SECTION 1
GENERAL
The installation of a bleed air cabin heater will assist the exhaust heat
exchanger in cabin heating for extremely cold conditions. Compressor
discharge air which is taken from a fitting on the compressor scroll is
routed through a manually operated shut-off valve to an infuser that
mixes the bleed air with fresh air and exhaust heater air. To provide this
capability, the following items are installed:
1. Compressor discharge fittings, lines and shut-off valve
assembly.
2. Bleed air heater infuser system.
3. Fresh air inlet shunt and ducting.
SECTION 2
LIMITATIONS
Due to the possible damage if the windshield, the maximum OAT for
bleed air operation is +50°F (10°C)
PLACARD
BLEED AIR
HEATER
PULL ON
Do not operate above
50
°
F (10
°
C)