CD3 Products Manual
CD3, General Benefit Corporation |
| 612.467.9441
Patent
Pending | Made in USA | © 2019
42
4.
Always only connect the positive (+) cable to the positive terminal and the negative
(-) cable to the negative terminal. Reversing polarity is very dangerous.
5.
Never smoke or allow a spark or flame in the vicinity of the batteries.
6.
Be extra cautious to reduce risk of dropping a metal tool onto battery. It might
spark or short-circuit battery or other electrical part that may cause explosion.
7.
Remove personal metal items such as rings, bracelets, necklaces, and watches when
working with a battery. A lead acid battery can produce a short-circuit current high
enough to weld a jewelry such as a ring to another metal, causing a severe burn.
8.
Never charge a frozen battery.
9.
Do not lift a battery by the terminal posts, or internal damage may result.
4.4.2 Battery Pack Inspection
Warning! - Make sure power has been disconnected from the batteries prior to
inspection process.
*Note: The main battery shut-off does not remove power from the batteries. It only
can shut off battery power to the unit and stop current draw from them. The batteries
themselves will always still have energy in them.
4.4.2.1 Access
The Outpost unit will have the batteries right in front of the service door. The Wayside
120V and Wayside Solar will have the batteries visible to the right side of the unit when
accessed from the service door. The batteries are visible through the door, but for
further clear access, the rear panel will have to be removed. First, removed the door by
swinging it all the way open and lifting it up off the hinges. Then, remove the three
screws inside the door jam of the panel. Swing the panel out slightly and pull it away
from the unit. There are only tabs holding it in place on the opposite side.
4.4.2.2 What To Look For
Inspect for any loose connections by wiggling the top post battery cables where they
attach to the top of the battery. If you find any signs of a loose cable connection, they
must be tightened by a trained professional before the main power shut-off switch is
turned back on. Inspect for any acid spills or corrosion to the battery posts or cables. If
corrosion exists, the aluminum or metal components will turn white in color. All acid
and vulnerable metals must be cleaned appropriately by a trained professional before
the main power shut-off switch is turned back on. Reassemble all removed components