INST.No.INE-378-P9CE
- 49 -
10.3.2 Parameter programming/selection (engineering mode)
Parameter item
Sub
display
Parameter
Default
Paragraph
Analog output scaling
OutL or
OutH
OutL
: Minimum value
(0 to 6280ºC)
OutH
: Maximum value
(0 to 6280ºC)
Minimum value of
measuring range
Maximum value of
measuring range
6.5.1
Analog dummy output OutC
0
to
100
%
0%
6.5.2
Hold function
HoLd
no
: Hold function disable
PEAk
: Peak hold
SAMP
: Sample hold
no
6.5.3-1
Peak hold reset type
H.rSt
no
: Reset disable
In
: Internal - Time reset
Et
:External -Remote contact reset
no
6.5.3-2
Peak hold reset time
r.tim
0.0
to
99.9
seconds
0.0 second
6.5.3-3
Measurement unit
unit
C, F
C
6.5.4
Contact output
dout
no
: No contact output
ALM
: High/low temperature alarm
Err
: Self-diagnostic abnormal
ALM
6.5.5
Automatic emissivity
calculation
E.Aut
no
: Calculation disable
In
: Internal - Key
Et
: External – Analog input
no
6.5.6
Zero/span
adjustments
Zero
SPAn
(
0
to
6280º
C)
Minimum and
maximum value of
measuring range
6.5.7
Analog output
correction
CP.n
no
In
Out
End
Number of analog output
correction data :
0, 2
to
8
Analog output correction
data No.
:
1
to
8
Data before analog output
Correction :
0
to
6280
ºC
Data after analog output
Correction :
0
to
6280
ºC
Analog output correction programming
Cont
: Continuous entering
Canc
:Exit from
programming
Go
: Correction execution
0
1
0ºC
0ºC
cont
6.5.8-1
6.5.8-2
6.5.8-3
6.5.8-4
6.5.8-5
Analog input item for
IR-FA
□
5
□□
Ain
no
: Analog input disable
ErMt
: Remote emissivity
programming
Eaut
: Automatic emissivity
calculaiton
no
6.5.9-1
Emissivity scaling
AinL
AinH
Remote emissibity
programming:
=
0.001
to
1.999
0.050
~
1.999
6.5.9-2.
Temperature scaling
AinL
AinH
Automatic emissivity
calculatio:
Temp =
0
to
6280
ºC
Minimum and
maximum value of
measuring range
6.5.9-3
Communications
Adr
SPd
Address
: 1 to 32
Communications speed :
4.8
… 4800bps
9.6
… 9600bps
19.2
…19200bps
1
9.6
6.5.10