9.
Whipping hoses can cause serious injury. Always check for damaged or loose hoses
and fittings prior to use.
10.
If the air hose is severed or punctured for any reason push the “all off” button
immediately and do not reactivate the blower function until the hose is replaced.
Only push the “all off” button if it is safe to do so, a severed hose may make the air
hose move around or whip back and forth under the pressure. If this is the case, do
not approach the unit unless it is safe to do so. If necessary, let the time expire for
the operation.
3.4.3 Blower Button Operation
The orange light in the lighted blower actuation button
indicates that it is ready to operate. The blow gun will
become active instantly with the push of the actuation
button. Actuating the blower function will pressurize the
air hose for the blow gun, but not dispense any air by this
operation alone. The trigger on the blow gun itself will
need to be depressed to dispense pressurized air. Once
active, the button will begin to flash while the blower is
active (i.e. pressure to the air hose). The operation
window/timer is for two minutes, at which point the
blower will turn off. During the two minute operation
window the button will flash at a rate of about one
second on, one second off for the first one minute and 30 seconds. The button can be
pushed again at any time during this part of the operation window to turn it off. The
last 30 seconds of the time window the button light will flash at a rate of about one half
second on, one half second off. During this final 30 seconds, pushing the button again
will continue the operation of the blower and reset the operation for another two
minute time window. The operation can also be canceled by the “all off” red button at
any point during operation. Note that the cancelation of the blower function will still
leave air in the air hose if the blow gun trigger has not been depressed to relieve it. The
gun will still blow for a few seconds after that function has been canceled. If the button
light is flashing in a manner other than described above, it is a signal of a system fault.
Contact a qualified CD3 service person.
3.4.4 Blower Hose
The blower hose is a 35’ long, 3/8” diameter flexible rubber air hose. The hose should
be coiled on the provided hanger when not in use. This will prevent possible damage
from occurring such as a vehicle driving over it. Any hose that is broken, constricted,