4.
Set Mode:
CNC 12 can either be in velocity or precision mode.
•
Go to the parameters menu (From the main menu press
F1 Setup → F3 Config.
Password
137
.
Press
F3 Parms.
)
◦
If using velocity mode (Estun Drive):
Set parameter
256 to 1
.
◦
If using precision mode (Yaskawa or Delta Drive):
Set parameter
256 to 2
.
5.
Verify Heating / Cooling Parameters:
Heating and cooling do not apply for 3
rd
party drives.
Go to the parameters menu. (From the main menu press
F1 Setup → F3 Config.
Password
137
.
Press
F3 Parms.
)
Set parameters
21- 24
to
0
and
132 – 135
to
0
.
Make sure the cooling coefficients (parameters
25 – 28
and
236 – 239
) are set to their default value of “
0.68
”.
Press
F10
to save when finished.
Figure 6.1.2
Setting up the Drive Output
and Encoders
Figure 6.1.3
Heating Coefficients
Disabled
Axis 1
Axis 2
Axis 3
Axis 4
Encoder 1
Encoder 2
Encoder 3
Encoder 4
Spindle Encoder
These parameters set
at 1 mean the drive
plugged into the axis 1
header will correspond
with the first axis from
Figure 6.1.1
Содержание 13126
Страница 1: ...CENTROID Oak Board Install Manual Last revised 6 3 2021 Page 1 of 86...
Страница 10: ...1 3 OVERVIEW Page 10 of 86 Chapter 1 What s included...
Страница 22: ...Page 22 of 86 Chapter 3 Software Installation...
Страница 41: ...Page 41 of 86 Electrical Cabinet Wiring Figure 5 8 1 Sample VFD Wiring...
Страница 42: ...Page 42 of 86 Electrical Cabinet Wiring Figure 5 8 2 Spindle Wiring...
Страница 63: ...APPENDIX B TECHNICAL INFORMATION...
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......
Страница 70: ......
Страница 71: ......
Страница 72: ......
Страница 73: ......
Страница 74: ......
Страница 75: ......
Страница 76: ......
Страница 77: ......
Страница 78: ......
Страница 79: ......
Страница 80: ......
Страница 81: ......
Страница 82: ......
Страница 83: ...APPENDIX C 3RD PARTY DRIVE CABLE INFORMATION Yaskawa Drives Page 83 of 86 Appendices...
Страница 84: ...Delta Drives Page 84 of 86 Appendices...
Страница 85: ...Estun Pronet Series Page 85 of 86 Appendices...
Страница 86: ...Flying Lead Cable Page 86 of 86 Appendices...