconds
|
minutes
|
hours
}
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x
239
Ethernet OAM Commands on the Cisco ASR 9000 Series Router
ethernet sla on-demand operation type cfm-synthetic-loss-measurement probe