![Cessna 206H Скачать руководство пользователя страница 171](http://html1.mh-extra.com/html/cessna/206h/206h_flight-manual_2584512171.webp)
SOLOY TURBINE PAC
SECTION 8
POHS CESSNA T206H/206H
HANDLING, SERVICE &
MAINTENANCE
8-7
F.A.A. Approved
November 14, 2014
WARNING
ALTHOUGH MIL-PRF-23699, SAE AS5780,
DOD-PRF-85734 OR MIL-PRF-7808G OIL IS
ACCEPTABLE, DO NOT MIX THESE OILS.
ONLY DISCRETIONARY MIXING OF OILS IS
PERMITTED WITHOUT A TIME PENALTY. USE
OF MIXED OILS FROM DIFFERENT SERIES IN
AN ENGINE IS LIMITED TO FIVE HOURS
TOTAL
RUNNING
TIME
DURING
ONE
OVERHAUL
PERIOD.
ADEQUATE
MAINTENANCE
RECORDS
MUST
BE
MAINTAINED TO ENSURE THAT THE FIVE
HOUR LIMIT IS NOT EXCEEDED. FAILURE TO
COMPLY WITH OIL MIXING RESTRICTIONS
CAN RESULT IN ENGINE FAILURE.
FAILURE
TO
COMPLY
WITH
MIXING
RESTRICTIONS CAN RESULT IN ENGINE
FAILURE.
TO DECREASE THE LIKELYHOOD OF CARBON
OR COKE DEPOSITS BEING DISLODGED
DURING
THE
CHANGE-
OVER
TO
“3
RD
GENERATION” OILS. THESE CHANGE-OVERS
SHOULD ONLY BE MADE WHEN THE ENGINE
IS NEW OR REPAIRED, TO THE EXTENT THE
LUBRICATION PASSAGES AND SUMPS HAVE
BEEN CLEANED AND FLUSHED.
WHILE CONCIDERABLE LABORATORY DATA
IS AVAILABLE TO DEMONSTRATE THE
COMPATABILITY
OF
ONE
SYNTHETIC
TURBINE OIL WITH OTHER TURBINE OILS
MEETING THE SAME SPECIFICATION, THE
INDISCRIMINATE MIXING OF APPROVED OILS
DURING THE OPERATIONAL USE OF THE OIL
IS
NOT
RECOMMENDED.
HOWEVER
EMERGENCY
TOP-OFF,
INADVERTENT
MIXING OR CHANGE-OVER TO A DIFFERENT
BRAND IS ACCEPTABLE.
OIL DRAIN PERIOD
It is recommended that the oil be changed every 200 hours or six
months, whichever comes first.
UNCONTROLLED
COPY