![Cessna 206H Скачать руководство пользователя страница 172](http://html1.mh-extra.com/html/cessna/206h/206h_flight-manual_2584512172.webp)
SOLOY TURBINE PAC
SECTION 8
POHS CESSNA T206H/206H
HANDLING, SERVICE &
MAINTENANCE
8-8
F.A.A. Approved
November 17, 2015
CAUTION
USE OF OILS THAT ARE NOT INCLUDED IN
THE APPROVED OILS LISTING, OR FAILURE
TO DRAIN OIL WITHIN THE PRESCRIBED
INTERVAL WILL BE CONSIDERED AS MISUSE
UNDER THE WARRANTY POLICY.
REFER TO THE MAINTENANCE MANUALS
FOR
THE
COMPLETE
OIL
SYSTEM
MAINTENANCE SCHEDULE.
OIL LEVEL CHECK
Check oil level within 15 minutes of shutdown. Normal operating
range on the oil dipstick is four to six U.S. quarts in the tank.
FUEL
PRIMARY FUELS
MIL-T-5624
JP-5
MIL-T-83133
JP-8
ASTMD-1655
JET A or A1
JP-1 Fuel conforming to ASTM D-1655, Jet A
Diesel #1 fuel conforming to ASTM D-1655, Jet A
CAUTION
TO
PREVENT
ENGINE
FUEL
SYSTEM
CONTAMINATION WHICH COULD CAUSE
ENGINE FLAME OUT, AN EXTERNAL LOW
PRESSURE FUEL FILTER SHOULD BE USED
ON
ANY
AIRCRAFT
REFUELING
FROM
REMOTE REFUELING SITES (DRUMS, ETC.).
FUEL CAPACITY
–
No Change
UNCONTROLLED
COPY