Maintenance
Roadster & Mirage S+/HD User Manual
4-7
020-100002-04 Rev. 1 (12-2008)
1.
TURN THE LAMP OFF
Press
(power) to turn the lamp off. Allow the cooling fans to stop
automatically (within approximately five minutes) before proceeding with Step 2.
This wait period is also required to allow the lamp to sufficiently cool before
handling.
2.
UNPLUG THE PROJECTOR
When the cooling fans have stopped, turn the projector’s main switch off, and
unplug.
WARNING
Always power down and unplug the projector prior to servicing.
Allow the lamps to cool before handling
3.
OPEN THE LAMP DOOR
WARNING
Protective gear required. Wear a face
shield.
Using a #2 Phillips screwdriver, loosen
the ¼-turn lock screws (2) securing the
lamp door, which is located at the rear of
the projector below the input panel. See
Figure 4.2.
4.
REMOVE LAMP RETAINING BAR
Remove the two (2) screws that secure the retaining bar along the bottom edge of
the lamp module using a #2 Phillips screwdriver. See Figure 4.3. Swing the bar
aside—it is hinged on the left.
Figure 4.2. Open Lamp Door
Figure 4.3. Remove Retaining Bar