frame-seconds threshold
To configure the thresholds that trigger a frame-seconds error event, use the
frame-seconds threshold
command in Ethernet OAM link monitor or interface Ethernet OAM link monitor configuration mode. To
return the threshold to the default value, use the
no
form of this command.
frame-seconds threshold low threshold
[
high threshold
]
no frame-seconds threshold low threshold
[
high threshold
]
Syntax Description
Low threshold, in seconds, that triggers a frame-seconds error event. The range
is 0 to 900.
low threshold
(Optional) High threshold, in seconds, that triggers a frame-seconds error event.
The range is 1 to 900. The high threshold value can be configured only in
conjunction with the low threshold value.
high threshold
Command Default
The default value is 1.
Command Modes
Ethernet OAM link monitor configuration (config-eoam-lm)
Interface Ethernet OAM link monitor configuration (config-if-eoam-lm)
Command History
Modification
Release
This command was introduced.
Release 3.9.0
Usage Guidelines
To use this command, you must be in a user group associated with a task group that includes appropriate task
IDs. If the user group assignment is preventing you from using a command, contact your AAA administrator
for assistance.
When the low threshold is passed, a frame-seconds error event notification is generated and transmitted to
the OAM peer. Additionally, any registered higher level OAM protocols, such as Connectivity Fault
Management (CFM), are also notified. When the high threshold is passed, the configured high threshold action
is performed in addition to the low threshold actions. The high threshold is optional and is configurable only
in conjunction with the low threshold.
Task ID
Operations
Task ID
read, write
ethernet-services
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x
252
Ethernet OAM Commands on the Cisco ASR 9000 Series Router
frame-seconds threshold